Electro-characteristics of Myocardial Pouches and Reduction of the Frequency of Steam Pops During Radiofrequency Ablation

被引:2
作者
Luo, Jianfeng [1 ]
Guo, Fei [1 ]
Zhu, Hongjun [1 ]
Su, Hao [1 ]
Wu, Yuanbo [2 ]
Zhu, Jing [1 ]
Zhang, Can [1 ]
Xu, Jian [1 ]
机构
[1] Univ Sci & Technol China, Div Life Sci & Med, Affiliated Hosp USTC 1, Dept Cardiol, Hefei, Peoples R China
[2] Univ Sci & Technol China, Div Life Sci & Med, Affiliated Hosp USTC 1, Dept Neurol, Hefei, Peoples R China
关键词
arrhythmia; atrial fibrillation; radiofrequency ablation; impedance; pouch; steam pop; CATHETER ABLATION; LESION SIZE; IMPEDANCE; ISTHMUS;
D O I
10.3389/fphys.2022.816865
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background: Radiofrequency ablation (RFA) effectively treats arrhythmia. Steam pop (SP) is a dangerous complication of RFA, which can lead to pericardial tamponade or even death.Objective: This study aimed to explore the electro-characteristics of myocardial pouches, and the relationship between SP, pouch, and impedance.Methods: Swine myocardium was divided into the pouch group and smooth myocardium group. Continuous RFA at 50 W was applied. The initial impedance reduction within the first 3 s of ablation and the time from the start of ablation to SP were recorded. After enabling the delta impedance cutoff function, RFA was performed at different percentage of delta impedance (PDI) cutoff thresholds.Results: The impedance was higher for the pouch myocardium compared to the smooth myocardium (123.22 +/- 8.63 omega and 95.75 +/- 4.75 omega, respectively; p < 0.001). The RFA duration before SPs was shorter in the pouch group compared to the smooth myocardium group [9 s (interquartile range, IQR: 6.25-13 s) and 33 s (IQR: 26.25-40.75 s), respectively; p < 0.001]. Within the first 3 s of RFA, impedance reduction (24.65 +/- 6.57 omega and 12.78 +/- 3.35 omega, respectively; p < 0.001) and PDI [19.18% (IQR: 16.39-24.20%) and 12.96% (IQR: 11.17-14.39%), respectively; p < 0.001] were greater in the pouch group compared to the smooth myocardium group. A PDI of 15% and delta time of 3 s effectively reduced the frequency of SPs without seriously affecting RFA use.Conclusion: SPs occur more frequently in the pouch area during RFA. Appropriate delta impedance cutoff settings (PDI: 15%; delta time: 3 s) can reduce the frequency of SPs and improve the RFA safety.
引用
收藏
页数:8
相关论文
共 20 条
  • [1] Usefulness of Pre-Procedure Cavotricuspid Isthmus Imaging by Modified Transthoracic Echocardiography for Predicting Outcome of Isthmus-Dependent Atrial Flutter Ablation
    Chen, Jan-Yow
    Lin, Kuo-Hung
    Liou, Ying-Ming
    Chang, Kuan-Cheng
    Huang, Shoei K. Stephen
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (10) : 1148 - 1155
  • [2] Detection of inadvertent catheter movement into a pulmonary vein during radiofrequency catheter ablation by real-time impedance monitoring
    Cheung, P
    Hall, B
    Chugh, A
    Good, E
    Lemola, K
    Han, J
    Tamirisa, K
    Pelosi, F
    Morady, F
    Oral, H
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (06) : 674 - 678
  • [3] Ablation with an internally irrigated radiofrequency catheter: Learning how to avoid steam pops
    Cooper, JM
    Sapp, JL
    Tedrow, U
    Pellegrini, CP
    Robinson, D
    Epstein, LM
    Stevenson, WG
    [J]. HEART RHYTHM, 2004, 1 (03) : 329 - 333
  • [4] Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus
    Da Costa, A
    Faure, E
    Thévenin, J
    Messier, M
    Bernard, S
    Abdel, K
    Robin, C
    Romeyer, C
    Isaaz, K
    [J]. CIRCULATION, 2004, 110 (09) : 1030 - 1035
  • [5] Left Atrial Hypertension, Electrical Conduction Slowing, and Mechanical Dysfunction - The Pathophysiological Triad in Atrial Fibrillation-Associated Atrial Cardiomyopathy
    Eichenlaub, Martin
    Mueller-Edenborn, Bjoern
    Minners, Jan
    Jander, Nikolaus
    Allgeier, Martin
    Lehrmann, Heiko
    Schoechlin, Simon
    Allgeier, Juergen
    Trenk, Dietmar
    Neumann, Franz-Josef
    Arentz, Thomas
    Jadidi, Amir
    [J]. FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [6] Pulmonary vein stenosis or occlusion after catheter ablation of atrial fibrillation: long-term comparison of drug-eluting versus large bare metal stents
    Fink, Thomas
    Schlueter, Michael
    Heeger, Christian-Hendrik
    Lemes, Christine
    Lin, Tina
    Maurer, Taman
    Metzner, Andreas
    Mathew, Shibu
    Reissmann, Bruno
    Wohlmuth, Peter
    Rillig, Andreas
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Tilz, Roland Richard
    [J]. EUROPACE, 2018, 20 (10): : E148 - E155
  • [7] 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)
    Hindricks, Gerhard
    Potpara, Tatjana
    Dagres, Nikolaos
    Arbelo, Elena
    Bax, Jeroen J.
    Blomstroem-Lundqvist, Carina
    Boriani, Giuseppe
    Castella, Manuel
    Dan, Gheorghe-Andrei
    Dilaveris, Polychronis E.
    Fauchier, Laurent
    Filippatos, Gerasimos
    Kalman, Jonathan M.
    La Meir, Mark
    Lane, Deirdre A.
    Lebeau, Jean-Pierre
    Lettino, Maddalena
    Lip, Gregory Y. H.
    Pinto, Fausto J.
    Thomas, G. Neil
    Valgimigli, Marco
    Van Gelder, Isabelle C.
    Van Putte, Bart P.
    Watkins, Caroline L.
    [J]. EUROPEAN HEART JOURNAL, 2021, 42 (05) : 373 - 498
  • [8] Relationship Between Catheter Contact Force and Radiofrequency Lesion Size and Incidence of Steam Pop in the Beating Canine Heart Electrogram Amplitude, Impedance, and Electrode Temperature Are Poor Predictors of Electrode-Tissue Contact Force and Lesion Size
    Ikeda, Atsushi
    Nakagawa, Hiroshi
    Lambert, Hendrik
    Shah, Dipen C.
    Fonck, Edouard
    Yulzari, Aude
    Sharma, Tushar
    Pitha, Jan V.
    Lazzara, Ralph
    Jackman, Warren M.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (06) : 1174 - 1180
  • [9] Visualizing induced silent steam pop with intracardiac echocardiography
    Kondo, Yusuke
    Ueda, Marehiko
    Kobayashi, Yoshio
    [J]. EUROPACE, 2017, 19 (07): : 1145 - 1145
  • [10] Lesion Index Titration Using Contact-Force Technology Enables Safe and Effective Radiofrequency Lesion Creation at the Root of the Aorta and Pulmonary Artery
    Manuel Alfonso-Almazan, Jose
    Quintanilla, Jorge G.
    Jesus Garcia-Torrent, Maria
    Laguna-Castro, Santiago
    Rodriguez-Bobada, Cruz
    Gonzalez, Pablo
    Jose Gonzalez-Ferrer, Juan
    Salinas, Pablo
    Canadas-Godoy, Victoria
    Moreno, Javier
    Borrego-Bernabe, Luis
    Perez-Castellano, Nicasio
    Jalife, Jose
    Perez-Villacastin, Julian
    Filgueiras-Rama, David
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (03)