Optimizing intrapulmonary perfluorocarbon distribution: Fluoroscopic comparison of mode of ventilation and body position

被引:6
作者
Bateman, ST [1 ]
Doctor, A
Price, B
Murphy, MA
Thompson, JE
Zurakowski, D
Taylor, GA
Arnold, JH
机构
[1] Childrens Hosp, Dept Anesthesia, Boston, MA 02115 USA
[2] Childrens Hosp, Dept Radiol, Boston, MA 02115 USA
[3] Childrens Hosp, Dept Biomed Engn, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Dept Anesthesia, Boston, MA 02115 USA
[5] Harvard Univ, Sch Med, Dept Radiol, Boston, MA 02115 USA
[6] Harvard Univ, Sch Med, Dept Biomed Engn, Boston, MA 02115 USA
关键词
partial liquid ventilation; acute respiratory distress syndrome; acute lung injury; perflubron; perfluorocarbon; high-frequency oscillatory ventilation; conventional mechanical ventilation; prone positioning;
D O I
10.1097/00003246-200103000-00024
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Partial liquid ventilation with the perfluorochemical, perflubron, has been shown to improve lung mechanics and enhance gas exchange in the treatment of severe acute lung injury. However, the most effective strategy to provide optimal intrapulmonary distribution of perflubron has not been fully accessed. The objective of this study was to examine the effect of body position (supine vs. rotational) and mode of ventilation (conventional mechanical Ventilation [CMV] vs. high-frequency oscillatory Ventilation [HFOV]) on perflubron distribution and oxygenation improvement. Design: Prospective, randomized, animal trial. Setting: Research laboratory at a university medical center. Subjects: Twenty healthy piglets (4.5-6.6 kg). Interventions: Subjects underwent repetitive saline lavage to achieve a uniform degree of lung injury and then were randomized to either CMV or were converted to HFOV. Within each ventilator group, animals were randomized to supine positioning (S) or rotational positioning with alternation between supine and prone position (R) during incremental dosing of three 5-mL/kg doses of perflubron. Measurements and Main Results: Arterial blood gas tensions, hemodynamic variables, and the oxygenation index were recorded after each dose of 5 mL/kg. Lateral cinefluoroscopic images after each dose were digitized for computer analysis of density. A density index was calculated for a 2-cm(2) window in three dorsal and three ventral lung regions. Uniformity of distribution was calculated by comparing the mean density among the six regions. Oxygenation improvements were compared between groups. There were no significant differences in hemodynamic variables or gas exchange after lung injury in the four groups. Rotational positioning produced significantly more uniform perflubron distribution during both CMV and HFOV. This effect was independent of the mode of ventilation. The mean ventral density index was affected by rotating position and HFOV mode of ventilation after 10 mL/kg of perflubron, and rotating position was affected only after 15 mL/kg of perflubron. There was a significant reduction in the oxygenation index from baseline to end lavage in both CMV groups, as well as all of the animals that were rotated. Conclusion: Perflubron is more uniformly dispersed when dosed in a rotational fashion with alternation between supine and prone position during incremental dosing. This effect is independent of mode of ventilation. There was no relationship between oxygenation improvements and nondependent perflubron distribution. CMV and rotating dosing both led to a significant decrease in the oxygenation index after a 15 mL/kg dose of perflubron. This information has important impact on the future development of dosing strategies and clinical trial design.
引用
收藏
页码:601 / 608
页数:8
相关论文
共 26 条
[1]   High-frequency oscillatory ventilation with partial liquid ventilation in a model of acute respiratory failure [J].
Baden, HP ;
Mellema, JD ;
Bratton, SL ;
ORourke, PP ;
Jackson, JC .
CRITICAL CARE MEDICINE, 1997, 25 (02) :299-302
[2]   SURVIVAL OF MAMMALS BREATHING ORGANIC LIQUIDS EQUILIBRATED WITH OXYGEN AT ATMOSPHERIC PRESSURE [J].
CLARK, LC ;
GOLLAN, F .
SCIENCE, 1966, 152 (3730) :1755-&
[3]   Concealed air leak associated with large tidal volumes in partial liquid ventilation [J].
Cox, PN ;
Frndova, H ;
Tan, PSK ;
Nakamura, T ;
Sakurai, KY ;
Middleton, W ;
Mazer, D ;
Bryan, AC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (03) :992-997
[4]   High-frequency oscillatory ventilation of the perfluorocarbon-filled lung: Preliminary results in an animal model of acute lung injury [J].
Doctor, A ;
Mazzoni, MC ;
DelBalzo, U ;
DiCanzio, J ;
Arnold, JH .
CRITICAL CARE MEDICINE, 1999, 27 (11) :2500-2507
[5]   Pulmonary blood flow distribution during partial liquid ventilation [J].
Doctor, A ;
Ibla, JC ;
Grenier, BM ;
Zurakowski, D ;
Ferretti, ML ;
Thompson, JE ;
Lillehei, CW ;
Arnold, JH .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (05) :1540-1550
[6]  
Doctor Allan, 1998, Pediatric Research, V43, p35A
[7]   PERFLUOROCARBON-ASSOCIATED GAS-EXCHANGE [J].
FUHRMAN, BP ;
PACZAN, PR ;
DEFRANCISIS, M .
CRITICAL CARE MEDICINE, 1991, 19 (05) :712-722
[8]  
Gauger PG, 1997, SURGERY, V122, P313, DOI 10.1016/S0039-6060(97)90023-4
[9]   Initial experience with partial liquid ventilation in pediatric patients with the acute respiratory distress syndrome [J].
Gauger, PG ;
Pranikoff, T ;
Schreiner, RJ ;
Moler, FW ;
Hirschl, RB .
CRITICAL CARE MEDICINE, 1996, 24 (01) :16-22
[10]   Partial liquid ventilation improves gas exchange and increases EELV in acute lung injury [J].
Gauger, PG ;
Overbeck, MC ;
Chambers, SD ;
Cailipan, CI ;
Hirschl, RB .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (05) :1566-1572