How do angioplasty balloons work: a computational study on balloon expansion forces

被引:13
作者
Capelli, Claudio [1 ]
Nordmeyer, Johannes [1 ]
Schievano, Silvia [1 ,2 ]
Lurz, Philipp [1 ]
Khambadkone, Sachin [1 ,2 ]
Lattanzio, Simone [3 ]
Taylor, Andrew M. [1 ,2 ]
Petrini, Lorenzo [4 ]
Migliavacca, Francesco [4 ]
Bonhoeffer, Philipp [1 ]
机构
[1] UCL Inst Child Hlth, Cardiovasc Unit, London WC1N 1EH, England
[2] Great Ormond St Hosp Sick Children, Cardioresp Unit, London WC1N 3JH, England
[3] Univ Insubria, Dept Biomed Expt & Clin Sci, Varese, Italy
[4] Politecn Milan, Dept Struct Engn, I-20133 Milan, Italy
关键词
Paediatric interventions; balloon angioplasty; catheterisation; computational modelling; CORONARY ANGIOPLASTY;
D O I
10.4244/EIJV6I5A106
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To investigate the impact of balloon inflation pressure and balloon diameter on the expansion forces exerted in a stenosed vessel (congenital heart disease applications) using computational models. Methods and results: A simplified three-dimensional model of a vessel with a cylindrical stenosis was created. Two low-compliance balloons with different inflation diameters (10 vs. 16 mm) were modelled. Finite element simulations of balloon expansions were performed. To dilate the stenosis from 4 to 10 mm lumen diameter, the large balloon needed less inflation pressure than the small balloon (0.55 vs. 1.00 MPa). Under these circumstances, the large balloon also achieved higher stresses at the stenotic vessel site (5.23 +/- 0.10 vs. 3.97 +/- 0.04 MPa, p<0.001). When using inflation pressures that led to equal surface stresses of both balloons, the large balloon could exert higher expansion forces onto the stenotic site, achieving higher stresses (5.18 +/- 0.09 vs. 3.38 +/- 0.01 MPa, p<0.001) and greater lumen diameter (9.73 vs. 8.68 mm). Conclusions: In a computerised model of balloon dilatation, balloon diameter had a greater impact on the expansion force than inflation pressure. This finding emphasises the importance of choosing an appropriate balloon diameter to achieve optimal haemodynamic outcomes.
引用
收藏
页码:638 / 642
页数:5
相关论文
共 9 条
[1]   Realistic finite element-based stent design: The impact of balloon folding [J].
De Beule, Matthieu ;
Mortier, Peter ;
Carlier, Stphane G. ;
Verhegghe, Benedict ;
Van Impe, Rudy ;
Verdonck, Pascal .
JOURNAL OF BIOMECHANICS, 2008, 41 (02) :383-389
[2]   Functional properties and performance of new and reprocessed coronary angioplasty balloon catheters [J].
Fedel, Mariangela ;
Tessarolo, Francesco ;
Ferrari, Paolo ;
Loesche, Christian ;
Ghassemieh, Nikou ;
Guarrera, Giovanni Maria ;
Nollo, Giandomenico .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (02) :364-372
[3]   2 HUGGING BALLOONS AT HIGH-PRESSURES SUCCESSFULLY DILATE A LESION REFRACTORY TO ROUTINE CORONARY ANGIOPLASTY [J].
FELD, H ;
VALERIO, L ;
SHANI, J .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 24 (02) :105-107
[4]   Finite element modeling of balloon angioplasty by considering overstretch of remnant non-diseased tissues in lesions [J].
Gasser, T. Christian ;
Holzapfel, Gerhard A. .
COMPUTATIONAL MECHANICS, 2007, 40 (01) :47-60
[5]   Biomechanical behavior of the arterial wall and its numerical characterization [J].
Holzapfel, GA ;
Weizsacker, HW .
COMPUTERS IN BIOLOGY AND MEDICINE, 1998, 28 (04) :377-392
[6]   PERCUTANEOUS BALLOON VALVOTOMY OF CONGENITAL PULMONARY STENOSIS USING OVERSIZED BALLOONS [J].
RADTKE, W ;
KEANE, JF ;
FELLOWS, KE ;
LANG, P ;
LOCK, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (04) :909-915
[7]   Three-dimensional finite element analysis of residual stress in arteries [J].
Raghavan, ML ;
Trivedi, S ;
Nagaraj, A ;
McPherson, DD ;
Chandran, KB .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (02) :257-263
[8]   EARLY RESULTS AND FOLLOW-UP OF BALLOON ANGIOPLASTY FOR BRANCH PULMONARY-ARTERY STENOSES [J].
ROTHMAN, A ;
PERRY, SB ;
KEANE, JF ;
LOCK, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) :1109-1117
[9]   INFLUENCE OF BALLOON SIZE ON INITIAL SUCCESS, ACUTE COMPLICATIONS, AND RESTENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - A PROSPECTIVE RANDOMIZED STUDY [J].
ROUBIN, GS ;
DOUGLAS, JS ;
KING, SB ;
LIN, S ;
HUTCHISON, N ;
THOMAS, RG ;
GRUENTZIG, AR .
CIRCULATION, 1988, 78 (03) :557-565