Monte Carlo simulation of x-ray emission by kilovolt electron bombardment

被引:64
作者
Acosta, E
Llovet, X
Coleoni, E
Riveros, JA
Salvat, F
机构
[1] Univ Nacl Cordoba, Fac Matemat Astron & Fis, RA-5000 Cordoba, Argentina
[2] Univ Barcelona, Serv Cientifico Tecn, E-08028 Barcelona, Spain
[3] Univ Barcelona, Soc Catalana Fis IEC, Fac Fis ECM, E-08028 Barcelona, Spain
关键词
D O I
10.1063/1.367473
中图分类号
O59 [应用物理学];
学科分类号
摘要
A physical model for the simulation of x-rap emission spectra from samples irradiated with kilovolt electron beams is proposed. Inner shell ionization by electron impact is described by means of total cross sections evaluated from an optical-data model. A double differential cross section is proposed for bremsstrahlung emission, which reproduces the radiative stopping powers derived from the partial wave calculations of Kissel, Quarles and Pratt [At. Data Nucl. Data Tables 28, 381 (1983)]. These ionization and radiative cross sections have been introduced into a general-purpose Monte Carlo code, which pel forms simulation of coupled electron and photon transport for arbitrary materials. To improve the efficiency of the simulation, interaction forcing, a variance reduction technique, has been applied for both ionizing collisions and radiative events. The reliability of simulated x-ray spectra is analyzed by comparing simulation results with electron probe measurements. (C) 1998 American Institute of Physics. [S0021-8979(98)01511-4].
引用
收藏
页码:6038 / 6049
页数:12
相关论文
共 50 条
[21]   Monte Carlo simulation of x-ray tube spectra with PENELOPE [J].
Jia, Pengxiang ;
Xie, Yaoqin ;
Bao, Shanglian .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 :503-506
[22]   Diagnostic x-ray dosimetry using Monte Carlo simulation [J].
Ioppolo, JL ;
Price, RI ;
Tuchyna, T ;
Buckley, CE .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10) :1707-1720
[23]   Monte Carlo simulation of x-ray spectra generated by kilo-electron-volt electrons [J].
Llovet, X ;
Sorbier, L ;
Campos, CS ;
Acosta, E ;
Salvat, F .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (07) :3844-3851
[25]   Monte Carlo simulation of x-ray spectra generated by kilo-electron-volt electrons [J].
Llovet, X. (xavier@giga.sct.ub.es), 1600, American Institute of Physics Inc. (93)
[26]   Monte Carlo simulation of particle-induced X-ray emission channeling spectra of GaAs crystals [J].
Al-Turany, M ;
Meyer, JD ;
Bethge, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 168 (03) :362-366
[27]   Monte Carlo simulation of characteristic x-ray emission from thick samples bombarded by kiloelectronvolt electrons [J].
Bote, D. ;
Llovet, X. ;
Salvat, F. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2008, 41 (10)
[28]   A source of kilovolt X-ray [J].
Frantel, Inc., 13847 Skyline Bld, Los Gatos, CA 95030, United States ;
不详 ;
不详 .
Microsystem Technologies, 1996, 2 (02) :79-82
[29]   Monte Carlo simulation of X-ray fluorescence and scattering tomography experiments [J].
Vincze, L ;
Janssens, K ;
Vekemans, B ;
Adams, F .
DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 :328-337
[30]   A Simulation Method for X-ray Pulsar Signal Based on Monte Carlo [J].
Jin, Jing ;
Liu, Yixiao ;
Li, Xiaoyu ;
Shen, Yi ;
Huang, Liangwei .
2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, :1937-1942