CT Nonuniform Attenuation and TEW Scatter Corrections in Brain Tc-99m ECD SPECT

被引:9
作者
Farid, Karim [1 ]
Habert, Marie-Odile [2 ,3 ]
Martineau, Antoine [4 ]
Caillat-Vigneron, Nadine [1 ,5 ]
Sibon, Igor [6 ,7 ,8 ]
机构
[1] Hop Hotel Dieu, AP HP, Nucl Med Serv, F-75181 Paris, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Nucl Med Serv, F-75634 Paris, France
[3] Univ Paris 06, INSERM, UMR S 678, Paris, France
[4] St Louis Hosp, Dept Nucl Med, Paris, France
[5] Univ Paris 05, Paris, France
[6] Univ Bordeaux 2, F-33076 Bordeaux, France
[7] Univ Hosp Bordeaux, Bordeaux, France
[8] CNRS, UMR 5231, Bordeaux, France
关键词
Tc-99m ECD SPECT/CT; attenuation correction; Alzheimer disease; cerebral blood flow; CEREBRAL-BLOOD-FLOW; COMPUTED-TOMOGRAPHY; DISTRIBUTIONS; QUANTIFICATION; COMPENSATION; TRANSMISSION; VOLUNTEERS;
D O I
10.1097/RLU.0b013e318217544c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Perfusion brain single photon emission computed tomography (SPECT) is currently used to evaluate patients with cognitive impairments. Although widely available, it has been reported to be significantly less sensitive than F-18 FDG positron emission tomography. Optimization of SPECT parameters using nonuniform attenuation correction (NUAC) and scatter correction (SC) might improve the accuracy of the method. This study assessed the effect of x-ray CT-based NUAC and triple-energy window (TEW-SC) on brain SPECT compared with Chang-uniform (UAC). A total of 31 patients with memory complaints underwent Tc-99m ECD SPECT/CT. CT-NUAC + TEW-SC and Chang-UAC were applied and compared. The images were spatially normalized to a default SPECT template supplied with Statistical Parametric Mapping software (SPM2). A paired t test image was then reconstructed. Regional cerebral blood flow measurements were apparently reduced in the frontal white-matter and in the frontotemporal cortex when CT-NUAC + TEW-SC were used. These findings need to be considered when interpreting Tc-99m ECD SPECT after applying CT-AC + TEW-SC. Further prospective studies with clinical correlations are needed.
引用
收藏
页码:665 / 668
页数:4
相关论文
共 50 条
[41]   Utility of Tc-99m MDP bone SPECT in evaluation of osseous involvement in craniofacial malignancies [J].
Saeed, Shabana ;
ul Haq, Saif ;
Sohaib, Muhammad ;
Khan, Ali Nawaz .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (11) :1815-1819
[42]   VIRAL ENCEPHALITIS IN CHILDREN - DETECTION WITH TC-99M HMPAO BRAIN SINGLE-PHOTON EMISSION CT AND ITS VALUE IN PREDICTION OF OUTCOME [J].
KAO, CH ;
WANG, SJ ;
MAK, SC ;
SHIAN, WJ ;
CHI, CS .
AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (07) :1369-1373
[43]   Effect of attenuation correction on normal Tc-99m-MIBI myocardial perfusion scintigrams acquired with a hybrid SPECT/CT camera [J].
Plachcinska, Anna ;
Siennicki, Jakub ;
Kovacevic-Kusmierek, Katarzyna ;
Bienkiewicz, Malgorzata ;
Kusmierek, Jacek .
NUCLEAR MEDICINE REVIEW, 2008, 11 (02) :59-66
[44]   Implementation of a Tc-99m and Ce-139 scanning line source for attenuation correction in SPECT using a dual opposing detector scintillation camera [J].
du Raan, H ;
du Toit, PD ;
van Aswegen, A ;
Lötter, MG ;
Herbst, CP ;
van der Walt, TN ;
Otto, AC .
MEDICAL PHYSICS, 2000, 27 (07) :1523-1534
[45]   Risk stratification with attenuation corrected stress Tc-99m sestamibi SPECT myocardial perfusion imaging in the absence of ECG-gating due to arrhythmias [J].
Sarkis B. Baghdasarian ;
Gavin L. Noble ;
Alan W. Ahlberg ;
Deborah Katten ;
Gary V. Heller .
Journal of Nuclear Cardiology, 2009, 16 :533-539
[46]   Quantitative regional cerebral blood flow measured by Tc-99m HMPAO SPECT in mood disorder [J].
Iidaka, T ;
Nakajima, T ;
Suzuki, Y ;
Okazaki, A ;
Maehara, T ;
Shiraishi, H .
PSYCHIATRY RESEARCH-NEUROIMAGING, 1997, 68 (2-3) :143-154
[47]   18F-Fluorocholine PET/CT, Tc-99m-MIBI and TC-99m-MDP SPECT/CT in Tertiary Hyperparathyroidism with Renal Osteodystrophy [J].
Ferrari, Cristina ;
Lavelli, Valentina ;
Santo, Giulia ;
Frugis, Maria Teresa ;
Iuele, Francesca ;
Rubini, Giuseppe ;
Sardaro, Angela .
DIAGNOSTICS, 2020, 10 (10)
[48]   Assessment of absolute Tc-99m tetrofosmin retention in the myocardium as an index of myocardial blood flow and coronary flow reserve by gated-SPECT/CT: a feasibility study [J].
Apostolopoulos, Dimitris J. ;
Kaspiri, Agaristi ;
Spyridonidis, Trifon ;
Patsouras, Nikolaos ;
Savvopoulos, Christos A. ;
Davlouros, Pericles ;
Vassilakos, Pavlos. J. ;
Alexopoulos, Dimitrios .
ANNALS OF NUCLEAR MEDICINE, 2015, 29 (07) :588-602
[49]   Tc-99m-HMPAO brain SPECT imaging in a case of repeated syncopal episodes associated with smoking [J].
Fukuda, H ;
Kitani, M ;
Omodani, H .
STROKE, 1997, 28 (07) :1461-1463
[50]   Prospective evaluation of malignant middle cerebral artery infarction with blood-brain barrier imaging using Tc-99m DTPA SPECT [J].
Lampl, Yair ;
Sadeh, Menachem ;
Lorberboym, Mordechai .
BRAIN RESEARCH, 2006, 1113 :194-199