A Comprehensive Comparison of Central Corneal Thickness Measurement

被引:38
作者
Huang, Jinhai [1 ,2 ]
Pesudovs, Konrad [3 ,4 ]
Yu, Ayong [1 ,2 ]
Wright, Thomas [3 ,4 ]
Wen, Daizong [1 ,2 ]
Li, Ming [1 ,2 ]
Yu, Ye [1 ,2 ]
Wang, Qinmei [1 ,2 ]
机构
[1] Minist Hlth Peoples Republ China, Hosp Eye, Wenzhou Med Coll, Key Lab Vis Sci, Wenzhou 325027, Zhejiang, Peoples R China
[2] Minist Hlth Peoples Republ China, Sch Optometry & Ophthalmol, Wenzhou 325027, Zhejiang, Peoples R China
[3] Flinders Med Ctr, NH&MRC Ctr Clin Eye Res, Dept Optometry & Vis Sci, Bedford Pk, SA, Australia
[4] Flinders Univ S Australia, Bedford Pk, SA, Australia
关键词
corneal thickness; optical coherence tomography; rotating Scheimpflug photography; LASIK; IN-SITU KERATOMILEUSIS; OPTICAL COHERENCE TOMOGRAPHY; ROTATING SCHEIMPFLUG CAMERA; STROMAL BED THICKNESS; ULTRASOUND PACHYMETRY; ORBSCAN-II; REFRACTIVE SURGERY; DIURNAL-VARIATION; OCULUS PENTACAM; FLAP THICKNESS;
D O I
10.1097/OPX.0b013e31821ffe2c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the repeatability and reproducibility of central corneal thickness (CCT) measurements by high-resolution rotating Scheimpflug imaging (Pentacam, Oculus) and Fourier-domain optical coherence tomography (RTvue-100, Optovue) after laser in situ keratomileusis (LASIK) and to compare the agreement with ultrasound pachymetry (USP). Methods. Forty-seven eyes of 47 patients after LASIK were included in the study. The first examiner took two successive Pentacam and RTvue CCT measurements, and this was repeated once again by the second examiner to assess intraobserver and interobserver repeatability and reproducibility. After performing non-contact examinations, the corneas were measured by USP to compare the level of agreement among the three devices. Results. All Pentacam(center), Pentacam(apex), Pentacam(thinnest), and RTvue CCT measurements demonstrated high intraobserver repeatability, with respective precision (1.96 within-subject standard deviation) and intraclass correlation coefficients of 7.52, 7.43, 7.55, and 3.81 mu m and 0.985, 0.986, 0.986, and 0.997; interobserver repeatability results were similar. All coefficients of variation were low: <1% for all measures. Compared with Pentacam and USP measurements, the RTvue measurement significantly underestimated CCT by a mean of 10.52 to 15.28 mu m (p < 0.001) and 9.17 mu m (p < 0.001), respectively. The agreement of USP with Pentacam and RTvue by Bland-Altman analysis spanned over 30 mu m. The agreement of Pentacam with RTvue spanned approximate 20 mu m. Conclusions. Both Pentacam imaging and RTvue Fourier-domain optical coherence tomography provide reliable and interchangeable measurement of CCT in post-LASIK corneas. However, they cannot be considered to be clinically interchangeable with USP. (Optom Vis Sci 2011;88:940-949)
引用
收藏
页码:940 / 949
页数:10
相关论文
共 52 条
  • [1] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) : 1729 - 1735
  • [2] Measurement error
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 312 (7047) : 1654 - 1654
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Bovelle R, 1999, ARCH OPHTHALMOL-CHIC, V117, P868
  • [5] *BRIT STAND I, 1994, 572511994 BS ISO BRI
  • [6] *BRIT STAND I, 1994, 572521994 BS ISO BRI
  • [7] Orbscan computerized topography: Attributes, applications, and limitations
    Cairns, G
    McGhee, CNJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) : 205 - 220
  • [8] Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry
    Chen, Shihao
    Huang, Jinhai
    Wen, Daizong
    Chen, Wuhe
    Huang, David
    Wang, Qinmei
    [J]. ACTA OPHTHALMOLOGICA, 2012, 90 (05) : 449 - 455
  • [9] Comparison of corneal thickness measurements by ultrasound and scheimpflug photography in eyes that have undergone laser in situ keratomileusis
    Ciolino, Joseph B.
    Khachikian, Steven S.
    Belin, Michael W.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (01) : 75 - 80
  • [10] Comparison of residual stromal bed and flap thickness in primary and repeat laser in situ keratomileusis in myopic patients
    Das, Sujata
    Sullivan, Laurence J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) : 2080 - 2084