A method for improving the accuracy of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) using determined plasma temperature by genetic algorithm (GA)

被引:42
|
作者
Dong, Juan [1 ]
Liang, Long [1 ]
Wei, Jiao [1 ]
Tang, Hongsheng [1 ]
Zhang, Tianlong [1 ]
Yang, Xiaofeng [1 ]
Wang, Kang [2 ]
Li, Hua [1 ]
机构
[1] NW Univ Xian, Coll Chem & Mat Sci, Inst Analyt Sci, Xian 710069, Peoples R China
[2] Changan Univ, Coll Sci, Xian 710064, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
LOCAL THERMODYNAMIC-EQUILIBRIUM; SELF-ABSORPTION; ELEMENTAL ANALYSIS; EMISSION-LINES; SPECTRAL-LINES; CLASSIFICATION; SELECTION;
D O I
10.1039/c4ja00470a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accuracy is still a challenge for classical calibration-free laser-induced breakdown spectroscopic (CF-LIBS) quantitative analysis since absolute theoretical calculation and mathematical models cannot compensate for the self-absorption effect and plasma temperature variability. The aim of this research is to obtain a more accurate plasma temperature which contributes to the precise determination of the elemental composition of unknown samples for CF-LIBS. Herein, an internal reference-external standard with iteration correction (IRESIC) method is proposed to correct for the self-absorption effect and plasma temperature in CF-LIBS based on an internal reference line and one standard sample. The spectral intensities of each species are corrected by an internal reference line via the iteration procedure, and the internal reference line suffers from a negligible self-absorption effect for self-absorption correction. Furthermore, one standard sample matrix-matched with the unknown samples along with the genetic algorithm (GA) is utilized to simulate the accurate plasma temperature of the unknown samples. It is worth mentioning that the GA is used for plasma temperature correction through iteration correction for the first time in CF-LIBS. The proposed method demonstrates a significant improvement in accuracy compared with the classical CF-LIBS in the quantitative analysis of aluminum-bronze alloy samples due to the integrated merits of internal reference line usage and accurate plasma temperature evaluation.
引用
收藏
页码:1336 / 1344
页数:9
相关论文
共 50 条
  • [31] A calibration-free model for laser-induced breakdown spectroscopy using non-gated detectors
    Hou, Zongyu
    Gu, Weilun
    Li, Tianqi
    Wang, Zhe
    Li, Liang
    Yu, Xiang
    Zhang, Yecai
    Liu, Zijun
    FRONTIERS OF PHYSICS, 2022, 17 (06)
  • [32] Advancing environmental monitoring: unveiling heavy metals contamination with calibration-free picosecond laser-induced breakdown spectroscopy (CF-PS-LIBS)
    Fayek, Noura
    Tawfik, Walid
    Khalafallah, Ahmed
    Fikry, Mohamed
    JOURNAL OF OPTICS-INDIA, 2025,
  • [33] Quantitative elemental analysis of steel using calibration-free laser-induced breakdown spectroscopy
    Shah, M. L.
    Pulhani, A. K.
    Gupta, G. P.
    Suri, B. M.
    APPLIED OPTICS, 2012, 51 (20) : 4612 - 4621
  • [34] Elemental analysis of cemented carbides by calibration-free portable laser-induced breakdown spectroscopy
    Wang, Shuai
    Tian, Di
    Xu, Mingjun
    Lin, Qingyu
    Wang, Jie
    Guo, Guangmeng
    Yang, Guang
    Duan, Yixiang
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2018, 46 (03) : 277 - 291
  • [35] Calibration-Free Quantitative Analysis of Lithium-Ion Battery (LiB) Electrode Materials Using Laser-Induced Breakdown Spectroscopy (LIBS)
    Pamu, Ravi
    Davari, Seyyed Ali
    Darbar, Devendrasinh
    Self, Ethan C.
    Nanda, Jagjit
    Mukherjee, Dibyendu
    ACS APPLIED ENERGY MATERIALS, 2021, 4 (07) : 7259 - 7267
  • [36] Measurement error due to self-absorption in calibration-free laser-induced breakdown spectroscopy
    Taleb, Aya
    Motto-Ros, Vincent
    Carru, Mauro J.
    Axente, Emanuel
    Craciun, Valentin
    Pelascini, Frederic
    Hermann, Jorg
    ANALYTICA CHIMICA ACTA, 2021, 1185
  • [37] Analysis of Soil by Magnetic Field Assisted Calibration-Free Laser Induced Breakdown Spectroscopy (CF-LIBS) and Laser Ablation - Time-of-Flight Mass Spectrometry (LA-TOF-MS)
    Akhtar, Mahmood
    Jabbar, Abdul
    Mahmood, Shaukat
    Umar, Zeshan Adeel
    Ahmed, Rizwan
    Baig, Muhammad Aslam
    ANALYTICAL LETTERS, 2019, 52 (14) : 2312 - 2328
  • [38] Error analysis in optimization problems relevant for calibration-free laser-induced breakdown spectroscopy
    Maali, J. J.
    Shabanov, S. V.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2019, 222 : 236 - 246
  • [39] Optimization of temporal window for application of calibration free-laser induced breakdown spectroscopy (CF-LIBS) on copper alloys in air employing a single line
    Mal, Eshita
    Junjuri, Rajendhar
    Gundawar, Manoj Kumar
    Khare, Alika
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (02) : 319 - 330
  • [40] Calibration-free analysis of immersed metal alloys using long-pulse-duration laser-induced breakdown spectroscopy
    Jabbar, Abdul
    Hou, Zongyu
    Liu, Jiacen
    Ahmed, Rizwan
    Mahmood, Shaukat
    Wang, Zhe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 157 : 84 - 90