Influence of aortic neck characteristics on successful aortic wall penetration of EndoAnchors in therapeutic use during endovascular aneurysm repair

被引:24
|
作者
Goudeketting, Seline R. [1 ,2 ]
van Noort, Kim [1 ,2 ]
Ouriel, Kenneth [3 ]
Jordan, William D., Jr. [4 ]
Panneton, Jean M. [5 ]
Slump, Cornelis H. [2 ]
de Vries, Jean-Paul P. M. [1 ]
机构
[1] St Antonius Hosp, Dept Vasc Surg, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[2] Univ Twente, Fac Sci & Technol, Dept Tech Med, Enschede, Netherlands
[3] Syntactx, New York, NY USA
[4] Emory Univ, Sch Med, Dept Vasc Surg, Atlanta, GA USA
[5] Eastern Virginia Med Sch, Div Vasc Surg, Norfolk, VA 23501 USA
关键词
EndoAnchor; Endovascular aneurysm repair; Abdominal aortic aneurysm; Type IA endoleak; Aneurysm neck; ENDOGRAFT FIXATION; IA ENDOLEAK; ANATOMY; HOSTILE; EVAR; PLACEMENT; MIGRATION;
D O I
10.1016/j.jvs.2018.01.039
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study sought to quantify EndoAnchor (Medtronic Vascular, Santa Rosa, Calif) penetration into the aortic wall in patients undergoing endovascular abdominal aortic aneurysm repair and to assess predictors of successful penetration and its relationship to postprocedural type IA endoleak. Methods: A subset of patients from the Aneurysm Treatment Using the Heli-FX Aortic Securement System Global Registry (ANCHOR) were included if they met the following criteria: the indication for EndoAnchor use was to treat a type IA endoleak, and postprocedure contrast-enhanced computed tomography (CT) scans of sufficient quality were available for core laboratory review. Patients undergoing implantation of cuffs or stents during the EndoAnchor implantation procedure were excluded. Baseline anatomic characteristics were recorded. The cohort was divided into patients with and without persistent type IA endoleaks at the first postoperative CT scan. Penetration of each EndoAnchor measured on this CT scan was defined as good penetration when the EndoAnchor penetrated >= 2 mm into the aortic wall, borderline penetration when EndoAnchor penetration was <2mmor a gap remained between the endograft and aortic wall, or no penetration when the EndoAnchor did not penetrate into the aortic wall. Differences between the groups were analyzed with the Mann-Whitney U test or Fisher exact test. Multivariate analyses were performed to identify independent predictors of EndoAnchor penetration, and procedural success was defined by absence of type IA endoleak. Results: Eighty-six patients of the primary (n = 61 [71%]) and revision (n = 25 [29%]) arms of the ANCHOR registry were included. There were 53 (62%) without and 33 (38%) with persistent type IA endoleaks on the first postprocedural CT scan. The median number of EndoAnchors with good penetration was significantly greater in the cohort without endoleaks, 4 (interquartile range, 3-5) vs 3 (interquartile range, 1.5-4), respectively (P = .002). A multivariate model for EndoAnchor penetration identified use of a Medtronic Endurant endograft as a factor associated with good penetration (P = .001), whereas poor penetration was associated with a larger aortic neck diameter 10 mm distal to the lowest renal artery (P < .001) and greater proximal neck calcium thickness (P = .004). EndoAnchor penetration was the only variable that attained significance (P < .001) in the multivariate model for successful treatment of a type IA endoleak. Conclusions: Adequate EndoAnchor penetration into the aortic wall is less likely when the aortic neck diameter is large or when the neck contains significant mural calcium. No penetration of the EndoAnchor was the only factor predictive of postprocedural type IA endoleak. This study stresses the importance of careful selection of patients based on preoperative assessment of the infrarenal neck on CT angiography and emphasizes careful deployment of EndoAnchors into the aortic wall to improve successful treatment of type IA endoleaks.
引用
收藏
页码:1007 / 1016
页数:10
相关论文
共 50 条
  • [21] Influence of infrarenal neck length on outcome of endovascular abdominal aortic aneurysm repair
    Leurs, Lina J.
    Kievit, Jur
    Dagnelie, Pieter C.
    Nelemans, Patty J.
    Buth, Jacob
    JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (05) : 640 - 648
  • [22] Endovascular repair with chimney technique of abdominal aortic aneurysm with hostile aortic neck
    Kim, Jang Yong
    Park, Jae Young
    Cho, Soon Gu
    Jin, Chan Ik
    Lee, W. Anthony
    Jeon, Yong Sun
    Hong, Kee Chun
    VASCULAR, 2013, 21 (05) : 323 - 329
  • [23] Residual Infrarenal Aortic Neck following Endovascular and Open Aneurysm Repair
    De Bruin, J. L.
    de Jong, S.
    Pol, J.
    van der Jagt, M.
    Prinssen, M.
    Blankensteijn, J. D.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (04) : 415 - 418
  • [24] Suitability of the Aortic Neck Anatomy for Endovascular Aneurysm Repair in Korean Patients with Abdominal Aortic Aneurysm
    Hwang, Deokbi
    Kim, Jihye
    Kim, Hyung-Kee
    Huh, Seung
    VASCULAR SPECIALIST INTERNATIONAL, 2020, 36 (02) : 71 - 81
  • [25] The influence of gender and aortic aneurysm size on eligibility for endovascular abdominal aortic aneurysm repair
    Sweet, Matthew P.
    Fillinger, Mark F.
    Morrison, Tina M.
    Abel, Dorothy
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (04) : 931 - 937
  • [26] Selective aneurysmal sac neck-targeted embolization during endovascular repair of abdominal aortic aneurysm with hostile neck anatomy
    Zhang, Lifeng
    Tang, Yongjiang
    Wang, Jiantao
    Liu, Xianjun
    Liu, Yang
    Zeng, Wei
    He, Chunshui
    JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [27] Analysis of the position of EndoAnchor implants in therapeutic use during endovascular aneurysm repair
    Goudeketting, Seline R.
    van Noort, Kim
    Vermeulen, Jenske J. M.
    Ouriel, Kenneth
    Jordan, William D., Jr.
    Panneton, Jean M.
    Slump, Cornelis H.
    de Vries, Jean-Paul P. M.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : 1726 - 1735
  • [28] The association between device instructions for use adherence and outcomes after elective endovascular aortic abdominal aneurysm repair
    De Guerre, Livia E. V. M.
    O'Donnell, Thomas F. X.
    Varkevisser, Rens R. B.
    Swerdlow, Nicholas J.
    Li, Chun
    Dansey, Kirsten
    van Herwaarden, Joost A.
    Schermerhorn, Marc L.
    Patel, Virendra, I
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (03) : 690 - +
  • [29] Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair
    Ishibashi, Hiroyuki
    Ishiguchi, Tsuneo
    Ohta, Takashi
    Sugimoto, Ikuo
    Iwata, Hirohide
    Yamada, Tetsuya
    Tadakoshi, Masao
    Hida, Noriyuki
    Orimoto, Yuki
    Kamei, Seiji
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (05) : 939 - 942
  • [30] Classification of gutter type in parallel stenting during endovascular aortic aneurysm repair
    Overeem, Simon P.
    Boersen, Johannes T.
    Schuurmann, Richte C. L.
    Jebbink, Erik Groot
    Slump, Cornelis H.
    Reijnen, Michel M. P. J.
    de Vries, Jean-Paul P. M.