AC Breakdown and Trap Distribution Characteristics of Polypropylene Laminated Paper after Electrical Ageing

被引:2
|
作者
Ouyang, B. H. [1 ]
Yan, Z. M. [2 ]
Liu, Z. X. [1 ]
Yang, K. [2 ]
Wang, S. H. [2 ]
Li, J. Y. [2 ]
机构
[1] China Elect Power Res Inst, Wuhan 430074, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
来源
PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020) | 2020年
关键词
D O I
10.1109/ICD46958.2020.9341891
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The failures of polypropylene laminated paper (PPLP), the major insulation of high temperature superconducting (HTS) cables, are mainly rooted in the electrical ageing. In this paper, effects of electrical ageing on AC breakdown and trap distribution characteristics of PPLP are investigated. Electrical ageing under AC voltage of PPLP in liquid nitrogen is carried out. The breakdown performance and trap distribution of PPLP are characterized by AC breakdown and isothermal surface potential decay (ISPD) measurements. In addition, the aged samples are further analyzed by Fourier transform infrared (FTIR) spectroscopy and scanning electron microscope (SEM). Results demonstrate that the breakdown strength of PPLP decreases from 113.32 kV/mm to 92.36 kV/mm after ageing for 60 min under 30 kV. The energy level and trap density of deep trap calculated by ISPD results both decrease with ageing. FTIR and SEM indicate that the partial cellulose of insulating paper on the out-layer of PPLP is broken under the impact of high-energy electrons. As a result, the free volume of insulating paper is expanded, and the binding ability of cellulose molecular chains to charge carriers is weakened, which leads to the decrease of energy level and trap density of deep trap and further promotes the charge transportation. Therefore, a decreased breakdown strength of PPLP can be observed after electrical ageing. In conclusion, it is proposed that the destruction of molecular chain structure in the aged PPLP can lead the change of trap distribution, further resulting in the decline of breakdown strength.
引用
收藏
页码:134 / 137
页数:4
相关论文
共 50 条
  • [1] Effects of Electrical Aging on AC Breakdown and Trap Distribution Characteristics of Polypropylene Laminated Papers in Liquid Nitrogen
    Li H.
    Fu S.
    Yan Z.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2020, 54 (02): : 103 - 110
  • [2] Impulse and ac partial discharge inception and breakdown characteristics of LN2/polypropylene laminated paper composite insulation system
    Okubo, H.
    Kojima, H.
    Endo, F.
    Sahara, K.
    Hayakawa, N.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (03) : 664 - 669
  • [3] Dielectric Breakdown Mechanism of Polypropylene Laminated Paper in Liquid Nitrogen
    Nagao, M.
    Kurimoto, M.
    Takahashi, R.
    Kawashima, T.
    Murakami, Y.
    Nishimura, T.
    Ashibe, Y.
    Masuda, T.
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 419 - 422
  • [4] Verification of the trap theory of polymer breakdown by electrical ageing in PP
    Wang, Xinsheng
    Tu, Demin
    Yang, Huizhong
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 1993, 27 (06): : 43 - 48
  • [5] Impulse and ac PD inception characteristics of LN2/polypropylene laminated paper composite insulation system
    Okubo, H
    Nagino, M
    Kojima, H
    Hayakawa, N
    Takahashi, T
    Yasuda, K
    ICDL: 2005 IEEE International Conference on Dielectric Liquids, 2005, : 429 - 432
  • [6] A Study on Insulation Characteristics of Laminated Polypropylene Paper for an HTS Cable
    Choi, J. -W.
    Cheon, H. -G.
    Choi, J. -H
    Kim, H. -J.
    Cho, J. -W.
    Kim, S. -H.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 1276 - 1279
  • [7] Trap distribution and direct current breakdown characteristics in polypropylene/Al2O3 nanodielectrics
    Ma Chao
    Min Dao-Min
    Li Sheng-Tao
    Zheng Xu
    Li Xi-Yu
    Min Chao
    Zhan Hai-Xia
    ACTA PHYSICA SINICA, 2017, 66 (06)
  • [8] Breakdown voltage of polypropylene laminated paper (PPLP) in plain samples and a full scale cable
    Worzyk, TB
    Bergkvist, M
    Nordberg, P
    Tornkvist, C
    IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 329 - 333
  • [9] AC Electrical Breakdown Characteristics of an Epoxy/Mica Composite
    Park, Jae-Jun
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2012, 13 (04) : 200 - 203
  • [10] Partial discharge inception and breakdown characteristics of LN2/polypropylene laminated paper composite insulation system for HTS cables
    Hayakawa, N
    Sahara, K
    Kojima, H
    Endo, F
    Okubo, H
    2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, : 345 - 348