Depth of interaction effect on timing resolution in PET block detectors

被引:0
|
作者
Ivan, A [1 ]
Burr, KC [1 ]
Shao, YP [1 ]
LeBlanc, JW [1 ]
机构
[1] Gen Elect Res, Niskayuna, NY 12309 USA
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We have investigated the effect of the depth of interaction (DOI) on the coincidence tinting distribution of a PET block detector excited with 511 keV photons. Measurements were performed with a detector consisting of a quad photomultiplier tube (PMT) optically coupled to a 6x6 array of mixed lutetium silicate (MLS) scintillator crystals with different surface treatments. The PET detector was side-illuminated with an electronically collimated beam and the coincidence tinting distribution was recorded at different DOI as the detector block was stepped through the beam. The shift of the tinting distribution peak measured the variation of the average propagation time of the scintillation photons within the block. From top to bottom (30 mm distance), the average delay ranged from 120 ps for polished crystals up to 350 ps for crystals with all sides roughened. The results of this study allowed modeling the effect of DOI delay on tinting performance for front-end irradiation with 511 keV photons, assuming a range of different values for the intrinsic tinting resolution of the detector. The relative contribution from DOI effects to the total time coincidence resolution was found to be significant only for detectors with an intrinsic time resolution less than 250 ps FWHM.
引用
收藏
页码:4156 / 4158
页数:3
相关论文
共 50 条
  • [1] Spatial resolution in PET and the effect of gamma-ray interaction depth in block detectors
    St James, S
    Thompson, C
    MEDICAL PHYSICS, 2005, 32 (07) : 2408 - 2408
  • [2] Investigation of the "block effect" on spatial resolution in PET detectors
    Tomic, N
    Thompson, CJ
    Casey, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 599 - 605
  • [3] Investigation of the "block effect" on spatial resolution in PET detectors
    Tomic, N
    Thompson, CJ
    Casey, ME
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2201 - 2205
  • [4] HIGH-RESOLUTION BLOCK DETECTORS FOR PET
    YAMASHITA, T
    WATANABE, M
    SHIMIZU, K
    UCHIDA, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 589 - 593
  • [5] Dynode-timing method for PET block detectors
    Bauer, Florian
    Zhang, Nan
    Schmand, Matthias
    Loope, Michael
    Eriksson, Lars
    Aykac, Mehmet
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (01) : 451 - 456
  • [6] Improving depth-of-interaction resolution in pixellated PET detectors using neural networks
    Zatcepin, Artem
    Pizzichemi, Marco
    Polesel, Andrea
    Paganoni, Marco
    Auffray, Etiennette
    Ziegler, Sibylle, I
    Omidvari, Negar
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17):
  • [7] Effect of depth of interaction decoding on resolution in PET: A simulation study
    Astakhov, V
    Gumplinger, P
    Moisan, C
    Ruth, TJ
    Sossi, V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1373 - 1378
  • [8] Effect of depth of interaction decoding on resolution in PET: a simulation study
    Astakhov, V
    Gumplinger, P
    Moisan, C
    Ruth, TJ
    Sossi, V
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 965 - 969
  • [9] Multi-CFD timing estimators for PET block detectors
    Ullisch, M. G.
    Moses, W. W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (01) : 55 - 59
  • [10] Dynode-timing method for PET block-detectors
    Bauer, Florian
    Zhang, Nan
    Schmand, Matthias
    Loope, Michael
    Eriksson, Lars
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3053 - 3056