Biomechanical Evaluation of the Effects of Implant Neck Wall Thickness and Abutment Screw Size: A 3D Nonlinear Finite Element Analysis

被引:16
作者
Jeng, Ming-Dih [1 ]
Lin, Yang-Sung [2 ]
Lin, Chun-Li [2 ]
机构
[1] Far Eastern Mem Hosp, Dept Dent, New Taipei 220, Taiwan
[2] Natl Yang Ming Univ, Dept Biomed Engn, Taipei 112, Taiwan
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 10期
关键词
biomechanics; dental implant; finite element analysis; implant neck wall; abutment screw; BONE QUALITY; MORSE TAPER; CONFIGURATIONS; CONNECTIONS; MECHANICS; FORCES; LEVEL;
D O I
10.3390/app10103471
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we evaluate the influence of implant neck wall thickness and abutment screw size on alveolar bone and implant component biomechanical responses using nonlinear finite element (FE) analysis. Twelve internal hexagon Morse taper implant-abutment connection FE models with three different implant sizes (diameters 4, 5, and 6 mm), secured with 1.4, 1.6, and 1.8 mm abutment screws to fit with three unilateral implant neck wall thicknesses of 0.45, 0.50, and 1.00 mm, were constructed to perform simulations. Nonlinear contact elements were used to simulate realistic interface fixation within the implant system. A 200 N concentrated force was applied toward the center of a hemispherical load cap and inclined 30 degrees relative to the implant axis as the loading condition. The simulation results indicated that increasing the unilateral implant neck wall thickness from 0.45 to 1.00 mm can significantly decrease implant, abutment, and abutment screw stresses and bone strain, decreased to 58%, 48%, 54%, and 70%, respectively. Variations in abutment screw size only significantly influenced abutment screw stress, and the maximum stress dissipation rates were 10% and 29% when the diameter was increased from 1.4 to 1.6 and 1.8 mm, respectively. We conclude that the unilateral implant neck wall thickness is the major design factor for the implant system and implant neck wall thickness in effectively decreasing implant, abutment, and abutment screw stresses and bone strain.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study
    Tonin, Bruna S. H.
    Fu, Jing
    He, Yiting
    Ye, Ning
    Chew, Hooi Pin
    Fok, Alex
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 142
  • [22] Biomechanical analysis and comparison of 12 dental implant systems using 3D finite element study
    Liang, Rui
    Guo, Weihua
    Qiao, Xiangchen
    Wen, Hailin
    Yu, Mei
    Tang, Wei
    Liu, Lei
    Wei, Yongtao
    Tian, Weidong
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (12) : 1340 - 1348
  • [23] Biomechanical Evaluation of Clival Screw Fixation for Occipitocervical Instablity: A Finite Element Analysis
    Lin, Weipeng
    Zheng, Jianying
    Zhang, Meichao
    Xu, Panjie
    Xiao, Hang
    Ji, Wei
    ORTHOPAEDIC SURGERY, 2025, 17 (02) : 583 - 592
  • [24] Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
    Ferreira Koyama Takahashi, Jessica Mie
    Dayrell, Andreza Costa
    Xediek Consani, Rafael Leonardo
    de Arruda Nobilo, Mauro Antonio
    Pessanha Henriques, Guilherme Elias
    Mesquita, Marcelo Ferraz
    Journal of Oral Implantology, 2015, 41 (02) : 133 - 137
  • [26] Effect of lubricant on the reliability of dental implant abutment screw joint: An in vitro laboratory and three-dimension finite element analysis
    Wu, Tingting
    Fan, Hongyi
    Ma, Ruiyang
    Chen, Hongyu
    Li, Zhi
    Yu, Haiyang
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 75 : 297 - 304
  • [27] A 3D Nonlinear Finite Element Study on Biomechanical Behavior of Dental Implants
    Wu, Ting
    Liao, Wenhe
    Dai, Ning
    MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 3263 - 3267
  • [28] Non-linear 3D Evaluation of Different Oral Implant-Abutment Connections
    Streckbein, P.
    Streckbein, R. G.
    Wilbrand, J. F.
    Malik, C. Y.
    Schaaf, H.
    Howaldt, H. P.
    Flach, M.
    JOURNAL OF DENTAL RESEARCH, 2012, 91 (12) : 1184 - 1189
  • [29] Effects of Screw- and Cement-Retained Implant-Supported Prostheses on Bone: A Nonlinear 3-D Finite Element Analysis
    Silva, Guilherme Carvalho
    de Andrade, Guilherme Martins
    Pinto Coelho, Rodrigo Carvalho
    Cornacchia, Tulimar Machado
    de Magalhaes, Claudia Silami
    Moreira, Allyson Nogueira
    IMPLANT DENTISTRY, 2015, 24 (04) : 464 - 471
  • [30] Evaluation of postoperative dental implant primary stability using 3D finite element analysis
    Pammer, David
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (03) : 280 - 287