Best Practices: Consensus on Performing Positron Emission Tomography-Computed Tomography for Radiation Therapy Planning and for Therapy Response Assessment

被引:4
作者
Blodgett, Todd [1 ]
机构
[1] Fdn Radiol Grp, Pittsburgh, PA 15208 USA
关键词
STANDARDIZED UPTAKE VALUE; F-18 FDG PET/CT; NON-HODGKINS-LYMPHOMA; TIME-POINT PET/CT; CELL LUNG-CANCER; BREAST-CANCER; NECK-CANCER; NEOADJUVANT CHEMOTHERAPY; EARLY PREDICTION; UPTAKE VALUES;
D O I
10.1053/j.sult.2010.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The incorporation of positron emission tomography-computed tomography (PET-CT) into oncological imaging has expanded rapidly since the hybrid scanners were introduced approximately 10 years ago. PET-CT is becoming the standard of practice for the imaging diagnosis and staging of most cancers. Since its introduction, hardware-registered PET and CT images produced by a PET-CT scan were recognized as valuable not only for detection, staging and restaging applications but also for optimizing radiation treatment planning. Even before the introduction of PET-CT, the value of metabolic imaging with the use of FDG PET was recognized as a potentially powerful means of assessing response to various therapies, particularly chemotherapy regimens. To better understand the optimal use of PET-CT in radiation therapy planning and the role of PET-CT in assessing response to therapy, we invited experts from various disciplines to participate in focus group meetings that took place in 2009 and 2010. The Symposia focused on the use of PET-CT imaging in radiation therapy planning (2009) and the use of PET-CT in therapy response assessment (2010). This article will summarize areas of consensus reached by the group regarding many of the discussion topics. The consensus summaries covered in this article are meant to provide direction for future discussions on how to improve the application of this hybrid modality to optimize patient care. © 2010 Elsevier Inc.
引用
收藏
页码:506 / 515
页数:10
相关论文
共 129 条
  • [1] Does 18F-FDG PET/CT Improve the Detection of Posttreatment Recurrence of Head and Neck Squamous Cell Carcinoma in Patients Negative for Disease on Clinical Follow-up?
    Abgral, Ronan
    Querellou, Solene
    Potard, Gael
    Le Roux, Pierre-Yves
    Le Duc-Pennec, Alexandra
    Marianovski, Remi
    Pradier, Olivier
    Bizais, Yves
    Kraeber-Bodere, Francoise
    Salaun, Pierre Y.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) : 24 - 29
  • [2] Interpretation and reporting of positron emission tomography-computed tomographic scans
    Agress, Harry, Jr.
    Wong, Terence Z.
    Shreve, Paul
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 2008, 29 (04) : 283 - 290
  • [3] False positive 18F-FDG-PET/CT in a patient after talc pleurodesis
    Ahmadzadehfar, Hojjat
    Palmedo, Holger
    Strunk, Holger
    Biersack, Hans-Juergen
    Habibi, Elham
    Ezziddin, Samer
    [J]. LUNG CANCER, 2007, 58 (03) : 418 - 421
  • [4] Dual-Time F-18 FDG-PET/CT Imaging for Diagnosis of Occult Non-Hodgkin Lymphoma in a Patient With Esophageal Cancer
    Ahmadzadehfar, Hojjat
    Sabet, Amir
    Naeke, Kristina
    Hinterthaner, Brigitte
    Biersack, Hans-Juergen
    Ezziddin, Samer
    [J]. CLINICAL NUCLEAR MEDICINE, 2009, 34 (03) : 168 - 170
  • [5] 18F-FDG uptake in an ovary containing a hemorrhagic corpus luteal cyst:: False-positive PET/CT in a patient with cervical carcinoma
    Ames, J
    Blodgett, T
    Meltzer, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) : 1057 - 1059
  • [6] F-18 FDG PET/CT Findings in Pulmonary Necrotizing Sarcoid Granulomatosis
    Arfi, Julia
    Kerrou, Khaldoun
    Traore, Samba
    Huchet, Virginie
    Bolly, Antoine
    Antoine, Martine
    Delaunois, Luc
    Borght, Thierry Vander
    Talbot, Jean-Noel
    [J]. CLINICAL NUCLEAR MEDICINE, 2010, 35 (09) : 697 - 700
  • [7] Breast imaging with positron emission tomography and fluorine-18 fluorodeoxyglucose:: Use and limitations
    Avril, N
    Rosé, CA
    Schelling, M
    Dose, J
    Kuhn, W
    Bense, S
    Weber, W
    Ziegler, S
    Graeff, H
    Schwaiger, M
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2000, 18 (20) : 3495 - 3502
  • [8] Monitoring response to treatment in patients utilizing PET
    Avril, NE
    Weber, WA
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (01) : 189 - +
  • [9] Response to Therapy in Breast Cancer
    Avril, Norbert
    Sassen, Stefanie
    Roylance, Rebecca
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 : 55S - 63S
  • [10] False positivity of FDG-PET/CT in a child with Hodgkin disease
    Beker, Dildar Bahar
    Berrak, Su Gulsun
    Canpolat, Cengiz
    Tugtepe, Halil
    Ones, Tunc
    Tecimer, Tulay
    [J]. PEDIATRIC BLOOD & CANCER, 2008, 50 (04) : 881 - 883