Moment connections to circular concrete-filled steel tube columns

被引:60
|
作者
Azizinamini, A [1 ]
Schneider, SP
机构
[1] Univ Nebraska, Dept Civil Engn, Lincoln, NE 68588 USA
[2] Kramer Gehlen & Assoc, Vancouver, WA 98660 USA
关键词
composite columns; beams; connections; cyclic tests; full-scale tests;
D O I
10.1061/(ASCE)0733-9445(2004)130:2(213)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As part of the U.S.-Japan Cooperative Research Program on Composite/Hybrid Structures (1992), investigations were carried out at the University of Nebraska-Lincoln and University of Illinois, to develop moment connection details and accompanying design provisions for connecting steel beams to circular concrete filled tube (CFT) columns. This paper provides an overview of the work carried out. Work at the University of Illinois consisted of evaluating the inelastic response of six possible connection details. Six large-scale connections were tested to failure using the quasi-static test method. Connections welded to the skin of the tube created large distortions of the tube wall, and were susceptible to weld, flange, or tube wall fracture. External diaphragm and continuous web details exhibited more favorable inelastic behavior, but the flexural strength of these connections began to deteriorate relatively early in the imposed deformation history. Continuing the flanges through the composite column showed adequate strength, however due to excessive slipping this connection did not dissipate significant inelastic dynamic energy. One of the details tested at the University of Illinois was passing the girder section through the CFT columns. This through beam detail provided the most effective detail to achieve the ideal rigid connection condition. Work at the University of Nebraska-Lincoln concentrated on comprehending the behavior of the through beam connection detail. The behavior of CFT columns under seismic loads was studied through testing six columns which were subjected to a constant axial load in addition to a cyclic lateral load. Failure modes for through beam connection detail were identified through testing seven, two-thirds scale connection specimens. These tests were used to comprehend the force transfer mechanisms between steel beams and CFT columns and develop design provisions that could estimate the capacity of the various elements of the through beam connection detail.
引用
收藏
页码:213 / 222
页数:10
相关论文
共 50 条
  • [21] Design and behaviour of concrete-filled cold-formed stainless steel tube columns
    Ellobody, E
    Young, B
    ENGINEERING STRUCTURES, 2006, 28 (05) : 716 - 728
  • [22] Post-earthquake fire performance of square concrete-filled steel tube columns
    Wang, Yu-Hang
    Tang, Qi
    Su, Mei-Ni
    Tan, Ji-Ke
    Wang, Wei-Yong
    Lan, Yong-Sen
    Luo, Wei
    Zhou, Yang
    THIN-WALLED STRUCTURES, 2020, 154
  • [23] Axial compressive behavior of circular concrete-filled double steel tubular short columns
    Ci, Junchang
    Ahmed, Mizan
    Viet-Linh Tran
    Jia, Hong
    Chen, Shicai
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (02) : 259 - 276
  • [24] Fire resistance of square double-skin concrete-filled steel tubular columns and concrete-filled double steel tubular columns
    Zhu, Hongjie
    Ahmed, Mizan
    Li, Chenliu
    Kong, Xiao
    Chen, Shicai
    Yang, Qingtian
    Ghazali, Habibah
    Liang, Qing Quan
    ENGINEERING STRUCTURES, 2024, 319
  • [25] Analytical buckling of slender circular concrete-filled steel tubular columns with compliant interfaces
    Schnabl, S.
    Jelenic, G.
    Planinc, I.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 115 : 252 - 262
  • [26] Seismic Design of Concrete-Filled Circular Steel Bridge Piers
    Bruneau, Michel
    Marson, Julia
    JOURNAL OF BRIDGE ENGINEERING, 2004, 9 (01) : 24 - 34
  • [27] Design procedure to bearing concrete failure in concrete-filled steel tube columns with bolted shear connectors
    dos Santos, Lucas Ribeiro
    Caldas, Rodrigo Barreto
    Grilo, Lucas Figueiredo
    Carvalho, Hermes
    Fakury, Ricardo Hallal
    ENGINEERING STRUCTURES, 2021, 232
  • [28] Influence of concrete compaction on the strength of concrete-filled steel RHS columns
    Han, LH
    Yao, GH
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (06) : 751 - 767
  • [29] Behavior and calculation on concrete-filled steel CHS (circular hollow section) beam-columns
    Han, LH
    Yao, GH
    Zhao, XL
    STEEL AND COMPOSITE STRUCTURES, 2004, 4 (03) : 169 - 188
  • [30] Nonlinear analysis of circular concrete-filled steel tubular short columns under eccentric loading
    Liang, Qing Quan
    Fragomeni, Sam
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (02) : 159 - 169