Multi-objective optimization of an externally finned two-phase closed thermosyphon using response surface methodology

被引:24
作者
Alizadeh, M. [1 ]
Ganji, D. D. [1 ]
机构
[1] Babol Noushirvani Univ Technol, Dept Mech Engn, Babol Sar, Iran
关键词
Externally finned thermosyphon; Empirical correlation; Heat transfer coefficient; Central Composite Design (CCD); Response Surface Methodology (RSM); Optimization; HEAT-TRANSFER CHARACTERISTICS; THERMAL PERFORMANCE; FLUIDS;
D O I
10.1016/j.applthermaleng.2020.115008
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, an experimental research is conducted on the thermal performance (TP) of an externally finned thermosyphon working with water. The thermosyphon is made of copper and consists of the evaporator part with 200 mm length, the adiabatic part with 100 mm length, and the condenser part with 200 mm length. Longitudinal fins with 200 mm length, 5 mm width, 0.7 mm thickness and rectangular cross section are joined to the external surface of the condenser. Empirical correlations are developed for predicting the heat transfer coefficients of the evaporator (h(e)) and condenser (h(c)) as functions of thermosyphon operating parameters such as the heat input, filling ratio, coolant flow rate, and the number of fins. The experiments are designed using Central Composite Design (CCD) and conducted by measuring the thermosyphon wall temperature and temperature difference of the coolant. The operating parameters of thermosyphon are optimized using Response Surface Methodology (RSM) to achieve the highest performance. Results reveal that the presented correlations by RSM can predict the h(e) and h(e) with high accuracy. Moreover, the highest h(e) of 4554 W/m(2) K and highest h(e) of 504.314 W/m(2) K are achieved under the optimum values of 300 W of heat input, 35.13% of filling ratio, 219.3 ml/min of the coolant flow rate, and 8 fins.
引用
收藏
页数:10
相关论文
共 30 条
[21]   Experimental investigations of heat transfer from an internally finned two phase closed thermosyphon [J].
Naresh, Y. ;
Balaji, C. .
APPLIED THERMAL ENGINEERING, 2017, 112 :1658-1666
[22]   Optimization of Process Parameters of Helical Grooved Heat pipe Using Response Surface Methodology [J].
Nookaraju, B. Ch. ;
Kurmarao, P. S. V. ;
Nagasarada, S. ;
Karthikeyan, R. ;
Vinay, A. .
MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) :5262-5271
[23]   Numerical simulation and experimental verification on thermal performance of a novel fin-plate thermosyphon [J].
Peng, Hao ;
Ling, Xiang ;
Li, Juan .
APPLIED THERMAL ENGINEERING, 2012, 40 :181-188
[24]   Smart optimization of a thermosyphon heat pipe for an evacuated tube solar collector using response surface methodology (RSM) [J].
Sarafraz, M. M. ;
Tlili, I. ;
Tian, Zhe ;
Bakouri, Mohsen ;
Safaei, Mohammad Reza .
PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2019, 534
[25]   CHARACTERISTICS OF 2-PHASE CLOSED THERMOSIPHONS FOR MEDIUM-TEMPERATURE HEAT-RECOVERY APPLICATIONS [J].
SAUCIUC, I ;
AKBARZADEH, A ;
JOHNSON, P .
HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (07) :631-640
[26]   INVESTIGATION OF HEAT-TRANSFER CHARACTERISTICS OF A 2-PHASE CLOSED THERMOSYPHON [J].
SHIRAISHI, M ;
KIKUCHI, K ;
YAMANISHI, T .
JOURNAL OF HEAT RECOVERY SYSTEMS, 1981, 1 (04) :287-297
[27]  
Taylor J, 1997, The Study of Uncertainties in Physical Measurements, VII
[28]  
Van P., 2008, Liquid-Vapor Phase-Change Phenomena, V2nd
[29]   Experimental investigation and economic analysis of gravity heat pipe exchanger applied in communication base station [J].
Zhang, L. Y. ;
Liu, Y. Y. ;
Guo, X. ;
Meng, X. Z. ;
Jin, L. W. ;
Zhang, Q. L. ;
Hu, W. J. .
APPLIED ENERGY, 2017, 194 :499-507
[30]   PVT type of the two-phase loop mini tube thermosyphon solar water heater [J].
Ziapour, Behrooz M. ;
Khalili, Mohsen Bagheri .
ENERGY CONVERSION AND MANAGEMENT, 2016, 129 :54-61