Soft tissue artifact distribution on lower limbs during treadmill gait: Influence of skin markers location on cluster design

被引:36
作者
Barre, Arnaud [1 ]
Jolles, Brigitte M. [2 ,3 ]
Theumann, Nicolas [3 ,4 ,5 ]
Aminian, Kamiar [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement LMAM, CH-1015 Lausanne, Switzerland
[2] CHU Vaudois, Dept Orthopaed Surg & Traumatol, Lausanne, Switzerland
[3] Univ Lausanne, Lausanne, Switzerland
[4] CHU Vaudois, Dept Radiol, Lausanne, Switzerland
[5] Clin Bois Cerf, Lausanne, Switzerland
基金
瑞士国家科学基金会;
关键词
Soft tissue artifact; Knee kinematics; Gait; Bi-plane fluoroscopy; Skin markers; TKA; IN-VIVO; JOINT KINEMATICS; KNEE KINEMATICS; MOVEMENT; WALKING; MOTION; THIGH; STEREOPHOTOGRAMMETRY; QUANTIFICATION; RECONSTRUCTION;
D O I
10.1016/j.jbiomech.2015.04.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Segment poses and joint kinematics estimated from skin markers are highly affected by soft tissue artifact (STA) and its rigid motion component (STA(RM)). While four marker-clusters could decrease the STA non-rigid motion during gait activity, other data, such as marker location or STA(RM) patterns, would be crucial to compensate for STA in clinical gait analysis. The present study proposed 1) to devise a comprehensive average map illustrating the spatial distribution of STA for the lower limb during treadmill gait and 2) to analyze STA(RM) from four marker-clusters assigned to areas extracted from spatial distribution. All experiments were realized using a stereophotogrammetric system to track the skin markers and a bi-plane fluoroscopic system to track the knee prosthesis. Computation of the spatial distribution of STA was realized on 19 subjects using 80 markers apposed on the lower limb. Three different areas were extracted from the distribution map of the thigh. The marker displacement reached a maximum of 24.9 mm and 153 mm in the proximal areas of thigh and shank, respectively. STA(RM) was larger on thigh than the shank with RMS error in cluster orientations between 1.2 degrees and 8.1 degrees. The translation RMS errors were also large (3.0 mm to 16.2 mm). No marker-cluster correctly compensated for STA(RM). However, the coefficient of multiple correlations exhibited excellent scores between skin and bone kinematics, as well as for STA(RM) between subjects. These correlations highlight dependencies between STA(RM) and the kinematic components. This study provides new insights for modeling STA(RM) for gait activity. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1965 / 1971
页数:7
相关论文
共 30 条
[1]   Accuracy of single-plane fluoroscopy in determining relative position and orientation of total knee replacement components [J].
Acker, Stacey ;
Li, Rebecca ;
Murray, Heather ;
John, Paul St. ;
Banks, Scott ;
Mu, Shang ;
Wyss, Urs ;
Deluzio, Kevin .
JOURNAL OF BIOMECHANICS, 2011, 44 (04) :784-787
[2]   Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity [J].
Akbarshahi, Massoud ;
Schache, Anthony G. ;
Fernandez, Justin W. ;
Baker, Richard ;
Banks, Scott ;
Pandy, Marcus G. .
JOURNAL OF BIOMECHANICS, 2010, 43 (07) :1292-1301
[3]   A linear soft tissue artefact model for human movement analysis: Proof of concept using in vivo data [J].
Andersen, Michael S. ;
Damsgaard, Michael ;
Rasmussen, John ;
Ramsey, Dan K. ;
Benoit, Daniel L. .
GAIT & POSTURE, 2012, 35 (04) :606-611
[4]   Modeling of the pliant surfaces of the thigh and leg during gait [J].
Ball, KA ;
Pierrynowski, MR .
LASER-TISSUE INTERACTION IX. PROCEEDINGS OF, 1998, 3254 :435-446
[5]   Soft Tissue Artifact Assessment During Treadmill Walking in Subjects With Total Knee Arthroplasty [J].
Barre, Arnaud ;
Thiran, Jean-Philippe ;
Jolles, Brigitte M. ;
Theumann, Nicolas ;
Aminian, Kamiar .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (11) :3131-3140
[6]   In vivo knee kinematics during gait reveals new rotation profiles and smaller translations [J].
Benoit, Daniel L. ;
Ramsey, Dan K. ;
Lamontagne, Mario ;
Xu, Lanyi ;
Wretenberg, Per ;
Renstrom, Per .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (454) :81-88
[7]   Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo [J].
Benoit, Daniel L. ;
Ramsey, Dan K. ;
Lamontagne, Mario ;
Xu, Lanyi ;
Wretenberg, Per ;
Renstrom, Per .
GAIT & POSTURE, 2006, 24 (02) :152-164
[8]   A hip joint kinematics driven model for the generation of realistic thigh soft tissue artefacts [J].
Camomilla, Valentina ;
Cereatti, Andrea ;
Cheze, Laurence ;
Cappozzo, Aurelio .
JOURNAL OF BIOMECHANICS, 2013, 46 (03) :625-630
[9]   Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[10]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100