Influence of aortic neck characteristics on successful aortic wall penetration of EndoAnchors in therapeutic use during endovascular aneurysm repair

被引:24
|
作者
Goudeketting, Seline R. [1 ,2 ]
van Noort, Kim [1 ,2 ]
Ouriel, Kenneth [3 ]
Jordan, William D., Jr. [4 ]
Panneton, Jean M. [5 ]
Slump, Cornelis H. [2 ]
de Vries, Jean-Paul P. M. [1 ]
机构
[1] St Antonius Hosp, Dept Vasc Surg, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[2] Univ Twente, Fac Sci & Technol, Dept Tech Med, Enschede, Netherlands
[3] Syntactx, New York, NY USA
[4] Emory Univ, Sch Med, Dept Vasc Surg, Atlanta, GA USA
[5] Eastern Virginia Med Sch, Div Vasc Surg, Norfolk, VA 23501 USA
关键词
EndoAnchor; Endovascular aneurysm repair; Abdominal aortic aneurysm; Type IA endoleak; Aneurysm neck; ENDOGRAFT FIXATION; IA ENDOLEAK; ANATOMY; HOSTILE; EVAR; PLACEMENT; MIGRATION;
D O I
10.1016/j.jvs.2018.01.039
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study sought to quantify EndoAnchor (Medtronic Vascular, Santa Rosa, Calif) penetration into the aortic wall in patients undergoing endovascular abdominal aortic aneurysm repair and to assess predictors of successful penetration and its relationship to postprocedural type IA endoleak. Methods: A subset of patients from the Aneurysm Treatment Using the Heli-FX Aortic Securement System Global Registry (ANCHOR) were included if they met the following criteria: the indication for EndoAnchor use was to treat a type IA endoleak, and postprocedure contrast-enhanced computed tomography (CT) scans of sufficient quality were available for core laboratory review. Patients undergoing implantation of cuffs or stents during the EndoAnchor implantation procedure were excluded. Baseline anatomic characteristics were recorded. The cohort was divided into patients with and without persistent type IA endoleaks at the first postoperative CT scan. Penetration of each EndoAnchor measured on this CT scan was defined as good penetration when the EndoAnchor penetrated >= 2 mm into the aortic wall, borderline penetration when EndoAnchor penetration was <2mmor a gap remained between the endograft and aortic wall, or no penetration when the EndoAnchor did not penetrate into the aortic wall. Differences between the groups were analyzed with the Mann-Whitney U test or Fisher exact test. Multivariate analyses were performed to identify independent predictors of EndoAnchor penetration, and procedural success was defined by absence of type IA endoleak. Results: Eighty-six patients of the primary (n = 61 [71%]) and revision (n = 25 [29%]) arms of the ANCHOR registry were included. There were 53 (62%) without and 33 (38%) with persistent type IA endoleaks on the first postprocedural CT scan. The median number of EndoAnchors with good penetration was significantly greater in the cohort without endoleaks, 4 (interquartile range, 3-5) vs 3 (interquartile range, 1.5-4), respectively (P = .002). A multivariate model for EndoAnchor penetration identified use of a Medtronic Endurant endograft as a factor associated with good penetration (P = .001), whereas poor penetration was associated with a larger aortic neck diameter 10 mm distal to the lowest renal artery (P < .001) and greater proximal neck calcium thickness (P = .004). EndoAnchor penetration was the only variable that attained significance (P < .001) in the multivariate model for successful treatment of a type IA endoleak. Conclusions: Adequate EndoAnchor penetration into the aortic wall is less likely when the aortic neck diameter is large or when the neck contains significant mural calcium. No penetration of the EndoAnchor was the only factor predictive of postprocedural type IA endoleak. This study stresses the importance of careful selection of patients based on preoperative assessment of the infrarenal neck on CT angiography and emphasizes careful deployment of EndoAnchors into the aortic wall to improve successful treatment of type IA endoleaks.
引用
收藏
页码:1007 / 1016
页数:10
相关论文
共 50 条
  • [41] Successful endovascular repair in two cases of graft limb occlusion after endovascular aneurysm repair for abdominal aortic aneurysms
    Katsuyuki Hoshina
    Masaaki Kato
    Akiyoshi Mikuriya
    Nobukazu Ohkubo
    Surgery Today, 2010, 40 : 487 - 490
  • [42] Successful endovascular repair in two cases of graft limb occlusion after endovascular aneurysm repair for abdominal aortic aneurysms
    Hoshina, Katsuyuki
    Kato, Masaaki
    Mikuriya, Akiyoshi
    Ohkubo, Nobukazu
    SURGERY TODAY, 2010, 40 (05) : 487 - 490
  • [43] A Systematic Review of Proximal Neck Dilatation After Endovascular Repair for Abdominal Aortic Aneurysm
    Kouvelos, George N.
    Oikonomou, Kyriakos
    Antoniou, George A.
    Verhoeven, Eric L. G.
    Katsargyris, Athanasios
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (01) : 59 - 67
  • [44] Use of intravascular ultrasound in endovascular repair of abdominal aortic aneurysm
    Dzieciuchowicz, Lukasz
    Krzyzanski, Radoslaw
    Nowak, Anita
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2020, 16 (02): : 202 - 205
  • [45] Synchronous abdominal aortic aneurysm and colorectal cancer. The therapeutic dilemma in the era of endovascular aortic aneurysm repair
    Bali, C. D.
    Harissis, H.
    Matsagas, M. I.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2009, 50 (03) : 373 - 379
  • [46] Selective aneurysmal sac neck-targeted embolization during endovascular repair of abdominal aortic aneurysm with hostile neck anatomy
    Lifeng Zhang
    Yongjiang Tang
    Jiantao Wang
    Xianjun Liu
    Yang Liu
    Wei Zeng
    Chunshui He
    Journal of Cardiothoracic Surgery, 19
  • [47] An observational assessment of aortic deformation during infrarenal and complex endovascular aortic aneurysm repair
    Witheford, Miranda
    Borghese, Ottavia
    Mastracci, Tara M.
    Maurel, Blandine
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (03) : 645 - +
  • [48] Successful transfemoral aortic valve implantation through aortic stent graft after endovascular repair of abdominal aortic aneurysm
    Kawashima H.
    Watanabe Y.
    Kozuma K.
    Cardiovascular Intervention and Therapeutics, 2017, 32 (2) : 165 - 169
  • [49] An Analysis of Variables Affecting Aortic Neck Length with Implications for Fenestrated Endovascular Repair of Abdominal Aortic Aneurysm
    Stark, Madeline
    Suresh, Adithya
    Alexander, Jason
    Cragg, Andrew
    ANNALS OF VASCULAR SURGERY, 2014, 28 (04) : 808 - 815
  • [50] Aortic-neck dilation after endovascular abdominal aortic aneurysm repair (EVAR): can it be predicted?
    Iezzi, R.
    Santoro, M.
    Di Natale, G.
    Pirro, F.
    Dattesi, R.
    Nestola, M.
    Snider, F.
    Bonomo, L.
    RADIOLOGIA MEDICA, 2012, 117 (05): : 804 - 814