CT Nonuniform Attenuation and TEW Scatter Corrections in Brain Tc-99m ECD SPECT

被引:9
作者
Farid, Karim [1 ]
Habert, Marie-Odile [2 ,3 ]
Martineau, Antoine [4 ]
Caillat-Vigneron, Nadine [1 ,5 ]
Sibon, Igor [6 ,7 ,8 ]
机构
[1] Hop Hotel Dieu, AP HP, Nucl Med Serv, F-75181 Paris, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Nucl Med Serv, F-75634 Paris, France
[3] Univ Paris 06, INSERM, UMR S 678, Paris, France
[4] St Louis Hosp, Dept Nucl Med, Paris, France
[5] Univ Paris 05, Paris, France
[6] Univ Bordeaux 2, F-33076 Bordeaux, France
[7] Univ Hosp Bordeaux, Bordeaux, France
[8] CNRS, UMR 5231, Bordeaux, France
关键词
Tc-99m ECD SPECT/CT; attenuation correction; Alzheimer disease; cerebral blood flow; CEREBRAL-BLOOD-FLOW; COMPUTED-TOMOGRAPHY; DISTRIBUTIONS; QUANTIFICATION; COMPENSATION; TRANSMISSION; VOLUNTEERS;
D O I
10.1097/RLU.0b013e318217544c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Perfusion brain single photon emission computed tomography (SPECT) is currently used to evaluate patients with cognitive impairments. Although widely available, it has been reported to be significantly less sensitive than F-18 FDG positron emission tomography. Optimization of SPECT parameters using nonuniform attenuation correction (NUAC) and scatter correction (SC) might improve the accuracy of the method. This study assessed the effect of x-ray CT-based NUAC and triple-energy window (TEW-SC) on brain SPECT compared with Chang-uniform (UAC). A total of 31 patients with memory complaints underwent Tc-99m ECD SPECT/CT. CT-NUAC + TEW-SC and Chang-UAC were applied and compared. The images were spatially normalized to a default SPECT template supplied with Statistical Parametric Mapping software (SPM2). A paired t test image was then reconstructed. Regional cerebral blood flow measurements were apparently reduced in the frontal white-matter and in the frontotemporal cortex when CT-NUAC + TEW-SC were used. These findings need to be considered when interpreting Tc-99m ECD SPECT after applying CT-AC + TEW-SC. Further prospective studies with clinical correlations are needed.
引用
收藏
页码:665 / 668
页数:4
相关论文
共 22 条
[1]   Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed Tomography [J].
Beekman, FJ ;
Kamphuis, C ;
King, MA ;
van Rijk, PP ;
Viergever, MA .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2001, 25 (02) :135-146
[2]   Tc-99m HMPAO-SPECT With CT Attenuation Correction Improves Detection of Epileptogenic Areas [J].
Farid, Karim ;
Sibon, Igor ;
Fernandez, Philippe ;
Michel, Veronique ;
Barret, Olivier ;
Allard, Michele .
CLINICAL NUCLEAR MEDICINE, 2009, 34 (05) :290-291
[3]   TC-99M ATTENUATION COEFFICIENTS IN WATER-FILLED PHANTOMS DETERMINED WITH GAMMA CAMERAS [J].
HARRIS, CC ;
GREER, KL ;
JASZCZAK, RJ ;
FLOYD, CE ;
FEARNOW, EC ;
COLEMAN, RE .
MEDICAL PHYSICS, 1984, 11 (05) :681-685
[4]  
Hayashi M, 2005, J NUCL MED TECHNOL, V33, P224
[5]  
ICHIHARA T, 1993, J NUCL MED, V34, P2216
[6]  
Iida H, 1998, J NUCL MED, V39, P181
[7]   Procedure Guideline for Brain Perfusion SPECT Using Tc-99m Radiopharmaceuticals 3.0 [J].
Juni, Jack E. ;
Waxman, Alan D. ;
Devous, Michael D., Sr. ;
Tikofsky, Ronald S. ;
Ichise, Masanori ;
Van Heertum, Ronald L. ;
Carretta, Robert F. ;
Chen, Charles C. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2009, 37 (03) :191-195
[8]   EANM procedure guideline for brain perfusion SPECT using 99mTc-labelled radiopharmaceuticals, version 2 [J].
Kapucu, Oezlem L. ;
Nobili, Flavio ;
Varrone, Andrea ;
Booij, Jan ;
Vander Borght, Thierry ;
Nagren, Kjell ;
Darcourt, Jacques ;
Tatsch, Klaus ;
Van Laere, Koen J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (12) :2093-2102
[9]  
KEMP BJ, 1992, J NUCL MED, V33, P1875
[10]   A method for attenuation and scatter correction of brain SPECT based on computed tomography images [J].
Larsson, A ;
Johansson, L ;
Sundström, T ;
Åhlström, KR .
NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (04) :411-420