Influence of aortic neck characteristics on successful aortic wall penetration of EndoAnchors in therapeutic use during endovascular aneurysm repair

被引:24
|
作者
Goudeketting, Seline R. [1 ,2 ]
van Noort, Kim [1 ,2 ]
Ouriel, Kenneth [3 ]
Jordan, William D., Jr. [4 ]
Panneton, Jean M. [5 ]
Slump, Cornelis H. [2 ]
de Vries, Jean-Paul P. M. [1 ]
机构
[1] St Antonius Hosp, Dept Vasc Surg, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[2] Univ Twente, Fac Sci & Technol, Dept Tech Med, Enschede, Netherlands
[3] Syntactx, New York, NY USA
[4] Emory Univ, Sch Med, Dept Vasc Surg, Atlanta, GA USA
[5] Eastern Virginia Med Sch, Div Vasc Surg, Norfolk, VA 23501 USA
关键词
EndoAnchor; Endovascular aneurysm repair; Abdominal aortic aneurysm; Type IA endoleak; Aneurysm neck; ENDOGRAFT FIXATION; IA ENDOLEAK; ANATOMY; HOSTILE; EVAR; PLACEMENT; MIGRATION;
D O I
10.1016/j.jvs.2018.01.039
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study sought to quantify EndoAnchor (Medtronic Vascular, Santa Rosa, Calif) penetration into the aortic wall in patients undergoing endovascular abdominal aortic aneurysm repair and to assess predictors of successful penetration and its relationship to postprocedural type IA endoleak. Methods: A subset of patients from the Aneurysm Treatment Using the Heli-FX Aortic Securement System Global Registry (ANCHOR) were included if they met the following criteria: the indication for EndoAnchor use was to treat a type IA endoleak, and postprocedure contrast-enhanced computed tomography (CT) scans of sufficient quality were available for core laboratory review. Patients undergoing implantation of cuffs or stents during the EndoAnchor implantation procedure were excluded. Baseline anatomic characteristics were recorded. The cohort was divided into patients with and without persistent type IA endoleaks at the first postoperative CT scan. Penetration of each EndoAnchor measured on this CT scan was defined as good penetration when the EndoAnchor penetrated >= 2 mm into the aortic wall, borderline penetration when EndoAnchor penetration was <2mmor a gap remained between the endograft and aortic wall, or no penetration when the EndoAnchor did not penetrate into the aortic wall. Differences between the groups were analyzed with the Mann-Whitney U test or Fisher exact test. Multivariate analyses were performed to identify independent predictors of EndoAnchor penetration, and procedural success was defined by absence of type IA endoleak. Results: Eighty-six patients of the primary (n = 61 [71%]) and revision (n = 25 [29%]) arms of the ANCHOR registry were included. There were 53 (62%) without and 33 (38%) with persistent type IA endoleaks on the first postprocedural CT scan. The median number of EndoAnchors with good penetration was significantly greater in the cohort without endoleaks, 4 (interquartile range, 3-5) vs 3 (interquartile range, 1.5-4), respectively (P = .002). A multivariate model for EndoAnchor penetration identified use of a Medtronic Endurant endograft as a factor associated with good penetration (P = .001), whereas poor penetration was associated with a larger aortic neck diameter 10 mm distal to the lowest renal artery (P < .001) and greater proximal neck calcium thickness (P = .004). EndoAnchor penetration was the only variable that attained significance (P < .001) in the multivariate model for successful treatment of a type IA endoleak. Conclusions: Adequate EndoAnchor penetration into the aortic wall is less likely when the aortic neck diameter is large or when the neck contains significant mural calcium. No penetration of the EndoAnchor was the only factor predictive of postprocedural type IA endoleak. This study stresses the importance of careful selection of patients based on preoperative assessment of the infrarenal neck on CT angiography and emphasizes careful deployment of EndoAnchors into the aortic wall to improve successful treatment of type IA endoleaks.
引用
收藏
页码:1007 / 1016
页数:10
相关论文
共 50 条
  • [1] Systematic Review of the Use of Endoanchors in Endovascular Aortic Aneurysm Repair
    Qamhawi, Zahi
    Barge, Thomas F.
    Makris, Gregory C.
    Patel, Rafiuddin
    Wigham, Andrew
    Anthony, Suzie
    Uberoi, Raman
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 59 (05) : 748 - 756
  • [2] Use of EndoAnchors during index endovascular aortic aneurysm repair in patients with hostile proximal aortic neck anatomy
    Sivak, Jozef
    Suchac, Martin
    Daxner, Maros
    Kmetkova, Katarina
    Sykora, Jan
    Zapletalova, Jana
    Zelenak, Kamil
    Simkova, Iveta
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2024, 125 (06): : 347 - 353
  • [3] Predictors of early aortic neck dilatation after endovascular aneurysm repair with EndoAnchors
    Tassiopoulos, Apostolos K.
    Monastiriotis, Spyridon
    Jordan, William D.
    Muhs, Bart E.
    Ouriel, Kenneth
    De Vries, Jean Paul
    JOURNAL OF VASCULAR SURGERY, 2017, 66 (01) : 45 - 52
  • [4] One-year results of the ANCHOR trial of EndoAnchors for the prevention and treatment of aortic neck complications after endovascular aneurysm repair
    Jordan, William D., Jr.
    Mehta, Manish
    Ouriel, Kenneth
    Arko, Frank R.
    Varnagy, David
    Joye, James
    Moore, William M., Jr.
    de Vries, Jean-Paul P. M.
    VASCULAR, 2016, 24 (02) : 177 - 186
  • [5] Endovascular Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy
    Stather, Philip W.
    Wild, John B.
    Sayers, Robert D.
    Bown, Matthew J.
    Choke, Edward
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (05) : 623 - 637
  • [6] The use of EndoAnchors in endovascular repair of abdominal aortic aneurysms with challenging proximal neck: Single-centre experience
    Giudice, Rocco
    Borghese, Ottavia
    Sbenaglia, Giorgio
    Coscarella, Carlo
    De Gregorio, Claudia
    Leopardi, Marco
    Pogany, Gabriele
    JRSM CARDIOVASCULAR DISEASE, 2019, 8
  • [7] Aortic Neck Angulations Decrease During and After Endovascular Aneurysm Repair
    van Keulen, Jasper W.
    Moll, Frans L.
    Arts, Jeroen
    Vonken, Evert-Jan P.
    van Herwaarden, Joost A.
    JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (05) : 594 - 598
  • [8] Prognostic significance of large diameter proximal aortic neck in endovascular aneurysm repair
    Antoniou, George A.
    Alfahad, Aws
    Antoniou, Stavros A.
    Badri, Hassan
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2020, 49 (03) : 215 - 224
  • [9] The incidence and effect of noncylindrical neck morphology on outcomes after endovascular aortic aneurysm repair in the Global Registry for Endovascular Aortic Treatment
    Shutze, William
    Suominen, Velipekka
    Jordan, William
    Cao, Piergiorgio
    Oweida, Steven
    Milner, Ross
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (06) : 1714 - 1724
  • [10] The impact of large proximal aortic neck on endovascular aneurysm repair outcomes
    Aytekin, Bahadnr
    Deniz, Gokay
    Cetinkaya, Ferit
    Mola, Serkan
    Tumer, Naim Boran
    Unal, Ertekin Utku
    Durukan, Ahmet Barns
    Iscan, Hakkn Zafer
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 31 (04): : 489 - 497