Detection capability of tetracyclines analysed by a fluorescence technique:: comparison between bilinear and trilinear partial least squares models

被引:44
作者
García, I
Sarabia, LA
Ortiz, MC
机构
[1] Univ Burgos, Fac Sci, Dept Chem, Burgos 09001, Spain
[2] Univ Burgos, Fac Sci, Dept Math & Computat, Burgos 09001, Spain
关键词
capability of detection; fluorescence; tetracyclines; ISO; 11843; 2002/657/EC; trilinear PLS;
D O I
10.1016/j.aca.2003.09.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
According to the committee decision of 12 August 2002 (2002/657/EC) the capability of detection, CCbeta, must be set in all analytical methods not only at concentration levels close to zero but also at the maximum permitted limit (PL). In this work we describe a methodology which evaluates the capability of detection of a fluorescence technique with soft calibration models (bilinear and trilinear PLS) to determine tetracyclines (group B1 substances from annex 1 of Directive 96/23/EC). Its estimation is based on the generalisation of the procedure described in International Union of Pure and Applied Chemistry and in the ISO standard 11843 for univariate signals which evaluates the probabilities of false positive (alpha) and false negative (beta). The capability of detection, CCbeta, estimated from the second-order signal and the trilinear PLS model is 9.93 mug l(-1) of tetracycline, 17.75 mug l(-1) of oxytetracycline and 26.31 mug l(-1) of chlortetracycline, setting alpha and beta at 0.05. The capability of detection, CCbeta, determined around the PL (100 mug kg(-1) in milk and muscle) with the second-order signal is 109.4 mug l(-1) of tetracycline, 117.0 mug l(-1) of oxytetracycline and 124.9 mug l(-1) of chlortetracycline, setting alpha and beta at 0.05. The results were compared with those obtained with zero and first-order signals. The effect of the interferences on the capability of detection was also analysed as well as the number of standards used to build the models and their calibration range. When a tetracycline is quantified in presence of uncalibrated ones by means of the trilinear PLS model the errors oscillate between 14.70% for TC and 9.57% for OTC. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:193 / 203
页数:11
相关论文
共 40 条
[1]  
[Anonymous], 1987, BINDING CONSTANTS ME
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]  
[Anonymous], 1987, ROBUST REGRESSION OU
[4]   Second-order data by flow injection analysis with spectrophotometric diode-array detection and incorporated gel-filtration chromatographic column [J].
Bechmann, IE .
TALANTA, 1997, 44 (04) :585-591
[5]   Three-way multivariate calibration procedures applied to high-performance liquid chromatography coupled with fast-scanning fluorescence spectrometry detection.: Determination of polycyclic aromatic hydrocarbons in water samples [J].
Beltrán, JL ;
Guiteras, J ;
Ferrer, R .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1949-1955
[6]   Limit of detection estimator for second-order bilinear calibration [J].
Boqué, R ;
Ferré, J ;
Faber, NM ;
Rius, FX .
ANALYTICA CHIMICA ACTA, 2002, 451 (02) :313-321
[7]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[8]   Exploratory study of sugar production using fluorescence spectroscopy and multi-way analysis [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (02) :133-147
[9]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.0.CO
[10]  
2-C