Evaluation of an elliptical grid mirror electrostatic analyzer for space applications

被引:1
|
作者
Chornay, DJ
Hunsaker, FH
Keller, JW
机构
[1] Lab. for Extraterrestrial Physics, Goddard Space Flight Center, Greenbelt
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1997年 / 68卷 / 03期
关键词
D O I
10.1063/1.1147933
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on our investigation into the development of electrostatic mirror based charged particle analyzers for space plasma physics experimentation. For this work, we tested an elliptical mirror analyzer which was designed to provide a wide, 2-dimensional field of view with high throughput and good angular resolution. Measurements with an ion beam demonstrated 2 degrees full width at half-maximum angular resolution over a 16x16 degrees field of view (FOV) and 4 degrees resolution over a 40x40 degrees FOV for an optical system with a linear dimension (entrance aperture to the particle detector) of 20 cm. The energy resolution is variable, similar in operation to a retarding-potential-analyzer or a modulated grid Faraday cup, with a geometric factor of 3.2x10(-3) cm(2) str Delta E/E for an energy resolution setting of 10%. (C) 1997 American Institute of Physics.
引用
收藏
页码:1604 / 1608
页数:5
相关论文
共 50 条
  • [21] Applications of MEMS in Segmented Mirror Space Telescopes
    Agrawal, Brij
    Kubby, Joel
    MEMS ADAPTIVE OPTICS V, 2011, 7931
  • [22] DEMONSTRATION OF A PHASED SEGMENTED MIRROR FOR SPACE APPLICATIONS
    JONES, PA
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1981, 71 (12) : 1567 - 1567
  • [23] Miniature ion analyzer for applications in space weather monitoring
    Shestakov, A. Yu
    Moiseenko, D. A.
    Shuvalov, S. D.
    Zhuravlev, R. N.
    ENGINEERING RESEARCH EXPRESS, 2022, 4 (02):
  • [24] ELECTROSTATIC TOROIDAL ANALYZER FOR STUDY OF CHARGED-PARTICLE FLUXES IN COSMIC SPACE
    VOLKOV, GI
    ZASTENKE.GN
    KOPYLOV, VF
    POZDNOV, YN
    REMIZOV, AP
    KHOKHLOV, MZ
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (01): : 43 - 45
  • [25] AN ELECTROSTATIC ANALYZER WITH NO FRINGE FIELD FOR MEASUREMENTS OF LOW ENERGY PARTICLES ON SPACE VEHICLES
    MARIANI, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1970, 41 (06): : 807 - &
  • [26] Retarding potential analyzer: Principles, designs, and space applications
    Lai, Shu T.
    Miller, Catherine
    AIP ADVANCES, 2020, 10 (09)
  • [27] QUADRATIC PULSE-HEIGHT ANALYZER FOR SPACE APPLICATIONS
    BURTIS, DW
    AALAMI, D
    EVELYNVE.RH
    SARKADY, AA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (01) : 613 - &
  • [28] USAFA Integrated Miniaturized Electrostatic Analyzer (iMESA)-An Undergraduate Space Weather Constellation
    McHarg, Geoff
    Neal, Parris
    Taormina, Nikolas
    Strom, Alex
    Balthazor, Richard
    SPACE WEATHER-THE INTERNATIONAL JOURNAL OF RESEARCH AND APPLICATIONS, 2015, 13 (12): : 827 - 830
  • [29] TRANSMISSION PROPERTIES OF A CYLINDRICAL MIRROR ANALYZER VIEWED IN ENERGY-ANGLE SPACE
    EAGEN, CF
    SICKAFUS, EN
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (10): : 1269 - 1277
  • [30] Statistical performance evaluation of electrostatic micro actuators for a deformable mirror
    Krishnamoorthy, R
    Bifano, T
    Sandri, G
    MICROELECTRONIC STRUCTURES AND MEMS FOR OPTICAL PROCESSING II, 1996, 2881 : 35 - 44