Effect of different parameters of Er:YAG laser irradiations on class V composite restorations: A scanning electron microscopy study

被引:5
作者
Ozel, Emre [1 ]
Tuna, Elif Bahar [2 ]
Firatli, Sonmez [3 ]
Firatli, Erhan [4 ]
机构
[1] Kocaeli Univ, Dept Restorat Dent, Fac Dent, TR-41190 Basiskele, Kocaeli, Turkey
[2] Istanbul Univ, Dept Pediat Dent, Fac Dent, Istanbul, Turkey
[3] Istanbul Univ, Dept Orthodont, Fac Dent, Istanbul, Turkey
[4] Istanbul Univ, Dept Periodontol, Fac Dent, Istanbul, Turkey
关键词
Class V cavity; different parameters; Er:YAG laser; microleakage; nanohybrid composite; ER-YAG LASER; STEP POLISHING SYSTEMS; ALUMINUM-GARNET LASER; CAVITY PREPARATION; SURFACE-ROUGHNESS; DIAMOND BUR; MICROLEAKAGE; DENTISTRY;
D O I
10.1002/sca.21292
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The purpose of this study was to compare different parameters of Er:YAG laser irradiations on the marginal microleakage of Class V resin composite restorations. A total of 45 extracted premolars were selected for the study. Class V cavities prepared on both buccal and lingual surfaces of teeth by Er:YAG laser or bur and divided into nine groups. The occlusal margins were in enamel and the cervical margins were in cementum. Group-1: bur preparation; Group-2: laser preparation (lp) (600mJ/5Hz); Group-3: lp (300mJ/10Hz); Group-4: lp (200mJ/15Hz); Group-5: lp (150mJ/20Hz); Group-6: lp (200mJ/20Hz); Group-7: lp (300mJ/14Hz); Group-8: lp (400mJ/10Hz); Group-9: lp (700mJ/5Hz). All teeth were stored in distilled water at 37 degrees C for 24h, then thermocycled 1,000 times (5-55 degrees C). Five teeth from each group were chosen for the microleakage investigation and two teeth for the scanning electron microscope (SEM) evaluation. Teeth, which were prepared for the microleakage test were immersed in 0.5% methylene blue dye for 24h. After immersing, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed by Kruskal-Wallis and Mann-Whitney U tests (p<0.05). More microleakage was observed in cervical regions compared to occlusal regions in all groups (p<0.05) except for Group 6 (p>0.05). No significant difference was observed among groups in terms of occlusal and cervical surfaces, separately (p>0.05). It may be concluded that the cavities prepared by Er:YAG laser showed higher degree of microleakage than bur prepared at cervical regions. Different parameters of Er:YAG laser irradiations affected microleakage. SCANNING 38:434-441, 2016. (c) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:434 / 441
页数:8
相关论文
共 50 条
[21]   Marginal Leakage of Class V Composite Restorations Assessed Using Microcomputed Tomography and Scanning Electron Microscope [J].
Rengo, C. ;
Goracci, C. ;
Ametrano, G. ;
Chieffi, N. ;
Spagnuolo, G. ;
Rengo, S. ;
Ferrari, M. .
OPERATIVE DENTISTRY, 2015, 40 (04) :440-448
[22]   Effects of different types of adhesive systems on the microleakage of compomer restorations in Class V cavities prepared by Er,Cr:YSGG laser in primary teeth [J].
Baygin, Ozgul ;
Korkmaz, Fatih Mehmet ;
Arslan, Ipek .
DENTAL MATERIALS JOURNAL, 2012, 31 (02) :206-214
[23]   Microleakage in class V cavities prepared using conventional method versus Er:YAG laser restored with glass ionomer cement or resin composite [J].
Peker, Sertac ;
Giray, Figen Eren ;
Durmus, Basak ;
Bekiroglu, Nural ;
Kargul, Betul ;
Ozcan, Mutlu .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2017, 31 (05) :509-519
[24]   Evaluation of Blood Cell Attachment on Er:Yag Laser Applied Root Surface Using Scanning Electron Microscopy [J].
Cekici, Ali ;
Maden, Ilay ;
Yildiz, Sercan ;
San, Tangul ;
Isik, Gulden .
INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2013, 10 (05) :560-566
[25]   Evaluation of the microleakage of different class V cavities prepared by using Er:YAG laser, ultrasonic device, and conventional rotary instruments with two dentin bonding systems (an in vitro study) [J].
Gullshang Muhammed ;
Raad Dayem .
Lasers in Medical Science, 2015, 30 :969-975
[26]   Evaluation of the microleakage of different class V cavities prepared by using Er:YAG laser, ultrasonic device, and conventional rotary instruments with two dentin bonding systems (an in vitro study) [J].
Muhammed, Gullshang ;
Dayem, Raad .
LASERS IN MEDICAL SCIENCE, 2015, 30 (03) :969-975
[27]   Comparative study in vitro of microleakage in class V cavity preparation with and without Er:YAG laser [J].
Lizarelli, RD ;
Kurachi, C ;
Neto, STP ;
Bagnato, VS .
LASERS IN DENTISTRY VI, 2000, 1 :254-260
[28]   The effect of different energy levels of the Er: YAG laser on the repair bond strength of a nanohybrid composite resin [J].
Celiksoz, Ozge ;
Recen, Duygu ;
Peskersoy, Cem .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2023, 237 (01) :124-133
[29]   Comparison of Microleakage of Three Adhesive Systems in Class V Composite Restorations Prepared with Er,Cr:YSGG Laser [J].
Kimyai, Soodabeh ;
Ajami, Amir Ahmad ;
Chaharom, Mohammad Esmaeel Ebrahimi ;
Oskoee, Jafar Sadjadi .
PHOTOMEDICINE AND LASER SURGERY, 2010, 28 (04) :505-510
[30]   Root planing with Er:YAG laser X Gracey currette:: a study in vitro in scanning electron microscopic. [J].
Mello, FAS ;
Mello, AMD ;
Matson, E ;
Mattos, AB ;
Mello, GS .
LASERS IN DENTISTRY VII, 2001, 4249 :22-27