Three-level Inverter Fault Detection and Diagnosis Using Current-based Statistical Analysis

被引:3
作者
Baghli, M. [1 ,3 ]
Delpha, C. [2 ]
Diallo, D. [3 ,4 ]
Hallouche, A. [1 ]
机构
[1] Univ Djillali Liabes Sidi Bel Abbes, Lab IRECOM, Sidi Bel Abbes, Algeria
[2] Univ Paris Saclay, Univ Paris Sud, Cent Supelec, Lab Signaux & Syst,UMR 8506,CNRS, Paris, France
[3] Univ Paris Saclay, Univ Paris Sud, Cent Supelec, Lab GeePs,UMR 8507,CNRS,Sorbonne Univ, Paris, France
[4] Shanghai Maritime Univ, Dept Elect Automat, Shanghai, Peoples R China
来源
2018 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM-CHONGQING 2018) | 2018年
关键词
Three-level Neutral Point Clamped (NPC) inverter; Open Switch Fault (OSF); Intermittent faults effect; Fault Detection and Diagnosis (FDD); Cumulated Sum (CUSUM) analysis;
D O I
10.1109/PHM-Chongqing.2018.00123
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper is an incremental contribution to the monitoring of power converters. It deals with open switch Fault Detection and Diagnosis (FDD) in three-level Neutral Point Clamped (NPC) inverter for electrical drives. The approach is based on the already available phase current measurements. The fault features that are evaluated in the time domain are the first four statistical moments. Three methods of FDD have been evaluated. The first one analyses the time domain evolution of the fault features. With this method, the fault is detected with a probability of detection higher than 80% when the operating speed is higher than a tier of the nominal speed and the SNR = 40dB. However, the performances are degraded for low speed and for lower SNR. To improve the performances, we use the Cumulative Sum (CUSUM) algorithm designed for mean and variance variations. The optimality has been verified with the Kolmogorov-Smirnov test of the selected features Probability Density Functions (PDF). The fault is detected efficiently with both CUSUM indicators with almost 100% of detection probability even for the smallest considered fault duration of 100 square s.
引用
收藏
页码:686 / 691
页数:6
相关论文
共 15 条
[1]  
Basseville M, 1993, DETECTION ABRUPT CHA
[2]  
Blanke M, 2006, DIAGNOSIS FAULT TOLE, V2nd, P238
[3]  
Choudhury A., 2015, THESIS
[4]  
Delpha C, 2017, IEEE IND ELEC, P3828, DOI 10.1109/IECON.2017.8216653
[5]   Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives [J].
Errabelli, Rammohan Rao ;
Mutschler, Peter .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (02) :500-508
[6]  
Feng D. W., 2004, Canadian Conference on Electrical and Computer Engineering 2004 (IEEE Cat. No.04CH37513), P1471, DOI 10.1109/CCECE.2004.1349682
[7]  
Hanif A, 2014, CHIN CONTR CONF, P263, DOI 10.1109/ChiCC.2014.6896632
[8]  
Ikonen Mika., 2 LEVEL 3 LEVEL CONV
[9]  
Kim H.S., 2016, INT J APPL ENG RES, V11, P1494
[10]   Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's Vector approach [J].
Mendes, AMS ;
Cardoso, AJM .
IEMDC'99 - IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, PROCEEDINGS, 1999, :704-706