A method for improving the accuracy of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) using determined plasma temperature by genetic algorithm (GA)

被引:42
|
作者
Dong, Juan [1 ]
Liang, Long [1 ]
Wei, Jiao [1 ]
Tang, Hongsheng [1 ]
Zhang, Tianlong [1 ]
Yang, Xiaofeng [1 ]
Wang, Kang [2 ]
Li, Hua [1 ]
机构
[1] NW Univ Xian, Coll Chem & Mat Sci, Inst Analyt Sci, Xian 710069, Peoples R China
[2] Changan Univ, Coll Sci, Xian 710064, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
LOCAL THERMODYNAMIC-EQUILIBRIUM; SELF-ABSORPTION; ELEMENTAL ANALYSIS; EMISSION-LINES; SPECTRAL-LINES; CLASSIFICATION; SELECTION;
D O I
10.1039/c4ja00470a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accuracy is still a challenge for classical calibration-free laser-induced breakdown spectroscopic (CF-LIBS) quantitative analysis since absolute theoretical calculation and mathematical models cannot compensate for the self-absorption effect and plasma temperature variability. The aim of this research is to obtain a more accurate plasma temperature which contributes to the precise determination of the elemental composition of unknown samples for CF-LIBS. Herein, an internal reference-external standard with iteration correction (IRESIC) method is proposed to correct for the self-absorption effect and plasma temperature in CF-LIBS based on an internal reference line and one standard sample. The spectral intensities of each species are corrected by an internal reference line via the iteration procedure, and the internal reference line suffers from a negligible self-absorption effect for self-absorption correction. Furthermore, one standard sample matrix-matched with the unknown samples along with the genetic algorithm (GA) is utilized to simulate the accurate plasma temperature of the unknown samples. It is worth mentioning that the GA is used for plasma temperature correction through iteration correction for the first time in CF-LIBS. The proposed method demonstrates a significant improvement in accuracy compared with the classical CF-LIBS in the quantitative analysis of aluminum-bronze alloy samples due to the integrated merits of internal reference line usage and accurate plasma temperature evaluation.
引用
收藏
页码:1336 / 1344
页数:9
相关论文
共 50 条
  • [41] Correction of self-absorption effect in calibration-free laser-induced breakdown spectroscopy by an internal reference method
    Sun, Lanxiang
    Yu, Haibin
    TALANTA, 2009, 79 (02) : 388 - 395
  • [42] A single-beam-splitting technique combined with a calibration-free method for field-deployable applications using laser-induced breakdown spectroscopy
    Xu, Mingjun
    Lin, Qingyu
    Yang, Guang
    Xu, Tao
    Zhang, Tianlong
    Wang, Xu
    Wang, Shuai
    Bian, Fang
    Duan, Yixiang
    RSC ADVANCES, 2015, 5 (06): : 4537 - 4546
  • [43] Quantitative analysis of Ge/Si alloys using double-pulse calibration-free laser-induced breakdown spectroscopy
    Shakeel, Hira
    Haq, S. U.
    Abbas, Qamar
    Nadeem, Ali
    Palleschi, V.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 146 : 101 - 105
  • [44] Double-pulse and calibration-free laser-induced breakdown spectroscopy at low-ablative energies
    Contreras, V.
    Meneses-Nava, M. A.
    Barbosa-Garcia, O.
    Maldonado, J. L.
    Ramos-Ortiz, G.
    OPTICS LETTERS, 2012, 37 (22) : 4591 - 4593
  • [45] Quantification of impurities in diatomite via sensitivity-improved calibration-free laser-induced breakdown spectroscopy
    Belkhir, Nabila
    Beldjilali, Sid Ahmed
    Benelmouaz, Mohamed Amine
    Hamzaoui, Saad
    Alloncle, Anne-Patricia
    Gerhard, Christoph
    Hermann, Joerg
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (10) : 2551 - 2564
  • [46] Analysis of Multi-elemental Thin Films via Calibration-Free Laser-Induced Breakdown Spectroscopy
    Hermann, Jorg
    Axente, Emanuel
    Pelascini, Frederic
    Craciun, Valentin
    ANALYTICAL CHEMISTRY, 2019, 91 (03) : 2544 - 2550
  • [47] Deuterium detection and quantification by laser-induced breakdown spectroscopy and calibration-free analysis in ITER relevant samples
    Almaviva, Salvatore
    Caneve, Luisa
    Colao, Francesco
    Maddaluno, Giorgio
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 2087 - 2091
  • [48] Analysis of an Al-Sn-Cu alloy by calibration-free laser-induced breakdown spectroscopy under varying sample temperature conditions
    Hai, Ran
    Wang, Xueyan
    Bai, Xue
    He, Zhonglin
    Wu, Ding
    Li, Cong
    Ding, Hongbin
    Yao, Xuefeng
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2024, 217
  • [49] Self-absorption effect in calibration-free laser-induced breakdown spectroscopy: Analysis of mineral profile in Maerua oblongifolia plant
    Qasim, M.
    Anwar-ul-Haq, M.
    Shah, Amin
    Afgan, M. Sher
    Haq, S. U.
    Khan, Rameez Abbas
    Baig, M. Aslam
    MICROCHEMICAL JOURNAL, 2022, 175
  • [50] Comparative investigation of laser ablation plumes in air and argon by analysis of spectral line shapes: Insights on calibration-free laser-induced breakdown spectroscopy
    Hermann, Joerg
    Gerhard, Christoph
    Axente, Emanuel
    Dutouquet, Christophe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 100 : 189 - 196