CT Nonuniform Attenuation and TEW Scatter Corrections in Brain Tc-99m ECD SPECT

被引:9
作者
Farid, Karim [1 ]
Habert, Marie-Odile [2 ,3 ]
Martineau, Antoine [4 ]
Caillat-Vigneron, Nadine [1 ,5 ]
Sibon, Igor [6 ,7 ,8 ]
机构
[1] Hop Hotel Dieu, AP HP, Nucl Med Serv, F-75181 Paris, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Nucl Med Serv, F-75634 Paris, France
[3] Univ Paris 06, INSERM, UMR S 678, Paris, France
[4] St Louis Hosp, Dept Nucl Med, Paris, France
[5] Univ Paris 05, Paris, France
[6] Univ Bordeaux 2, F-33076 Bordeaux, France
[7] Univ Hosp Bordeaux, Bordeaux, France
[8] CNRS, UMR 5231, Bordeaux, France
关键词
Tc-99m ECD SPECT/CT; attenuation correction; Alzheimer disease; cerebral blood flow; CEREBRAL-BLOOD-FLOW; COMPUTED-TOMOGRAPHY; DISTRIBUTIONS; QUANTIFICATION; COMPENSATION; TRANSMISSION; VOLUNTEERS;
D O I
10.1097/RLU.0b013e318217544c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Perfusion brain single photon emission computed tomography (SPECT) is currently used to evaluate patients with cognitive impairments. Although widely available, it has been reported to be significantly less sensitive than F-18 FDG positron emission tomography. Optimization of SPECT parameters using nonuniform attenuation correction (NUAC) and scatter correction (SC) might improve the accuracy of the method. This study assessed the effect of x-ray CT-based NUAC and triple-energy window (TEW-SC) on brain SPECT compared with Chang-uniform (UAC). A total of 31 patients with memory complaints underwent Tc-99m ECD SPECT/CT. CT-NUAC + TEW-SC and Chang-UAC were applied and compared. The images were spatially normalized to a default SPECT template supplied with Statistical Parametric Mapping software (SPM2). A paired t test image was then reconstructed. Regional cerebral blood flow measurements were apparently reduced in the frontal white-matter and in the frontotemporal cortex when CT-NUAC + TEW-SC were used. These findings need to be considered when interpreting Tc-99m ECD SPECT after applying CT-AC + TEW-SC. Further prospective studies with clinical correlations are needed.
引用
收藏
页码:665 / 668
页数:4
相关论文
共 50 条
[31]   Dual-isotope (In-111/Tc-99m) SPECT noise and artifact reduction with an analytic attenuation correction method [J].
Penney, BC ;
Kao, CM ;
Pan, XC ;
Bidani, N .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) :733-739
[32]   Brain PET and technetium-99m-ECD SPECT imaging in Lhermitte-Duclos disease [J].
Ogasawara, K ;
Yasuda, S ;
Beppu, T ;
Kobayashi, M ;
Doi, M ;
Kuroda, K ;
Ogawa, A .
NEURORADIOLOGY, 2001, 43 (11) :993-996
[33]   Risk stratification with attenuation corrected stress Tc-99m sestamibi SPECT myocardial perfusion imaging in the absence of ECG-gating due to arrhythmias [J].
Baghdasarian, Sarkis B. ;
Noble, Gavin L. ;
Ahlberg, Alan W. ;
Katten, Deborah ;
Heller, Gary V. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (04) :533-539
[34]   Evaluation of the Effects of Chang's Attenuation Correction Technique on Simlar Transverse Views of Cold and Hot Regions in Tc-99m SPECT: A Phantom Study [J].
Sayed, I. S. ;
Harfiza, A. .
5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 :643-649
[35]   Assessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM) [J].
Vedaei, Faezeh ;
Asl, Alireza Kamali ;
Kalantari, Faraz ;
Ansari, Mojtaba ;
Ay, Mohammad Reza .
IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2011, 19 (02) :52-59
[36]   Tc-99m (methylene diphosphonate) SPECT quantitative imaging: Impact of attenuation map generation from SPECT-non-attenuation corrected and MR images on the diagnosis of bone metastasis [J].
Mostafapour, S. ;
Arabi, H. ;
Gholamiankhah, F. ;
Razavi-Ratki, S. K. ;
Parach, A. A. .
INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (02) :299-308
[37]   Risk stratification using line source attenuation correction with rest/stress Tc-99m sestamibi SPECT myocardial perfusion imaging [J].
Ardestani, Afrooz ;
Ahlberg, Alan W. ;
Katten, Deborah M. ;
Santilli, Krista ;
Polk, Donna M. ;
Bateman, Timothy M. ;
Heller, Gary V. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (01) :118-126
[38]   COMPARISON OF AM-241 AND TC-99M AS TRANSMISSION SOURCES FOR ATTENUATION CORRECTION OF TL-202 SPECT IMAGING OF THE HEART [J].
FICARO, EP ;
FESSLER, JA ;
ROGERS, WL ;
SCHWAIGER, M .
JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (04) :652-663
[39]   Risk stratification using line source attenuation correction with rest/stress Tc-99m sestamibi SPECT myocardial perfusion imaging [J].
Afrooz Ardestani ;
Alan W. Ahlberg ;
Deborah M. Katten ;
Krista Santilli ;
Donna M. Polk ;
Timothy M. Bateman ;
Gary V. Heller .
Journal of Nuclear Cardiology, 2014, 21 :118-126
[40]   Diagnostic performance of Tc-99m HMPAO SPECT for early and late onset Alzheimer's disease: a clinical evaluation of linearization correction [J].
Mitsumoto, Tatsuya ;
Ohya, Nobuyoshi ;
Ichimiya, Atsushi ;
Sakaguchi, Yuichi ;
Kiyota, Aya ;
Abe, Koichiro ;
Morishita, Junji ;
Sasaki, Masayuki .
ANNALS OF NUCLEAR MEDICINE, 2009, 23 (05) :487-495