Influence of aortic neck characteristics on successful aortic wall penetration of EndoAnchors in therapeutic use during endovascular aneurysm repair

被引:24
|
作者
Goudeketting, Seline R. [1 ,2 ]
van Noort, Kim [1 ,2 ]
Ouriel, Kenneth [3 ]
Jordan, William D., Jr. [4 ]
Panneton, Jean M. [5 ]
Slump, Cornelis H. [2 ]
de Vries, Jean-Paul P. M. [1 ]
机构
[1] St Antonius Hosp, Dept Vasc Surg, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[2] Univ Twente, Fac Sci & Technol, Dept Tech Med, Enschede, Netherlands
[3] Syntactx, New York, NY USA
[4] Emory Univ, Sch Med, Dept Vasc Surg, Atlanta, GA USA
[5] Eastern Virginia Med Sch, Div Vasc Surg, Norfolk, VA 23501 USA
关键词
EndoAnchor; Endovascular aneurysm repair; Abdominal aortic aneurysm; Type IA endoleak; Aneurysm neck; ENDOGRAFT FIXATION; IA ENDOLEAK; ANATOMY; HOSTILE; EVAR; PLACEMENT; MIGRATION;
D O I
10.1016/j.jvs.2018.01.039
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study sought to quantify EndoAnchor (Medtronic Vascular, Santa Rosa, Calif) penetration into the aortic wall in patients undergoing endovascular abdominal aortic aneurysm repair and to assess predictors of successful penetration and its relationship to postprocedural type IA endoleak. Methods: A subset of patients from the Aneurysm Treatment Using the Heli-FX Aortic Securement System Global Registry (ANCHOR) were included if they met the following criteria: the indication for EndoAnchor use was to treat a type IA endoleak, and postprocedure contrast-enhanced computed tomography (CT) scans of sufficient quality were available for core laboratory review. Patients undergoing implantation of cuffs or stents during the EndoAnchor implantation procedure were excluded. Baseline anatomic characteristics were recorded. The cohort was divided into patients with and without persistent type IA endoleaks at the first postoperative CT scan. Penetration of each EndoAnchor measured on this CT scan was defined as good penetration when the EndoAnchor penetrated >= 2 mm into the aortic wall, borderline penetration when EndoAnchor penetration was <2mmor a gap remained between the endograft and aortic wall, or no penetration when the EndoAnchor did not penetrate into the aortic wall. Differences between the groups were analyzed with the Mann-Whitney U test or Fisher exact test. Multivariate analyses were performed to identify independent predictors of EndoAnchor penetration, and procedural success was defined by absence of type IA endoleak. Results: Eighty-six patients of the primary (n = 61 [71%]) and revision (n = 25 [29%]) arms of the ANCHOR registry were included. There were 53 (62%) without and 33 (38%) with persistent type IA endoleaks on the first postprocedural CT scan. The median number of EndoAnchors with good penetration was significantly greater in the cohort without endoleaks, 4 (interquartile range, 3-5) vs 3 (interquartile range, 1.5-4), respectively (P = .002). A multivariate model for EndoAnchor penetration identified use of a Medtronic Endurant endograft as a factor associated with good penetration (P = .001), whereas poor penetration was associated with a larger aortic neck diameter 10 mm distal to the lowest renal artery (P < .001) and greater proximal neck calcium thickness (P = .004). EndoAnchor penetration was the only variable that attained significance (P < .001) in the multivariate model for successful treatment of a type IA endoleak. Conclusions: Adequate EndoAnchor penetration into the aortic wall is less likely when the aortic neck diameter is large or when the neck contains significant mural calcium. No penetration of the EndoAnchor was the only factor predictive of postprocedural type IA endoleak. This study stresses the importance of careful selection of patients based on preoperative assessment of the infrarenal neck on CT angiography and emphasizes careful deployment of EndoAnchors into the aortic wall to improve successful treatment of type IA endoleaks.
引用
收藏
页码:1007 / 1016
页数:10
相关论文
共 50 条
  • [31] Endograft apposition and infrarenal neck enlargement after endovascular aortic aneurysm repair
    Van der Riet, Claire
    De Rooy, Philippe M.
    Tielliu, Ignace F.
    Kropman, Rogier H.
    Wille, Jan
    Narlawar, Ranjeet
    Elzefzaf, Nada Y.
    Antoniou, George A.
    De Vries, Jean-Paul
    Schuurmann, Richte C.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2021, 62 (06) : 600 - 608
  • [32] Endovascular aneurysm repair in short and angulated aortic aneurysmal neck: A retrospective case series of single centre experience
    Tran Quyet Tien
    Ho Tat Bang
    Nguyen Van Quang
    INTERNATIONAL JOURNAL OF SURGERY OPEN, 2020, 27 : 94 - 97
  • [33] Fenestrated endovascular aortic aneurysm repair promotes positive infrarenal neck remodeling and greater sac shrinkage compared with endovascular aortic aneurysm repair
    Teter, Katherine
    Li, Chong
    Ferreira, Luis M.
    Ferrer, Miguel
    Rockman, Caron
    Jacobowitz, Glenn
    Cayne, Neal
    Garg, Karan
    Maldonado, Thomas S.
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (02) : 344 - +
  • [34] Use of Chimney Technique Does Not Improve the Outcome of Endovascular Aneurysm Repair in Patients With a Hyperangulated and Short Proximal Aortic Neck
    Oezdemir-van Brunschot, Denise Michelle Danielle
    Torsello, Giovanni Battista
    Bernardini, Giulia
    Litterscheid, Sarah
    Torsello, Giovanni Federico
    Beropoulis, Efthymios
    JOURNAL OF ENDOVASCULAR THERAPY, 2022, 29 (03) : 361 - 369
  • [35] Editor's Choice - Influence of Proximal Aortic Neck Diameter on Durability of Aneurysm Sealing and Overall Survival in Patients Undergoing Endovascular Aneurysm Repair. Real World Data from the Gore Global Registry for Endovascular Aortic Treatment (GREAT)
    Howard, Dominic P. J.
    Marron, Conor D.
    Sideso, Ediri
    Puckridge, Phillip J.
    Verhoeven, Eric L. G.
    Spark, James, I
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 56 (02) : 189 - 199
  • [36] A new method for precise determination of endograft position and apposition in the aortic neck after endovascular aortic aneurysm repair
    Van Noort, Kim
    Schuurmann, Richte C. L.
    Slump, Cornelis H.
    Vos, Jan A.
    De Vries, Jean-Paul P. M.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 57 (05) : 737 - 746
  • [37] A Retrospective Review of Palmaz Stenting of the Aortic Neck for Endovascular Aneurysm Repair
    Farley, Steven Michael
    Rigberg, David
    Jimenez, Juan Carlos
    Moore, Wesley
    Quinones-Baldrich, William
    ANNALS OF VASCULAR SURGERY, 2011, 25 (06) : 735 - 739
  • [38] The Correlation of Aortic Neck Angle and Length in Abdominal Aortic Aneurysm with Severe Neck Angulation for Prediction of Intraoperative Neck Complications and Postoperative Outcomes after Endovascular Aneurysm Repair
    Chinsakchai, Khamin
    Sirivech, Thana
    Moll, Frans L.
    Tongsai, Sasima
    Hongku, Kiattisak
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [39] Influence of abdominal aortic aneurysm size on the feasibility of endovascular repair
    Armon, MP
    Yusuf, SW
    Whitaker, SC
    Gregson, RHS
    Wenham, PW
    Hopkinson, BR
    JOURNAL OF ENDOVASCULAR SURGERY, 1997, 4 (03): : 279 - 283
  • [40] Endograft platform does not influence aortic neck dilatation after infrarenal endovascular aneurysm repair with primary endostapling
    Chaudhuri, Arindam
    Badawy, Ayman
    VASCULAR, 2021, 29 (03) : 315 - 322