A review of machines and devices to potentize homeopathic medicines

被引:5
作者
Basu, Abhirup [1 ]
Suresh, Akkihebbal Krishnamurthy [1 ,2 ]
Kane, Shantaram Govind [1 ]
Bellare, Jayesh Ramesh [1 ,2 ]
机构
[1] Indian Inst Technol, Dept Chem Engn, Adi Shankaracharya Marg, Bombay 400076, Maharashtra, India
[2] Indian Inst Technol, Dept Biosci & Bioengn, Adi Shankaracharya Marg, Bombay 400076, Maharashtra, India
关键词
Succussion; Dilution; Fluxion; Parameters; Performance assessment; WATER; HYPOTHESIS; CAVITATION; MEMORY;
D O I
10.1016/j.homp.2017.09.002
中图分类号
R [医药、卫生];
学科分类号
10 ;
摘要
Background: Potentization, consisting of serial dilution and succussion, is a key step in the manufacture of homeopathic medicines. Originally prescribed as a manual process, several attempts at mechanization have been published, patented and even commercialised in order to remove the human element and introduce reproducibility without drudgery. Various machines have been used overthe years to prepare homeopathic medicines. Although these machines follow the same principles, i.e. energetically mixing the medicines and diluting them significantly, their mode of operation is different from each other. Methods: This review paper surveys the main methods of preparation of homeopathic medicines. The main machines discussed are: Boericke's potentizer, Tyler Kent's instrument, John Alphonse's machine and the fluxion potentizer, which were used in the past, as well as more recent potentizers like arm-and-weight instruments, the K-Tronic potentizer and Quinn's machine. We review the construction and operating principle of each of these machines, along with their advantages and limitations. A scheme for relative performance assessment of these machines is proposed based on the parameters mechanical efficiency, physico-chemical efficiency, turbulence generation, energy dissipation, and accuracy of dilution. Results: Quinn's machine and the arm-and-weight potentizer perform well for generating turbulence due to high impaction forces, while John Alphonse's machine is much more accurate in diluting the homeopathic medicines at every step. Conclusions: Both the commercial potentizers, Quinn's machine and the K-Tronic potentizer, are completely automated and therefore reduce the manual labour and variation in succussive forces during each step, which may produce uniformity in physicochemical changes within the resulting homeopathic medicines.
引用
收藏
页码:240 / 249
页数:10
相关论文
共 36 条
[1]  
Alphonse J., Patent No. [4,911,897, 4911897]
[2]  
Anagnostatos G., 1994, ULTRA HIGH DILUTION, P121
[3]   The silica hypothesis for homeopathy: physical chemistry [J].
Anick, David J. ;
Ives, John A. .
HOMEOPATHY, 2007, 96 (03) :189-195
[4]  
[Anonymous], 1870, BRIT HOM PHARM
[5]  
[Anonymous], 1796, PRAKTISCHEN ARZNEIKU
[6]   Impact comminution of solids due to local kinetic energy of high shear strain rate: I. Continuum theory and turbulence analogy [J].
Bazant, Zdenek P. ;
Caner, Ferhun C. .
JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 2014, 64 :223-235
[7]  
Boericke W., 2002, Pocket Manual of Homoeopathic Materia Medica And Repertory And A Chapter on Rare and Uncommon Remedies
[8]   The memory of water: an overview [J].
Chaplin, Martin F. .
HOMEOPATHY, 2007, 96 (03) :143-150
[9]   Why Extreme Dilutions Reach Non-zero Asymptotes: A Nanoparticulate Hypothesis Based on Froth Flotation [J].
Chikramane, Prashant S. ;
Kalita, Dhrubajyoti ;
Suresh, Akkihebbal K. ;
Kane, Shantaram G. ;
Bellare, Jayesh R. .
LANGMUIR, 2012, 28 (45) :15864-15875
[10]   Extreme homeopathic dilutions retain starting materials: A nanoparticulate perspective [J].
Chikramane, Prashant Satish ;
Suresh, Akkihebbal K. ;
Bellare, Jayesh Ramesh ;
Kane, Shantaram Govind .
HOMEOPATHY, 2010, 99 (04) :231-242