RADIATION EXPOSURE TO PATIENTS AND MEDICAL STAFF IN HEPATIC CHEMOEMBOLISATION INTERVENTIONAL PROCEDURES IN RECIFE, BRAZIL

被引:11
作者
Khoury, H. J. [1 ]
Garzon, W. J. [1 ]
Andrade, G. [2 ]
Lunelli, N. [1 ]
Kramer, R. [1 ]
de Barros, V. S. M. [1 ]
Huda, A. [3 ]
机构
[1] Univ Fed Pernambuco, Dept Nucl Energy, Recife, PE, Brazil
[2] IMIP Inst Med Dr Fernando Figueira, Recife, PE, Brazil
[3] Calif State Univ Fresno, Fresno, CA 93740 USA
关键词
RADIOLOGY; DOSIMETRY; SKIN;
D O I
10.1093/rpd/ncv075
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study was to evaluate patient and medical staff absorbed doses received from transarterial chemoembolisation of hepatocellular carcinoma, which is the most common primary liver tumour worldwide. The study was performed in three hospitals in Recife, capital of the state of Pernambuco, located in the Brazilian Northeastern region. Two are public hospitals (A and B), and one is private (C). For each procedure, the number of images, irradiation parameters (kV, mA and fluoroscopy time), the air kerma-area product (P-KA) and the cumulative air kerma (K-a,K-r) at the reference point were registered. The maximum skin dose (MSD) of the patient was estimated using radiochromic film. For the medical staff dosimetry, thermoluminescence dosemeters (TLD- 100) were attached next to the eyes, close to the thyroid (above the shielding), on the thorax under the apron, on the wrist and on the feet. The effective dose to the staff was estimated using the algorithm of von Boetticher. The results showed that the mean value of the total P-KA was 267.49, 403.83 and 479.74 Gy cm(2) for Hospitals A, B and C, respectively. With regard to the physicians, the average effective dose per procedure was 17 mu Sv, and the minimum and maximum values recorded were 1 and 41 mu Sy, respectively. The results showed that the feet received the highest doses followed by the hands and lens of the eye, since the physicians did not use leaded glasses and the equipment had no lead curtain.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 15 条
[1]  
American Association of Physicists in Medicine, 2001, 70 AAPM
[2]   Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels [J].
Antic, V. ;
Ciraj-Bjelac, O. ;
Rehani, M. ;
Aleksandric, S. ;
Arandjic, D. ;
Ostojic, M. .
RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) :276-284
[3]   Fluoroscopically Guided Interventional Procedures: A Review of Radiation Effects on Patients' Skin and Hair [J].
Balter, Stephen ;
Hopewell, John W. ;
Miller, Donald L. ;
Wagner, Louis K. ;
Zelefsky, Michael J. .
RADIOLOGY, 2010, 254 (02) :326-341
[4]   Interventional Radiology at a Single Institution over 9 Years: A Comprehensive Evaluation of Procedures and an Estimation of Collective Effective Dose [J].
Cornetto, Andrea Peruzzo ;
Pasquino, Massimo ;
Aimonetto, Stefania ;
Zenone, Flora ;
Catuzzo, Paola ;
Natrella, Massimiliano ;
Cristoferi, Massimo ;
Fanelli, Gianluca ;
Tofani, Santi ;
Meloni, Teodoro .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (12) :1665-1675
[5]  
European Commission, 2009, RAD PROTECTION, V160
[6]   Radiation exposure to patient and staff in hepatic chemoembolization:: Risk estimation of cancer and deterministic effects [J].
Hidajat, Nico ;
Wust, Peter ;
Felix, Roland ;
Schroeder, Ralf Juergen .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (05) :791-796
[7]  
International Atomic Energy Agency, 2007, IAEA TECHNICAL REPOR
[8]  
International Commission on Radiation Protection, 2007, ANN ICRP, V37
[9]  
International Commission on Radiological Protection, 2012, ANN ICRP, V41
[10]  
International Organization for Standardization, 1999, 40373 ISO, P4037