AC Breakdown and Trap Distribution Characteristics of Polypropylene Laminated Paper after Electrical Ageing

被引:2
作者
Ouyang, B. H. [1 ]
Yan, Z. M. [2 ]
Liu, Z. X. [1 ]
Yang, K. [2 ]
Wang, S. H. [2 ]
Li, J. Y. [2 ]
机构
[1] China Elect Power Res Inst, Wuhan 430074, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
来源
PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020) | 2020年
关键词
D O I
10.1109/ICD46958.2020.9341891
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The failures of polypropylene laminated paper (PPLP), the major insulation of high temperature superconducting (HTS) cables, are mainly rooted in the electrical ageing. In this paper, effects of electrical ageing on AC breakdown and trap distribution characteristics of PPLP are investigated. Electrical ageing under AC voltage of PPLP in liquid nitrogen is carried out. The breakdown performance and trap distribution of PPLP are characterized by AC breakdown and isothermal surface potential decay (ISPD) measurements. In addition, the aged samples are further analyzed by Fourier transform infrared (FTIR) spectroscopy and scanning electron microscope (SEM). Results demonstrate that the breakdown strength of PPLP decreases from 113.32 kV/mm to 92.36 kV/mm after ageing for 60 min under 30 kV. The energy level and trap density of deep trap calculated by ISPD results both decrease with ageing. FTIR and SEM indicate that the partial cellulose of insulating paper on the out-layer of PPLP is broken under the impact of high-energy electrons. As a result, the free volume of insulating paper is expanded, and the binding ability of cellulose molecular chains to charge carriers is weakened, which leads to the decrease of energy level and trap density of deep trap and further promotes the charge transportation. Therefore, a decreased breakdown strength of PPLP can be observed after electrical ageing. In conclusion, it is proposed that the destruction of molecular chain structure in the aged PPLP can lead the change of trap distribution, further resulting in the decline of breakdown strength.
引用
收藏
页码:134 / 137
页数:4
相关论文
共 50 条
[31]   Trap Distribution and Dielectric Breakdown of Isotactic Polypropylene/Propylene Based Elastomer With Improved Flexibility for DC Cable Insulation [J].
Gao, Yu ;
Li, Jing ;
Yuan, Yanqiu ;
Huang, Shihao ;
Du, Boxue .
IEEE ACCESS, 2018, 6 :58645-58661
[32]   Breakdown Characteristics of Oil Impregnated Insulation Paper with Different Ageing Condition under the Composite Electric Field [J].
Wang, Qian ;
Hao, Jian ;
Liu, Tuan ;
Fu, Jin ;
Wu, Gaolin .
APPLIED SCIENCE, MATERIALS SCIENCE AND INFORMATION TECHNOLOGIES IN INDUSTRY, 2014, 513-517 :328-331
[33]   PD inception characteristics of polypropylene laminated paper/liquid nitrogen composite insulation system under local heating [J].
Takahashi, T ;
Suzuki, H ;
Ichikawa, M ;
Okamoto, T .
2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, :365-368
[34]   Influence of bubble size and flow velocity on AC electrical breakdown characteristics of LN2 [J].
Kim, SH ;
Jeong, JM ;
Kim, YS ;
Kim, CO ;
Baek, SM .
CRYOGENICS, 2002, 42 (6-7) :411-414
[35]   Trap Distribution and Breakdown Characteristics of Direct-Fluorinated PI Film for DC-HTSFCL [J].
Xing, Yunqi ;
Yuan, Ruiyi ;
Li, Ang ;
Xiao, Meng ;
Zhang, Xueqiao ;
Wang, Yao .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
[36]   Effect of trap level density on breakdown strength and space charge distribution of polypropylene/low-density polyethylene composites [J].
Yan, Hong-Da ;
Zhang, Chong ;
Li, Wei-Kang ;
Zha, Jun-Wei .
POLYMER COMPOSITES, 2020, 41 (02) :780-787
[37]   DC Breakdown and Space Charge Characteristics of Mineral Oil Impregnated Thermally Upgraded Paper With Different Ageing Conditons [J].
Zou, Runhao ;
Hao, Jian ;
Liao, Ruijin .
2019 IEEE 20TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2019,
[38]   Breakdown Characteristics of Oil-Paper Insulation in UHVDC Converter Transformer Under AC/DC Voltage and Its Selection of Oil and Paper [J].
Liao, Ruijin ;
Shao, Shanfeng ;
Cheng, Li ;
Yang, Lijun ;
Zhao, Xuetong .
Dianwang Jishu/Power System Technology, 2018, 42 (02) :387-392
[39]   Analysis of Electrical Life Distribution Characteristics of AC Contactor Based on Performance Degradation [J].
Zheng, Shumei ;
Niu, Feng ;
Li, Kui ;
Huang, Shaopo ;
Liu, Zhengjun ;
Wu, Yi .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2018, 8 (09) :1604-1613
[40]   Relation between DC PDIV and DC BDV of Mass Impregnated Polypropylene Laminated Paper Considering the Thermal Aging Characteristics [J].
Kim, Ho-Seung ;
Oh, Dong-Hun ;
Kim, Yong-Rok ;
Lee, Bang-Wook .
2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, :369-372