Application of novel praseodymium (III) PVC-membrane electrode for determination of Pr(III) ions in soil and sediment samples

被引:108
作者
Zamani, Hassan Ali [1 ]
Ganjali, Mohammad Reza [2 ,3 ]
Norouzi, Parviz [2 ,3 ]
Meghdadi, Soraia [4 ]
机构
[1] Islamic Azad Univ, Dept Appl Chem, Quchan Branch, Quchan, Iran
[2] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[3] Univ Tehran Med Sci, Endocrine & Metab Res Ctr, Tehran, Iran
[4] Isfahan Univ Technol, Dept Chem, Esfahan, Iran
关键词
potentiometry; sensors; ion-selective electrode; PVC membrane; N; Nbis(alpha-methylsalicylidene)diethylenetriamine;
D O I
10.1080/00032710801934957
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel Pr(III) ion-selective polyvinyl chloride (PVC) membrane sensor, based on N,N-bis(alpha-methylsalicylidene)diethylenetriamine (BMT) as a new ionophore, has been prepared and studied. The electrode showed good selectivity for Pr(III) ion with respect to most common cations, including alkali, alkaline earth, transition, and heavy metal ions. This electrode has a wide linear dynamic range from 1.0 x 10(-6) to 1.0 x 10(-2) M with a Nernstian slope of 19.8 +/- 0.2mV per decade and a low detection limit of 6.5 x 10(-7) M, in the pH range of 3.0-8.4, while response time was rapid (< 15 s). As far as applications of the recommended sensor are concerned, first it was employed as an indicator electrode in the potentiometric titration of Pr(III) ions with EDTA. Second, it was effectively applied to the determination of concentration of Pr(III) ions in soil and sediment samples, and validation with CRMs.
引用
收藏
页码:902 / 916
页数:15
相关论文
共 50 条
[1]   Cr(III) ion-selective membrane sensor based on 1,3-Diamino-2-hydroxypropane-N,N,N',N'- tetraacetic acid [J].
Abedi, Mohammad Reza ;
Zamani, Hassan Ali ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz .
SENSOR LETTERS, 2007, 5 (3-4) :516-521
[2]   Synthesis, characterization and X-ray crystal structures of [Ni(Me-sal)2dpt] and [Ni(Me-sal)dpt]Cl [J].
Amirnasr, M ;
Schenk, KJ ;
Meghdadi, S ;
Morshedi, M .
POLYHEDRON, 2006, 25 (03) :671-677
[3]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[4]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]   Determination of neodymium(III) ions in soil and sediment samples by a novel neodymium(III) sensor based on benzyl bisthiosemicarbazone [J].
Behmadi, Hossein ;
Zamani, Hassan Ali ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz .
ELECTROCHIMICA ACTA, 2007, 53 (04) :1870-1876
[6]   FLOTATION SPECTROPHOTOMETRIC DETERMINATION OF PRASEODYMIUM WITH 5,7-DICHLOROQUINOLIN-8-OL AND RHODAMINE 6G [J].
BHAGAVATHY, V ;
RAO, TP ;
DAMODARAN, AD .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :169-172
[7]   DIRECT DETERMINATION OF PRASEODYMIUM VALENCE IN PR2(COXFE1-X)14B [J].
CAPEHART, TW ;
MISHRA, RK ;
HERBST, JF .
JOURNAL OF APPLIED PHYSICS, 1992, 72 (02) :676-679
[8]   Construction of triiodide ion selective electrodes based on phenothiazine derivatives [J].
Farhadi, K ;
Maleki, R .
ANALYTICAL LETTERS, 2004, 37 (06) :1063-1078
[9]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[10]   A novel Holmium(III) membrane sensor based on N-(1-thien-2-ylmethylene)-1,3-benzothiazol-2-amine [J].
Ganjali, MR ;
Norouzi, P ;
Adib, M ;
Ahmadalinezhad, A .
ANALYTICAL LETTERS, 2006, 39 (06) :1075-1086