Development of a sensor device with polymer-coated piezoelectric micro-cantilevers for detection of volatile organic compounds

被引:7
|
作者
Ahmed, Waqar M. [1 ]
Steenwelle, Ruud J. A. [2 ]
Knobel, Hugo H. [3 ]
Davie, Alan [4 ]
Steijvers, Ron [4 ]
Verhoeckx, Fred [4 ]
Goodacre, Royston [5 ]
Fowler, Stephen J. [1 ,6 ]
Rijnders, A. J. H. M. [2 ]
Nijsen, Tamara M. [4 ]
机构
[1] Univ Manchester, Fac Biol Med & Hlth, Sch Biol Sci, Manchester, Lancs, England
[2] Univ Twente, Fac Sci & Technol, Enschede, Netherlands
[3] Eurofins Mat Sci Netherlands BV, Eindhoven, Netherlands
[4] Royal Philips BV, Philips Res, Eindhoven, Netherlands
[5] Univ Liverpool, Inst Integrat Biol, Dept Biochem, Liverpool, Merseyside, England
[6] Manchester Univ Hosp NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Wythenshawe, England
基金
欧盟第七框架计划;
关键词
volatile organic compounds; sensor; cantilever; breathdx; BREATH ANALYSIS; METABOLOMICS; THRESHOLD; DIAGNOSIS; TUBE; MS;
D O I
10.1088/1361-6501/ab4f2f
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Exhaled breath contains thousands of volatile organic compounds (VOCs), some of which have been associated with respiratory disease. We describe a sensor device with an array of eight polymer-coated piezoelectric micro-cantilevers (two of each polyacrylic acid, polyethylenimine and polyethylene glycol and two uncoated cantilevers) and an electronic resonant frequency readout, designed for analysis of VOCs. We have measured the system's response to temperature (24 degrees C to 40 degrees C), pressure (200 mmHg to 760 mmHg), and humidity (10% to 50% RH), evaluated the reproducibility of measurements between micro-cantilevers (n = 3), and tested the stability of the system over six months. By measuring the frequency shift of the resonating micro-cantilevers, and using the inflection point of a fitted sigmoid model, we show that acetone, ethanol, octane are distinguishable from one another, with a measurement limited of detection of 1568, 383, and 87 ppmv, respectively. From interpolation of the electronic readout, we found the lowest estimated measurement to be 5 ppmv (acetone on polyacrylic acid). We have also shown that polar mixture (acetone, ethanol, and water) and non- polar mixture (increasing octane concentration and decreasing polar mixture constituents) can be differentiated.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Detection of volatile organic compounds (VOCs) with polymer-coated cantilevers
    Maute, M
    Raible, S
    Prins, FE
    Kern, DP
    Ulmer, H
    Weimar, U
    Göpel, W
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 58 (1-3) : 505 - 511
  • [2] Development of a fluorosiloxane polymer-coated optical fibre sensor for detection of organic volatile compounds
    Silva, Lurdes I. B.
    Rocha-Santos, Teresa A. P.
    Duarte, A. C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01) : 280 - 289
  • [3] Detection of volatile organic compounds (VOCs) with polymer coated cantilevers
    Maute, M
    Raible, S
    Ulmer, H
    Prins, FE
    Weimar, U
    Kern, DP
    Göpel, W
    EUROSENSORS XII, VOLS 1 AND 2, 1998, : 1083 - 1086
  • [4] Detection of Volatile Organic Compounds by Analyses of Polymer-Coated Quartz Crystal Microbalance Sensor Arrays
    Kimura, Mutsumi
    Liu, Ye
    Sakai, Ryosuke
    Sato, Seiko
    Hirai, Toshihiro
    Fukawa, Tadashi
    Mihara, Takashi
    SENSORS AND MATERIALS, 2011, 23 (07) : 359 - 368
  • [5] The selective flow of volatile organic compounds in conductive polymer-coated microchannels
    Faramarz Hossein-Babaei
    Ali Hooshyar Zare
    Scientific Reports, 7
  • [6] The selective flow of volatile organic compounds in conductive polymer-coated microchannels
    Hossein-Babaei, Faramarz
    Zare, Ali Hooshyar
    SCIENTIFIC REPORTS, 2017, 7
  • [7] Characterization of the gas sensors based on polymer-coated resonant microcantilevers for the detection of volatile organic compounds
    Dong, Ying
    Gao, Wei
    Zhou, Qin
    Zheng, Yi
    You, Zheng
    ANALYTICA CHIMICA ACTA, 2010, 671 (1-2) : 85 - 91
  • [8] Distributed MEMS Mass-Sensor Based on Piezoelectric Resonant Micro-Cantilevers
    Joshi, Priyanka
    Kumar, Sanjeev
    Jain, V. K.
    Akhtar, Jamil
    Singh, Jitendra
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2019, 28 (03) : 382 - 389
  • [9] Selectivity of chemical sensors based on micro-cantilevers coated with thin polymer films
    Betts, TA
    Tipple, CA
    Sepaniak, MJ
    Datskos, PG
    ANALYTICA CHIMICA ACTA, 2000, 422 (01) : 89 - 99
  • [10] Polymer-coated sensor arrays for organic vapor detection.
    Grate, JW
    Kaganove, SN
    Patrash, SJ
    Wise, BM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 42 - AGRO