Load transfer along the bone-dental implant interface

被引:61
作者
Faegh, Samira [1 ]
Mueftue, Sinan [1 ]
机构
[1] Northeastern Univ, Dept Mech Engn, Boston, MA 02115 USA
关键词
Dental implants; Interfacial stresses; Load transfer; Osseointegration; External threads; Implant contour; ELEMENTS;
D O I
10.1016/j.jbiomech.2010.02.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper the variation of normal and shear stresses along a path defined on the bone-dental implant interface is investigated. In particular, the effects of implant diameter, collar length and slope, body length, and the effects of four different types of external threads on the interfacial stress distribution are studied. The geometry of the bone is digitized from a CT scan of a mandibular incisor and the surrounding bone. The bone and the implant are assumed to be perfectly bonded. The finite element method with 2D plane strain assumption is used to compute interfacial stresses. Highest continuous interfacial stresses are encountered in the region where the implant collar engages the cortical region, and near the apex of the implant in the subcortical region. Stress concentrations in the interfacial stresses occur near the geometric discontinuities on the implant contour, and jumps in stress values occur where the elastic modulus of the bone transitions between the cortical and trabecular bone values. Among the six contour parameters, the slope and the length of the implant collar, and the implant diameter influence the interfacial stress levels the most, and the effects of changing these parameters are significantly noticed only in the cortical bone (alveolar ridge) area. External threads cause significant stress concentrations in interfacial stresses in otherwise smoothly varying regions. This work shows that the presence of external threads could cause significant variations in both normal and shear stresses along the bone-implant interface, but not reduction in shear stress as previously thought. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1761 / 1770
页数:10
相关论文
共 28 条
  • [1] Akpinar I, 1996, Quintessence Int, V27, P11
  • [2] Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
  • [3] EDGE-BONDED DISSIMILAR ORTHOGONAL ELASTIC WEDGES UNDER NORMAL AND SHEAR LOADING
    BOGY, DB
    [J]. JOURNAL OF APPLIED MECHANICS, 1968, 35 (03): : 460 - &
  • [4] Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis
    Bozkaya, D
    Muftu, S
    Muftu, A
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (06) : 523 - 530
  • [5] Mechanics of the tapered interference fit in dental implants
    Bozkaya, D
    Müftü, S
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (11) : 1649 - 1658
  • [6] BRUNSKI JB, 1983, ADV BIOENG, P43
  • [7] Carter D., 2001, SKELETAL FUNCTION FO
  • [8] Predictions of bone remodeling around dental implant systems
    Chou, Hsuan-Yu
    Jagodnik, John J.
    Mueftue, S.
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (06) : 1365 - 1373
  • [9] Evaluation of design parameters of osseointegrated dental implants using finite element analysis
    Chun, HJ
    Cheong, SY
    Han, JH
    Heo, SJ
    Chung, JP
    Rhyu, IC
    Choi, YC
    Baik, HK
    Ku, Y
    Kim, MH
    [J]. JOURNAL OF ORAL REHABILITATION, 2002, 29 (06) : 565 - 574
  • [10] delValle V, 1997, INT J ORAL MAX IMPL, V12, P200