Influence of Spectroscopic Techniques on the Estimation of the Degree of Conversion of Bulk-fill Composites

被引:16
作者
Bolanos-Carmona, V [1 ]
Benavides-Reyes, C. [2 ]
Gonzalez-Lopez, S. [2 ]
Gonzalez-Rodriguez, P. [2 ]
Alvarez-Lloret, P. [3 ]
机构
[1] Univ Granada, Fac Dent, Integrated Pediat Dent, Granada, Spain
[2] Univ Granada, Fac Dent, Dept Operat Dent, Granada, Spain
[3] Univ Oviedo, Fac Geol, Dept Geol, Oviedo, Spain
关键词
RESIN-BASED COMPOSITES; POLYMERIZATION SHRINKAGE; MECHANICAL-PROPERTIES; POST-POLYMERIZATION; MONOMER CONVERSION; LIGHT TRANSMISSION; DENTAL COMPOSITES; BIS-GMA; STRESS; RAMAN;
D O I
10.2341/18-095-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the degree of conversion (DC) of different flowable and sculptable bulk-fill composites (BFC), at 0- and 4-mm depths from the surface, by Fourier transform infrared (FTIR), attenuated total reflection FTIR (ATR-FTIR), and FT-Raman spectroscopic techniques. Methods and Materials: Six BFC were investigated, including three sculptable composites (Admira Fusion [Voco], Aura Bulk Fill [SDI], and X-tra Fill [Voco]) and three flowable composites (Venus Bulk Fill [Heraeus], Filtek [3M], and X-tra Base [Voco]). Three molds of each composite were light cured as specified by the manufacturer. For each mold, slices corresponding to 0-mm (surface) and 4-mm depth were analyzed by spectroscopic techniques: ATR-FTIR, FTIR, and FT-Raman. The spectra of uncured composite material were used as an analytical control for background subtraction of the treated composite. The area and amplitude of the reference peaks (1607 and 1637 cm(-1)) were obtained to calculate the DC percentage at 0- and 4-mm depth. A Kruskal-Wallis nonparametric test was used for materials, and paired comparisons were made using Mann-Whitney nonparametric test. Wilcoxon's rank test was used for comparison between spectroscopic methods and between 0- and 4-mm depth in each composite. Significance was accepted at p<0.05. Results: FTIR showed significantly lower DC values, both in areas and amplitudes of the peaks, when compared with the results reported by different BFC. Differences between the surface and 4-mm depth were detected more precisely by FT-Raman. ATR-FTIR obtained DC values significantly higher than those obtained by FTIR. Conclusions: The vibrational spectroscopy method significantly influenced DC measurements of the flowable and sculptable BFC explored.
引用
收藏
页码:92 / 103
页数:12
相关论文
共 49 条
  • [1] Polymerization kinetics and impact of post polymerization on the Degree of Conversion of bulk-fill resin-composite at clinically relevant depth
    Al-Ahdal, Khold
    Ilie, Nicoleta
    Silikas, Nick
    Watts, David C.
    [J]. DENTAL MATERIALS, 2015, 31 (10) : 1207 - 1213
  • [2] Post-cure depth of cure of bulk fill dental resin-composites
    Alrahlah, A.
    Silikas, N.
    Watts, D. C.
    [J]. DENTAL MATERIALS, 2014, 30 (02) : 149 - 154
  • [3] Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals
    Alshali, Ruwaida Z.
    Silikas, Nick
    Satterthwaite, Julian D.
    [J]. DENTAL MATERIALS, 2013, 29 (09) : E213 - E217
  • [4] Effect of various visible light photoinitiators on the polymerization and color of light-activated resins
    Arikawa, Hiroyuki
    Takahashi, Hideo
    Kanie, Takahito
    Ban, Seiji
    [J]. DENTAL MATERIALS JOURNAL, 2009, 28 (04) : 454 - 460
  • [5] Bulk-Fill Resin Composites: Polymerization Contraction, Depth of Cure, and Gap Formation
    Benetti, A. R.
    Havndrup-Pedersen, C.
    Honore, D.
    Pedersen, M. K.
    Pallesen, U.
    [J]. OPERATIVE DENTISTRY, 2015, 40 (02) : 190 - 200
  • [6] Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites
    Bucuta, Stefan
    Ilie, Nicoleta
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (08) : 1991 - 2000
  • [7] Collares FM, 2014, BRAZ ORAL RES, V28, P9
  • [8] In vitro comparison of mechanical properties and degree of cure of bulk fill composites
    Czasch, Pascal
    Ilie, Nicoleta
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) : 227 - 235
  • [9] Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis
    Engelhardt, Frank
    Hahnel, Sebastian
    Preis, Verena
    Rosentritt, Martin
    [J]. CLINICAL ORAL INVESTIGATIONS, 2016, 20 (08) : 2123 - 2130
  • [10] Polymerization stress - Is it clinically meaningful?
    Ferracane, Jack L.
    Hilton, Thomas J.
    [J]. DENTAL MATERIALS, 2016, 32 (01) : 1 - 10