Correlation between space charge distribution and water-tree location in aged XLPE cable

被引:24
作者
Suzuki, K [1 ]
Tanaka, Y
Takada, T
Ohki, Y
Takeya, C
机构
[1] Musashi Inst Technol, Tokyo 158, Japan
[2] Waseda Univ, Tokyo 160, Japan
[3] Tatsuta Elect Wire & Cable Co Ltd, Osaka, Japan
关键词
D O I
10.1109/94.910428
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The correlation between charge distribution in an aged crosslinked polyethylene (XLPE) cable and the location of water trees has been studied. The space charge radial distributions at different angle in the insulating wall of a service-aged XLPE coaxial cable, induced by application of a de stress, were measured using the pulsed electroacoustic (PEA) method. Furthermore, a cross section of sliced insulating wall was observed with an optical microscope to compare with the radial space charge distribution. The cable under investigation was electrically aged in service at 6.6 kV ac for 25 years in wet conditions. Water trees were found at the position in which space charge was observed. On the other hand, no water tree was found at the position in which the space charge was not observed. Judging from these results, the space charge measurement seems to be useful for the diagnosis of water trees in aged cables.
引用
收藏
页码:78 / 81
页数:4
相关论文
共 50 条
[11]   Influence of water-tree degradation on electroluminescence spectrum in XLPE [J].
Watanabe, M. ;
Mito, T. ;
Muramoto, Y. ;
Shimizu, N. .
2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, :720-723
[12]   Space Charge Formation and Physicochemical Properties of Aged XLPE Cable Insulation [J].
Li, Shengtao ;
Li, Weiwei ;
Li, Jianying ;
Wang, Xia ;
Li, Huan ;
Jing, Yu .
PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, :408-411
[13]   Physicochemical Origin of Space Charge Dynamics for Aged XLPE Cable Insulation [J].
Li, Weiwei ;
Li, Jianying ;
Wang, Xia ;
Li, Shengtao ;
Chen, George ;
Zhao, Jiankang ;
Ouyang, Benhong .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (02) :809-820
[14]   New residual-charge measurement for water-tree deteriorated power cable [J].
Kon, H ;
Wantanabe, K ;
Miyajima, K ;
Uchida, K .
PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, :77-82
[15]   Micro-analysis of water-tree in XLPE by synchrotron radiation [J].
Research and Development Div., Hitachi Cable, Ltd., 5-1-1, Hitaka-cho, Hitachi 319-1414, Japan ;
不详 .
IEEJ Trans. Fundam. Mater., 2007, 6 (328-334+8) :328-334+8
[16]   Insulation evaluation of water-tree aged 10 kV XLPE cables using thermal step method [J].
Du, Bo-Xue ;
Ma, Zong-Le ;
Gao, Yu ;
Cheng, Xin-Xin ;
Yang, Lin ;
Li, Hong-Bo .
Gaodianya Jishu/High Voltage Engineering, 2011, 37 (01) :143-149
[17]   Measurement of space charge distribution in XLPE cable insulation at high temperature [J].
Kanno, T ;
Uozumi, T ;
Inoue, Y .
CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, :85-88
[18]   Space Charge Distribution in an Extruded Cable Aged in Tap Water for 3 Years [J].
Liu, Rongsheng ;
Bergkvist, Mikael ;
Jeroense, Marc .
2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, :438-+
[19]   OXIDATION AND WATER TREE FORMATION IN SERVICE-AGED XLPE CABLE INSULATION [J].
GARTON, A ;
BAMJI, S ;
BULINSKI, A ;
DENSLEY, J .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (04) :405-412
[20]   Study on Water Tree Degradation Diagnosis of XLPE Cable Using Charge Radar [J].
Kim, MyonHwan ;
Unoki, Taketo ;
Murakami, Yoshinobu ;
Nagao, Masayuki ;
Kurihara, Takashi ;
Okamoto, Tatsuki ;
Miyajima, Kazuhisa ;
Uchida, Katsumi ;
Hozumi, Naohiro .
PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, :148-151