Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours

被引:10
|
作者
Jordi Juan-Senabre, Xavier [3 ]
Lopez-Tarjuelo, Juan [3 ]
Conde-Moreno, Antonio [2 ]
Santos-Serra, Agustin [3 ]
Sanchez-Iglesias, Angel L. [2 ]
David Quiros-Higueras, Juan [3 ]
de Marco Blancas, Noelia [3 ]
Calzada-Feliu, Salvador [3 ]
Ferrer-Albiach, Carlos [1 ]
机构
[1] Consorcio Hosp Prov Castello, Inst Oncol, Inst Canc, ES-12002 Castellon De La Plana, Spain
[2] Consorcio Hosp Prov Castello, Inst Oncol, Dept Radiat Oncol, ES-12002 Castellon De La Plana, Spain
[3] Consorcio Hosp Prov Castello, Inst Oncol, Dept Med Phys, ES-12002 Castellon De La Plana, Spain
来源
CLINICAL & TRANSLATIONAL ONCOLOGY | 2011年 / 13卷 / 11期
关键词
Image-guided radiotherapy (IGRT); Systematic and random uncertainties; CTV to PTV margin; Prostate carcinoma; Head and neck carcinoma; SETUP ERROR; COMPUTED-TOMOGRAPHY; ONLINE CORRECTION; RADIOTHERAPY; MOTION; KILOVOLTAGE; INTRAFRACTION; LOCALIZATION; MANAGEMENT; PROTOCOL;
D O I
10.1007/s12094-011-0740-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To evaluate the magnitude of systematic and random errors from a subset of 100 prostate and 26 head and neck (H&N) cancer patients treated with conventional conformal radiotherapy and using image-guided radiotherapy (IGRT). After treatment, the uncertainties involved and the CTV to PTV margin were evaluated. An Elekta SynergyA (R) linear accelerator was used, taking advantage of 3D on-board computed tomography. IGRT with no-action level (NAL) protocol was applied, reporting the 3D translation and rotation corrections. A statistical study was performed to analyse systematic, random and interobserver uncertainties, and, finally, to obtain the CTV to PTV margins. The H&N patients' uncertainties found were smaller than those of prostate patients. The CTV to PTV margins assessed, following the guidelines found in the literature, in the three dimensions of space (right-left, superior-inferior, anterior-posterior) were (5.3, 3.5, 3.2) mm for H&N and (7.3, 7.0, 9.0) mm for prostate cancer treatments. It was found that assessing all the involved uncertainties within radiation treatments was very revealing; their quality improves using IGRT techniques and performing extensive data analysis.
引用
收藏
页码:819 / 825
页数:7
相关论文
共 15 条
  • [1] Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours
    Xavier Jordi Juan-Senabre
    Juan López-Tarjuelo
    Antonio Conde-Moreno
    Agustín Santos-Serra
    Ángel L. Sánchez-Iglesias
    Juan David Quirós-Higueras
    Noelia de Marco Blancas
    Salvador Calzada-Feliu
    Carlos Ferrer-Albiach
    Clinical and Translational Oncology, 2011, 13 : 819 - 825
  • [2] CTV to PTV margins for prostate irradiation. Three-dimensional quantitative assessment of interfraction uncertainties using portal imaging and serial CT scans
    Perez-Romasanta, Luis A.
    Lozano-Martin, Eva
    Velasco-Jimenez, Joaquin
    Mendicote-Leon, Fermin
    Sanz-Martin, Miguel
    Torres-Donaire, Javier
    Carrascosa-Fernandez, Carmen
    Zapata-Jimenez, Juan Carlos
    Arjona-Gutierrez, Jacinto
    Gil-Agudo, Antonio
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2009, 11 (09): : 615 - 621
  • [3] CTV to PTV margins for prostate irradiation. Three-dimensional quantitative assessment of interfraction uncertainties using portal imaging and serial CT scans
    Luis A. Pérez-Romasanta
    Eva Lozano-Martín
    Joaquín Velasco-Jiménez
    Fermín Mendicote-León
    Miguel Sanz-Martín
    Javier Torres-Donaire
    Carmen Carrascosa-Fernández
    Juan Carlos Zapata-Jiménez
    Jacinto Arjona-Gutiérrez
    Antonio Gil-Agudo
    Clinical and Translational Oncology, 2009, 11 : 615 - 621
  • [4] Is application of a quantitative CT technique helpful for quantitative measurement of bone density using dental cone-beam CT?
    Nishikawa, Keiichi
    Kousuge, Yuuji
    Sano, Tsukasa
    ORAL RADIOLOGY, 2016, 32 (01) : 9 - 13
  • [5] Intraoperative cone-beam CT for head and neck surgery: Feasibility of clinical implementation using a prototype mobile C-arm
    King, Emma
    Daly, Michael J.
    Chan, Harley
    Bachar, Gideon
    Dixon, Benjamin J.
    Siewerdsen, Jeffrey H.
    Irish, Jonathan C.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2013, 35 (07): : 959 - 967
  • [6] Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype
    Daly, M. J.
    Siewerdsen, J. H.
    Moseley, D. J.
    Jaffray, D. A.
    Irish, J. C.
    MEDICAL PHYSICS, 2006, 33 (10) : 3767 - 3780
  • [7] Evaluation of Dose Calculation Based on Cone-Beam CT Using Different Measuring Correction Methods for Head and Neck Cancer Patients
    Gong, Hanshun
    Liu, Bo
    Zhang, Gaolong
    Dai, Xiangkun
    Qu, Baolin
    Cai, Boning
    Xie, Chuanbin
    Xu, Shouping
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2023, 22
  • [8] A method to analyze the cord geometrical uncertainties during head and neck radiation therapy using cone beam CT
    Zeng, Grace G.
    Breen, Stephen L.
    Bayley, Andrew
    White, Elizabeth
    Keller, Harald
    Dawson, Laura
    Jaffray, David A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (02) : 228 - 230
  • [9] CONE-BEAM CT ASSESSMENT OF INTERFRACTION AND INTRAFRACTION SETUP ERROR OF TWO HEAD-AND-NECK CANCER THERMOPLASTIC MASKS
    Velec, Michael
    Waldron, John N.
    O'Sullivan, Brian
    Bayley, Andrew
    Cummings, Bernard
    Kim, John J.
    Ringash, Jolie
    Breen, Stephen L.
    Lockwood, Gina A.
    Dawson, Laura A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : 949 - 955
  • [10] Predicting response to radiotherapy of head and neck squamous cell carcinoma using radiomics from cone-beam CT images
    Sellami, S.
    Bourbonne, V
    Hatt, M.
    Tixier, F.
    Bouzid, D.
    Lucia, F.
    Pradier, O.
    Goasduff, G.
    Visvikis, D.
    Schick, U.
    ACTA ONCOLOGICA, 2022, 61 (01) : 73 - 80