Cyclic response of reinforced concrete frames partially infilled with relatively weak masonry wall

被引:7
|
作者
Baniahmadi, Mahmoud [1 ]
Vafaei, Mohammadreza [1 ]
Alih, Sophia C. [2 ]
机构
[1] Univ Teknol Malaysia, Fac Engn, Sch Civil Engn, Skudai, Johor, Malaysia
[2] Univ Teknol Malaysia, Inst Noise & Vibrat, Fac Engn, Sch Civil Engn, Skudai, Johor, Malaysia
来源
JOURNAL OF BUILDING ENGINEERING | 2022年 / 46卷
关键词
Cyclic response; Infill wall; RC frame; Weak masonry; Partially infilled; OF-PLANE INTERACTION; SEISMIC PERFORMANCE; RC FRAME; BEHAVIOR; EARTHQUAKE; BUILDINGS; COLUMN; STRENGTH; RETROFIT; DESIGN;
D O I
10.1016/j.jobe.2021.103722
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Partially infilled reinforced concrete (RC) frames have experienced significant damage during past earthquakes. Due to the partial confinement of columns in these structures, the shear force demand increases significantly, resulting in a brittle failure. This study investigated the efficiency of the strong frame-weak infill wall design concept to avoid the brittle failure mode of captive columns. For this purpose, two large-scale partially infilled RC frames with similar material properties and geometry but with different seismic detailing were constructed and subjected to a quasi-static cyclic loading. The obtained results from the conducted experiment were compared with two bare frames with similar detailing and geometry. It was observed that the partially infilled frames had up to 49.6% larger ultimate load than bare frames. Besides, at a 3% drift ratio, the cumulative energy dissipation of partially infilled frames was up to 180% more than bare frames. However, the stiffness degradation rate of the partially infilled frames was higher than the bare frames, particularly at drift ratios less than 1%. Besides, at larger drift ratios (i.e., around 3%), the infill walls contributed to partially infilled frames' lateral strength and increased it up to 60% compared with the bare frames.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Seismic response of reinforced concrete frames infilled with weakly reinforced masonry panels
    Calvi, GM
    Bolognini, D
    JOURNAL OF EARTHQUAKE ENGINEERING, 2001, 5 (02) : 153 - 185
  • [2] Influence of masonry panels with openings on the seismic response of reinforced concrete infilled frames
    Noui, S.
    Kadid, A.
    Bali, A.
    SCIENTIA IRANICA, 2019, 26 (01) : 157 - 166
  • [3] A proposal for the numerical modelling of monotonic and cyclic behaviour of masonry infilled reinforced concrete frames
    Bagnoli, Matteo
    Grande, Ernesto
    Milani, Gabriele
    INTERNATIONAL JOURNAL OF MASONRY RESEARCH AND INNOVATION, 2024, 9 (03) : 268 - 298
  • [4] An experimental study on reinforced concrete partially infilled frames
    Anil, Ozgur
    Altin, Sinan
    ENGINEERING STRUCTURES, 2007, 29 (03) : 449 - 460
  • [5] Behavior of masonry-infilled nonductile reinforced concrete frames
    Al-Chaar, Ghassan
    Issa, Mohsen
    Sweeney, Steve
    Journal of Structural Engineering, 2002, 128 (08) : 1055 - 1063
  • [6] Assessment of masonry infilled reinforced-concrete frames with openings
    Proračun armirano-betonskih okvira ispunjenih zidem s otvorima
    1600, Strojarski Facultet (20):
  • [7] Masonry infilled reinforced concrete frames under horizontal loading
    Butenweg, Christoph
    Marinkovic, Marko
    Kubalski, Thomas
    MAUERWERK, 2016, 20 (04) : 305 - 312
  • [8] ASSESSMENT OF MASONRY INFILLED REINFORCED-CONCRETE FRAMES WITH OPENINGS
    Sigmund, Vladimir
    Penava, Davorin
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2013, 20 (03): : 459 - 466
  • [9] Behavior of masonry-infilled nonductile reinforced concrete frames
    Al-Chaar, G
    Issa, M
    Sweeney, S
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (08): : 1055 - 1063
  • [10] Lateral stiffness of partially infilled reinforced concrete (RC) frames
    Singha, Birendra Nath
    Mondal, Goutam
    STRUCTURES, 2024, 70