Fatigue Performance of a Lightweight Composite Bridge Deck with Open Ribs

被引:92
作者
Zhang, Shihong [1 ,2 ]
Shao, Xudong [2 ]
Cao, Junhui [2 ]
Cui, Jianfeng [3 ]
Hu, Jianhua [3 ]
Deng, Lu [2 ]
机构
[1] Henan Prov Commun Planning Survey & Design Inst C, Zhengzhou 450015, Peoples R China
[2] Hunan Univ, Key Lab Wind & Bridge Engn Hunan Prov, Changsha 410082, Hunan, Peoples R China
[3] Hunan Prov Commun Planning Survey & Design Inst, Changsha 410008, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Orthotropic steel deck (OSD); Open rib; Ultrahigh-performance concrete (UHPC); Lightweight composite deck (LWCD); Hot spot stress; Fatigue test; BEHAVIOR; JOINTS;
D O I
10.1061/(ASCE)BE.1943-5592.0000905
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An innovative lightweight composite deck (LWCD) is proposed for steel bridges to avoid premature fatigue cracking. The composite deck is composed of an open-ribbed orthotropic steel deck (OSD) and a thin ultrahigh-performance concrete (UHPC) layer. This study is based on a suspension steel bridge in China, namely, the Second Dongting Lake Bridge. The following investigations were performed: (1) preliminary finite-element analysis (FEA) was carried out to evaluate the vehicle-induced stress ranges (i.e., sigma = sigma(max) - sigma(min)) of six typical fatigue-prone details; (2) parameter analyses were performed to investigate the effects of the shape of cutouts and the thickness of the floor beams; and (3) two fatigue tests, one that used a full-scale LWCD panel and another that used a LWCD beam specimen, were conducted to reveal fatigue performance of the OSD and the stud shear connectors, respectively. Results of the preliminary FEA show that, with the contribution of the UHPC layer, the vehicle-induced stress ranges at some fatigue details of the LWCD, such as the rib-deck plate welded joints and the splice welds of the longitudinal ribs, were reduced to be less than their constant-amplitude fatigue limits, which indicates theoretically infinite fatigue lives of these details. The parameter analyses reveal that the apple-shaped cutout had relative good fatigue properties among the four cutout schemes and that the thickness of the floor beams is recommended to be 14-18 mm. According to the fatigue tests on the composite panel specimen and on the composite beam specimen, both the open-ribbed OSD and the stud shear connectors exhibited satisfactory fatigue endurances, which were much greater than 2 million cycles. The current theoretical and experimental investigations reveal that the proposed open-ribbed LWCD has favorable fatigue performances.
引用
收藏
页数:16
相关论文
共 32 条
[1]  
[Anonymous], THESIS
[2]  
[Anonymous], 19912 ECS EN
[3]  
[Anonymous], ANSYS 14 0 COMP SOFT
[4]  
[Anonymous], AB 6 14 COMP SOFT
[5]  
[Anonymous], 2008, RECOMMENDATIONS FATI
[6]  
[Anonymous], 2005, EN199319 ECS
[7]   Modelling and fatigue life assessment of orthotropic bridge deck details using FEM [J].
Aygul, Mustafa ;
Al-Emrani, Mohammad ;
Urushadze, Shota .
INTERNATIONAL JOURNAL OF FATIGUE, 2012, 40 :129-142
[8]  
Behloul M., 2005, P 7 INT S UT HIGH ST
[9]  
Bin Chen, 2014, CICTP 2014. Safe, Smart and Sustainable Multimodal Transportation Systems. 14th COTA International Conference of Transportation Professionals. Proceedings, P1051
[10]   Retrofit of an orthotropic steel deck with compact reinforced reactive powder concrete [J].
Cao, Junhui ;
Shao, Xudong ;
Zhang, Zhe ;
Zhao, Hua .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2016, 12 (03) :411-429