Depth of interaction effect on timing resolution in PET block detectors

被引:0
作者
Ivan, A [1 ]
Burr, KC [1 ]
Shao, YP [1 ]
LeBlanc, JW [1 ]
机构
[1] Gen Elect Res, Niskayuna, NY 12309 USA
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We have investigated the effect of the depth of interaction (DOI) on the coincidence tinting distribution of a PET block detector excited with 511 keV photons. Measurements were performed with a detector consisting of a quad photomultiplier tube (PMT) optically coupled to a 6x6 array of mixed lutetium silicate (MLS) scintillator crystals with different surface treatments. The PET detector was side-illuminated with an electronically collimated beam and the coincidence tinting distribution was recorded at different DOI as the detector block was stepped through the beam. The shift of the tinting distribution peak measured the variation of the average propagation time of the scintillation photons within the block. From top to bottom (30 mm distance), the average delay ranged from 120 ps for polished crystals up to 350 ps for crystals with all sides roughened. The results of this study allowed modeling the effect of DOI delay on tinting performance for front-end irradiation with 511 keV photons, assuming a range of different values for the intrinsic tinting resolution of the detector. The relative contribution from DOI effects to the total time coincidence resolution was found to be significant only for detectors with an intrinsic time resolution less than 250 ps FWHM.
引用
收藏
页码:4156 / 4158
页数:3
相关论文
共 50 条
  • [31] Positron emission tomography (PET) detectors with depth-of- interaction (DOI) capability
    Ito M.
    Hong S.J.
    Lee J.S.
    [J]. Biomedical Engineering Letters, 2011, 1 (2) : 70 - 81
  • [32] Characterization of three layer depth of interaction PET detectors for small animal imaging
    Behnamian, H.
    Shafiee, M.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (05):
  • [33] A New Method of Depth-of-Interaction Determination for Continuous Crystal PET Detectors
    Wang, Yonggang
    Wang, Liwei
    Li, Deng
    Cheng, Xinyi
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [34] SiPM-Array Based PET Detectors with Depth-of-Interaction Correction
    Schaart, Dennis R.
    van Dam, Herman T.
    Seifert, Stefan
    Vinke, Ruud
    Dendooven, Peter
    Lohner, Herbert
    Beekman, Freek J.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2856 - +
  • [35] Development of high resolution phoswich depth-of-interaction block detectors utilizing Mg co-doped new scintillators
    Kobayashi, Takahiro
    Yamamoto, Seiichi
    Yeom, Jung-Yeol
    Kamada, Kei
    Yoshikawa, Akira
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 875 : 111 - 118
  • [36] Depth encoding multicrystal detectors for PET
    Murayama, H
    Ishibashi, H
    Uchida, H
    Omura, T
    Yamashita, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1152 - 1157
  • [37] Effect of depth of interaction resolution on the spatial resolution of SIAT aPET
    Kuang, Zhonghua
    Zhang, Ling
    Ren, Ning
    Kinyanjui, Samuel M.
    Liu, Zheng
    Sun, Tao
    Hu, Zhanli
    Yang, Yongfeng
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (22)
  • [38] Depth encoding multicrystal detectors for PET
    Natl Inst of Radiological Sciences, Chiba, Japan
    [J]. IEEE Trans Nucl Sci, 3 pt 2 (1152-1157):
  • [39] Improving PET Sensitivity and Resolution by Photon Interaction Sequence Timing Discrimination
    Ilisie, Victor
    Gimenez-Alventosa, Vicent
    Moliner, Laura
    Aguilar, Albert
    Lamprou, Efthimis
    Gonzalez, Antonio J.
    Sanchez, Filomeno
    Benlloch, Jose M.
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [40] Resolution improvement in PET using detector depth of interaction information.
    Dahlbom, M
    MacDonald, LR
    Cherry, SR
    Eriksson, L
    Casey, ME
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 162 - 162