The association between component malalignment and post-operative pain following navigation-assisted total knee arthroplasty: results of a cohort/nested case-control study

被引:45
作者
Czurda, Thomas [1 ]
Fennema, Peter [2 ]
Baumgartner, Martin [3 ]
Ritschl, Peter [1 ]
机构
[1] Orthopad Krankenhaus Gersthof, A-1180 Vienna, Austria
[2] Smith & Nephew Orthopaed AG, CH-6343 Rotkreuz, Switzerland
[3] Hietzing Hosp, Dept Radiol, A-1130 Vienna, Austria
关键词
Knee arthroplasty; Navigation; Alignment; Post-operative pain; Nested case-control study; REPLACEMENT; ALIGNMENT; OUTCOMES; SURGERY;
D O I
10.1007/s00167-009-0990-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Previous studies have noted an adverse relationship between implant malalignment during total knee arthroplasty (TKA) and post-operative pain. Although some evidence exists indicating that computer-assisted surgical navigation for TKA can improve the accuracy of component alignment, its impact on clinical outcomes is currently unknown. The dual goals of the present cohort/nested case-control study were to (1) compare self-reported responses to the Western Ontario-McMaster Osteoarthritis Index (WOMAC) questionnaire between computer-assisted TKA (123 patients) using the imageless PiGalileo navigation system and conventional TKA (207 patients) [cohort analysis], and (2) to investigate a potential association between malalignment and post-operative pain in 19 painful knees and 19 asymptomatic knees obtained from the cohort analysis using matched sampling [nested case-control study]. In the cohort analysis, a relevant but non-significant (P = 0.06) difference in the occurrence of chronic pain was observed between the navigated (12%) and conventional arms (20%). Median post-operative WOMAC pain score was 100 (range, 50-100) in the conventional group and 100 (range, 65-100) in the navigated group. However, the Mann-Whitney test revealed a significant difference in favor of the navigated group (P = 0.01). In the nested case-control analysis, radiological outcomes and computer tomography (CT) measurements of femoral rotation were compared between the groups. The CT rotation measurements yielded evidence of a relationship between post-operative pain and incorrect rotational alignment of the femoral component of more than 3A degrees (OR: 7; 95% CI: 1.2-42; P = .033). In conclusion, there was no clinical benefit to computer-assisted navigation; however, a statistically significant relationship was observed between incorrect rotational alignment of the femoral component and symptoms of post-operative pain following TKA.
引用
收藏
页码:863 / 869
页数:7
相关论文
共 26 条
[1]  
Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
[2]   Navigated total knee replacement - A meta-analysis [J].
Bauwens, Kai ;
Matthes, Gerrit ;
Wich, Michael ;
Gebhard, Florian ;
Hanson, Beate ;
Ekkernkamp, Axel ;
Stengel, Dirk .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :261-269
[3]  
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[4]   Computer-assisted surgery: A wine before its time - In the affirmative [J].
Callaghan, John J. ;
Liu, Steve S. ;
Warth, Lucian C. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (04) :27-28
[5]   Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[6]   Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique [J].
Chin, PL ;
Yang, KY ;
Yeo, SJ ;
Lo, NN .
JOURNAL OF ARTHROPLASTY, 2005, 20 (05) :618-626
[7]   Hands-on robotic unicompartmental knee replacement - A prospective, randomised controlled study of the Acrobot system [J].
Cobb, J ;
Henckel, J ;
Gomes, P ;
Harris, S ;
Jakopec, M ;
Rodriguez y Baena, F ;
Barrett, A ;
Davies, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :188-197
[8]   Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288
[9]   Osteointegration and implant position after cementless total knee replacement [J].
Fuiko, R ;
Zembsch, A ;
Loyoddin, M ;
Ritschl, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (408) :201-208
[10]   Computer-assisted navigation increases precision of component placement in total knee arthroplasty [J].
Haaker, RG ;
Stockheim, M ;
Kamp, M ;
Proff, G ;
Breitenfelder, J ;
Ottersbach, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) :152-159