Performance of concrete columns longitudinally reinforced with steel and GFRP bars and confined with GFRP spirals and cross ties under reversed cyclic loading

被引:22
作者
Prajapati, Girish Narayan [1 ]
Farghaly, Ahmed Sabry [1 ]
Benmokrane, Brahim [1 ]
机构
[1] Univ Sherbrooke, Dept Civil Engn, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
GFRP bars; GFRP spirals; Steel bars; Hybrid reinforcement; Concrete column; Seismic load; Drift; Ductility index; Hysteretic response; Energy dissipation; Design codes; FLEXURAL BEHAVIOR; CAPACITY; DESIGN; MODEL;
D O I
10.1016/j.engstruct.2022.114863
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports the comparative results of an experimental study performed on concrete columns reinforced entirely with glass fiber-reinforced polymer (GFRP) bars and with hybrid reinforcement (longitudinal steel bars and transverse GFRP spirals and cross ties) subjected to quasi-static cycling loading. Four full-scale bridge columns were constructed with longitudinal steel bars and confined with GFRP spirals and cross ties (hybrid-reinforced concrete columns). Four other columns were constructed solely with GFRP reinforcement (GFRP-reinforced concrete columns). The bridge columns had a cross section of 400 x 400 mm with a total height of 1850 mm. The columns were tested to failure under combined constant compressive axial load and quasi-static reversed lateral loading. The columns were investigated in terms of longitudinal bar type, longitudinal reinforcement ratio, and transverse reinforcement ratio. The results show that the longitudinal reinforcement type significantly affected column performance in terms of seismic parameters such as ductility and energy dissipation. The hybrid-reinforced concrete columns exhibited superior ductility and dissipated more energy than the GFRP-reinforced concrete columns. Furthermore, the GFRP-reinforced concrete columns experienced more gradual failure than the hybrid-reinforced concrete columns. Appropriately confined hybrid-reinforced concrete columns attained acceptable drift levels that meet the recommendations in most design codes. The transverse reinforcement ratio and longitudinal reinforcement ratio patently influenced column behavior. The lower elastic modulus of the GFRP bars compared to that of the steel bars had an impact on the theoretical lateral load capacity of the concrete columns.
引用
收藏
页数:17
相关论文
共 57 条
[1]   Evaluation of deflection in concrete members reinforced with fibre reinforced polymer (FRP) bars [J].
Abdalla, HA .
COMPOSITE STRUCTURES, 2002, 56 (01) :63-71
[2]   Strength of Bridge High-Strength Concrete Slender Compression Members Reinforced with GFRP Bars and Spirals: Experiments and Second-Order Analysis [J].
Abdelazim, Waseem ;
Mohamed, Hamdy M. ;
Benmokrane, Brahim ;
Nolan, Steven .
JOURNAL OF BRIDGE ENGINEERING, 2020, 25 (09)
[3]   Compressive Behaviour of Glass Fiber-Reinforced Polymer (GFRP) Reinforced Concrete Columns [J].
Abed, Farid ;
El Refai, Ahmed ;
ElMesalami, Nouran .
10TH INTERNATIONAL CONFERENCE ON FRP COMPOSITES IN CIVIL ENGINEERING (CICE 2020/2021), 2022, 198 :851-858
[4]  
ACI (American Concrete Institute), 2013, 3742R13 ACI
[5]   Axial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals [J].
Afifi, Mohammad Z. ;
Mohamed, Hamdy M. ;
Benmokrane, Brahim .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (01)
[6]   Seismic Performance of GFRP-Reinforced Concrete Rectangular Columns [J].
Ali, Mahmoud A. ;
El-Salakawy, Ehab .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (03)
[7]  
Alsayed S.H., 1999, Proc., Fourth Int. Symp. FRP Reinforcement for Reinf. Conc. Struct., P103, DOI DOI 10.14359/5614
[8]   Performance of glass fiber reinforced plastic bars as a reinforcing material for concrete structures [J].
Alsayed, SH ;
Al-Salloum, YA ;
Almusallam, TH .
COMPOSITES PART B-ENGINEERING, 2000, 31 (6-7) :555-567
[9]  
American Concrete Institute (ACI) Commitee 440, 2015, GUID DES CONSTR CONC
[10]  
[Anonymous], 2014, Design of Concrete Structures. CSA Standard A23.3-14