CT Nonuniform Attenuation and TEW Scatter Corrections in Brain Tc-99m ECD SPECT

被引:9
|
作者
Farid, Karim [1 ]
Habert, Marie-Odile [2 ,3 ]
Martineau, Antoine [4 ]
Caillat-Vigneron, Nadine [1 ,5 ]
Sibon, Igor [6 ,7 ,8 ]
机构
[1] Hop Hotel Dieu, AP HP, Nucl Med Serv, F-75181 Paris, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Nucl Med Serv, F-75634 Paris, France
[3] Univ Paris 06, INSERM, UMR S 678, Paris, France
[4] St Louis Hosp, Dept Nucl Med, Paris, France
[5] Univ Paris 05, Paris, France
[6] Univ Bordeaux 2, F-33076 Bordeaux, France
[7] Univ Hosp Bordeaux, Bordeaux, France
[8] CNRS, UMR 5231, Bordeaux, France
关键词
Tc-99m ECD SPECT/CT; attenuation correction; Alzheimer disease; cerebral blood flow; CEREBRAL-BLOOD-FLOW; COMPUTED-TOMOGRAPHY; DISTRIBUTIONS; QUANTIFICATION; COMPENSATION; TRANSMISSION; VOLUNTEERS;
D O I
10.1097/RLU.0b013e318217544c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Perfusion brain single photon emission computed tomography (SPECT) is currently used to evaluate patients with cognitive impairments. Although widely available, it has been reported to be significantly less sensitive than F-18 FDG positron emission tomography. Optimization of SPECT parameters using nonuniform attenuation correction (NUAC) and scatter correction (SC) might improve the accuracy of the method. This study assessed the effect of x-ray CT-based NUAC and triple-energy window (TEW-SC) on brain SPECT compared with Chang-uniform (UAC). A total of 31 patients with memory complaints underwent Tc-99m ECD SPECT/CT. CT-NUAC + TEW-SC and Chang-UAC were applied and compared. The images were spatially normalized to a default SPECT template supplied with Statistical Parametric Mapping software (SPM2). A paired t test image was then reconstructed. Regional cerebral blood flow measurements were apparently reduced in the frontal white-matter and in the frontotemporal cortex when CT-NUAC + TEW-SC were used. These findings need to be considered when interpreting Tc-99m ECD SPECT after applying CT-AC + TEW-SC. Further prospective studies with clinical correlations are needed.
引用
收藏
页码:665 / 668
页数:4
相关论文
共 50 条
  • [1] Clinical Impact of Nonuniform CT-Based Attenuation Correction in Brain Perfusion SPECT/CT Using 99mTc-ECD
    Farid, Karim
    Petras, Slavomir
    Poullias, Xavier
    Caillat-Vigneron, Nadine
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (06) : E343 - E345
  • [2] Statistical parametric mapping demonstrates asymmetric uptake with Tc-99m ECD and Tc-99m HMPAO SPECT in normal brain
    Brinkmann, Benjamin H.
    Jones, David T.
    Stead, Matt
    Kazemi, Noojan
    O'Brien, Terence J.
    So, Elson L.
    Blumenfeld, Hal
    Mullan, Brian P.
    Worrell, Gregory A.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2012, 32 (01): : 190 - 198
  • [3] A method to correct myocardial SPECT with Tc-99m compounds for scatter and attenuation without transmission
    Kupferschlager, J
    Muller, B
    Schulz, G
    Kaiser, HJ
    Wagenknecht, G
    Bares, R
    Bull, U
    NUKLEARMEDIZIN, 1997, 36 (02) : 56 - 64
  • [4] TC-99M HMPAO BRAIN PERFUSION SPECT IN BRAIN-DEATH
    BONETTI, MG
    CIRITELLA, P
    VALLE, G
    PERRONE, E
    NEURORADIOLOGY, 1995, 37 (05) : 365 - 369
  • [5] Brain Single Photon Emission Computed Tomography With Tc-99m MIBI or Tc-99m ECD in Comparison to MRI in Multiple Sclerosis
    Assadi, Majid
    Salimipour, Hooman
    Seyedabadi, Mohammad
    Saberifard, Jamshid
    Javadi, Hamid
    Nabipour, Iraj
    Nemati, Reza
    CLINICAL NUCLEAR MEDICINE, 2010, 35 (09) : 682 - 686
  • [6] Depressive mood in pre-dialytic chronic kidney disease: Statistical parametric mapping analysis of Tc-99m ECD brain SPECT
    Song, Sang Heon
    Kwak, Ihm Soo
    Kim, Seong-Jang
    Kim, Yong-Ki
    Kim, In Joo
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2009, 173 (03) : 243 - 247
  • [7] Scatter and attenuation correction in technetium-99m brain SPECT
    Hashimoto, J
    Kubo, A
    Ogawa, K
    Amano, T
    Fukuuchi, Y
    Motomura, N
    Ichihara, T
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (01) : 157 - 162
  • [8] Tc-99m HMPAO-SPECT With CT Attenuation Correction Improves Detection of Epileptogenic Areas
    Farid, Karim
    Sibon, Igor
    Fernandez, Philippe
    Michel, Veronique
    Barret, Olivier
    Allard, Michele
    CLINICAL NUCLEAR MEDICINE, 2009, 34 (05) : 290 - 291
  • [9] Tc-99m HMPAO brain perfusion SPECT images in a patient with Todd's paralysis
    Ohta, H
    Nishimura, M
    Nii, M
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (08) : 618 - 619
  • [10] Increased cerebral blood flow in MELAS shown by Tc-99m HMPAO brain SPECT
    N. J. Peng
    R. S. Liu
    J. Y. Li
    D. G. Tsay
    K. W. Kong
    C. G. Kwok
    H. W. Strauss