Bond behaviour of CFRP/steel strap joints exposed to overloading fatigue and wetting/drying cycles

被引:37
|
作者
Wang, Yi [1 ]
Li, Junhui [1 ]
Deng, Jun [1 ]
Li, Song [1 ]
机构
[1] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Guangdong, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
CFRP; Bond behaviour; Overloading fatigue; Wetting/drying cycles; Durability; METALLIC BEAMS; ENVIRONMENTAL DURABILITY; FRP/STEEL JOINTS; STEEL MEMBERS; CFRP PLATES; CARBON; FRP; CORROSION; STRENGTH; MOISTURE;
D O I
10.1016/j.engstruct.2018.05.112
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Carbon fibre reinforced polymer (CFRP) has been widely used in strengthening of deficient steel structures in subtropical regions following their application in concrete structure rehabilitation. However, after the strengthening, both hygrothermal conditions and overloading fatigue can further promote the mechanical degradation of the strengthened structures, and the tendency remains unclear. Therefore, to predict the service life of steel structures after CFRP strengthening, the bond behaviour of CFRP-strengthened steel plates that are affected by overloading fatigue damage and/or wetting/drying cycles (WDCs) with 3.5 wt% NaCl solution was investigated in this study. In total, 12 CFRP/steel strap joints were tested in six cases, where six specimens experienced overloading damage by axial fatigue tensile loading. Then, both specimens with and without pre damage were exposed to WDCs (0, 90 and 180). After WDC exposure, the tensile tests were conducted. The load strain curves, tensile-bearing capacities, failure modes and interfacial stress distributions were obtained. As observed, with increasing WDCs, the strength of the overloading fatigue-damaged specimens continuously decreased. However, the strength of the specimens without overloading damage decreased during the first 90 WDCs and then slightly increased during the next 90 WDCs. In addition, a simple expression of the maximum interfacial principle stress at the gap location of the CFRP/steel strap joints was developed. A model based on the maximum stress was proposed to evaluate the long-term bond strength degradation of CFRP-strengthened steel structures under overloading fatigue and/or WDC conditions, and good consistency was reached with the test results.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [1] Experimental study of notched steel beams strengthened with a CFRP plate subjected to overloading fatigue and wetting/drying cycles
    Li, Junhui
    Deng, Jun
    Wang, Yi
    Guan, Jianji
    Zheng, Hengzhong
    COMPOSITE STRUCTURES, 2019, 209 : 634 - 643
  • [2] Flexural behaviour of notched steel beams strengthened with a prestressed CFRP plate subjected to fatigue damage and wetting/drying cycles
    Li, Junhui
    Zhu, Miaochang
    Deng, Jun
    ENGINEERING STRUCTURES, 2022, 250
  • [3] Fatigue behavior of notched steel beams strengthened by a prestressed CFRP plate subjected to wetting/drying cycles
    Deng, Jun
    Li, Junhui
    Zhu, Miaochang
    COMPOSITES PART B-ENGINEERING, 2022, 230
  • [4] A universal solution of the bond behaviour between CFRP-steel double strap joints considering steel yielding
    Yu, Yang-Zhe
    Tam, Lik-ho
    Wu, Chao
    COMPOSITE STRUCTURES, 2023, 304
  • [5] Effects of bondline defects on the bond behaviour of CFRP-steel double strap joints
    Wu, Chao
    Yu, Yang-Zhe
    Tam, Lik-ho
    He, Li
    COMPOSITE STRUCTURES, 2023, 308
  • [6] Failure Assessment of Steel/CFRP Double Strap Joints
    Majidi, Hamid Reza
    Razavi, Seyed Mohammad Javad
    Berto, Filippo
    METALS, 2017, 7 (07):
  • [7] Durability of steel/CFRP double strap joints exposed to sea water, cyclic temperature and humidity
    Tien-Cuong Nguyen
    Bai, Yu
    Zhao, Xiao-Ling
    Al-Mahaidi, Riadh
    COMPOSITE STRUCTURES, 2012, 94 (05) : 1834 - 1845
  • [8] Fatigue behaviour of tensile steel/CFRP joints
    Colombi, Pierluigi
    Fava, Giulia
    COMPOSITE STRUCTURES, 2012, 94 (08) : 2407 - 2417
  • [9] Effect of corrosion on the tensile and fatigue performance of CFRP strand Sheet/Steel double strap joints
    Ren, Xiang
    Sherif, Muhammad M.
    Wei, Yaoyao
    Lyu, Yuhui
    Sun, Yamin
    Ozbulut, Osman E.
    ENGINEERING STRUCTURES, 2022, 260
  • [10] Evaluation of bond properties of degraded CFRP-strengthened double strap joints
    Batuwitage, Chamila
    Fawzia, Sabrina
    Thambiratnam, David
    Al-Mahaidi, Riadh
    COMPOSITE STRUCTURES, 2017, 173 : 144 - 155