CT Nonuniform Attenuation and TEW Scatter Corrections in Brain Tc-99m ECD SPECT

被引:9
作者
Farid, Karim [1 ]
Habert, Marie-Odile [2 ,3 ]
Martineau, Antoine [4 ]
Caillat-Vigneron, Nadine [1 ,5 ]
Sibon, Igor [6 ,7 ,8 ]
机构
[1] Hop Hotel Dieu, AP HP, Nucl Med Serv, F-75181 Paris, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Nucl Med Serv, F-75634 Paris, France
[3] Univ Paris 06, INSERM, UMR S 678, Paris, France
[4] St Louis Hosp, Dept Nucl Med, Paris, France
[5] Univ Paris 05, Paris, France
[6] Univ Bordeaux 2, F-33076 Bordeaux, France
[7] Univ Hosp Bordeaux, Bordeaux, France
[8] CNRS, UMR 5231, Bordeaux, France
关键词
Tc-99m ECD SPECT/CT; attenuation correction; Alzheimer disease; cerebral blood flow; CEREBRAL-BLOOD-FLOW; COMPUTED-TOMOGRAPHY; DISTRIBUTIONS; QUANTIFICATION; COMPENSATION; TRANSMISSION; VOLUNTEERS;
D O I
10.1097/RLU.0b013e318217544c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Perfusion brain single photon emission computed tomography (SPECT) is currently used to evaluate patients with cognitive impairments. Although widely available, it has been reported to be significantly less sensitive than F-18 FDG positron emission tomography. Optimization of SPECT parameters using nonuniform attenuation correction (NUAC) and scatter correction (SC) might improve the accuracy of the method. This study assessed the effect of x-ray CT-based NUAC and triple-energy window (TEW-SC) on brain SPECT compared with Chang-uniform (UAC). A total of 31 patients with memory complaints underwent Tc-99m ECD SPECT/CT. CT-NUAC + TEW-SC and Chang-UAC were applied and compared. The images were spatially normalized to a default SPECT template supplied with Statistical Parametric Mapping software (SPM2). A paired t test image was then reconstructed. Regional cerebral blood flow measurements were apparently reduced in the frontal white-matter and in the frontotemporal cortex when CT-NUAC + TEW-SC were used. These findings need to be considered when interpreting Tc-99m ECD SPECT after applying CT-AC + TEW-SC. Further prospective studies with clinical correlations are needed.
引用
收藏
页码:665 / 668
页数:4
相关论文
共 50 条
  • [21] Added value of attenuation-corrected Tc-99m tetrofosmin SPECT for the detection of myocardial viability: Comparison with FDG SPECT
    Riemer H. J. A. Slart
    Jeroen J. Bax
    Wim J. Sluiter
    Dirk J. van Veldhuisen
    Pieter L. Jager
    Journal of Nuclear Cardiology, 2004, 11 : 689 - 696
  • [22] Voxel-based analysis of Tc-99 m ECD brain perfusion SPECT in patients with normal pressure hydrocephalus
    Yoon, Bora
    Yang, Dong-Won
    Shim, Yong-Soo
    Chung, Sung-Woo
    Ahn, Kook-Jin
    Joo-Hyun, O.
    Kim, Sung-Hoon
    Sohn, Hyung-Sun
    Chung, Soo-Kyo
    Chung, Yong-An
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1377 - 1381
  • [23] STUDIES OF THE RETENTION MECHANISM OF THE BRAIN PERFUSION IMAGING AGENT TC-99M-BICISATE (TC-99M-ECD)
    WALOVITCH, RC
    CHEESMAN, EH
    MAHEU, LJ
    HALL, KM
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1994, 14 : S4 - S11
  • [24] CT-based attenuation and scatter correction compared with uniform attenuation correction in brain perfusion SPECT imaging for dementia
    Gillen, Rebecca
    Firbank, Michael J.
    Lloyd, Jim
    O'Brien, John T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (17) : 6775 - 6787
  • [25] CT-based attenuation correction versus prone imaging to decrease equivocal interpretations of rest/stress Tc-99m tetrofosmin SPECT MPI
    Dee Malkerneker
    Reuven Brenner
    William H. Martin
    Uchechukwu K. A. Sampson
    Irene D. Feurer
    Marvin W. Kronenberg
    Dominique Delbeke
    Journal of Nuclear Cardiology, 2007, 14 : 314 - 323
  • [26] CT-based attenuation correction versus prone imaging to decrease equivocal interpretations of rest/stress Tc-99m tetrofosmin SPECT MPI
    Malkerneker, Dee
    Brenner, Reuven
    Martin, William H.
    Sampson, Uchechukwu K. A.
    Feurer, Irene D.
    Kronenberg, Marvin W.
    Delbeke, Dominique
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (03) : 314 - 323
  • [27] Comparison of Chang's with Sorenson's attenuation correction method by varying linear attenuation coefficient values in Tc-99m SPECT imaging
    Sayed, Inayatullah Shah
    Zakaria, Ahmed
    Nik, Norhafiza
    MEDICAL IMAGING AND INFORMATICS, 2008, 4987 : 216 - +
  • [28] Optimization of attenuation and scatter corrections in sentinel lymph node scintigraphy using SPECT/CT systems
    Hiroto Yoneyama
    Hiroyuki Tsushima
    Masahisa Onoguchi
    Takahiro Konishi
    Kenichi Nakajima
    Shinro Matsuo
    Daiki Kayano
    Hiroshi Wakabayashi
    Anri Inaki
    Seigo Kinuya
    Annals of Nuclear Medicine, 2015, 29 : 248 - 255
  • [29] Optimization of attenuation and scatter corrections in sentinel lymph node scintigraphy using SPECT/CT systems
    Yoneyama, Hiroto
    Tsushima, Hiroyuki
    Onoguchi, Masahisa
    Konishi, Takahiro
    Nakajima, Kenichi
    Matsuo, Shinro
    Kayano, Daiki
    Wakabayashi, Hiroshi
    Inaki, Anri
    Kinuya, Seigo
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (03) : 248 - 255
  • [30] Impact of CT tube-voltage and bone density on the quantitative assessment of tracer uptake in Tc-99m bone SPECT/CT: A phantom study
    Hashizume, Kengo
    Ichikawa, Yasutaka
    Tomita, Yoya
    Sakuma, Hajime
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 18 - 22