Increase in the Tibial Slope Reduces Wear after Medial Unicompartmental Fixed-Bearing Arthroplasty of the Knee

被引:8
作者
Weber, Patrick [1 ]
Schroeder, Christian [1 ]
Schwiesau, Jens [2 ]
Utzschneider, Sandra [1 ]
Steinbrueck, Arnd [1 ]
Pietschmann, Matthias F. [1 ]
Jansson, Volkmar [1 ]
Mueller, Peter E. [1 ]
机构
[1] Univ Munich, Univ Hosp, Dept Orthoped Surg Phys Med & Rehabil, D-81377 Munich, Germany
[2] Aesculap AG Res & Dev, D-78532 Tuttlingen, Germany
关键词
IN-VITRO WEAR; POSTERIOR SLOPE; IMPLANT; MOBILE; KINEMATICS;
D O I
10.1155/2015/736826
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction. Unicompartmental arthroplasty of the knee in patients with isolated medial osteoarthritis gives good results, but survival is inferior to that of total knee prosthesis. Knees may fail because positioning of the prosthesis has been suboptimal. The aim of this study was to investigate the influence of the tibial slope on the rate of wear of amedial fixed-bearing unicompartmental knee arthroplasty. Materials and Methods. We simulated wear on a medial fixed-bearing unicompartmental knee prosthesis (Univation) in vitro with a customised, four-station, and servohydraulic knee wear simulator, which exactly reproduced the walking cycle (International Organisation for Standardisation (ISO) 14243-1: 2002(E)). The medial prostheses were inserted with 3 different posterior tibial slopes: 0 degrees, 4 degrees, and 8 degrees (n = 3 in each group). Results. The wear rate decreased significantly between 0 degrees and 4 degrees slope from 10.4 (SD 0.62) mg/million cycles to 3.22 (SD 1.71) mg/million cycles. Increasing the tibial slope to 8 degrees did not significantly change the wear rate. Discussion. As an increase in the tibial slope reduced the wear rate in a fixed-bearing prosthesis, a higher tibial slope should be recommended. However, other factors that are influenced by the tibial slope (e.g., the tension of the ligament) must also be considered.
引用
收藏
页数:7
相关论文
共 29 条
[1]   Early failure of unicompartmental knee arthroplasty leading to revision [J].
Aleto, Thomas J. ;
Berend, Michael E. ;
Ritter, Merrill A. ;
Faris, Philip M. ;
Meneghini, R. Michael .
JOURNAL OF ARTHROPLASTY, 2008, 23 (02) :159-163
[2]  
Angibaud L., 2012, J BONE JOINT SUR S37, V94-B, P338
[3]  
[Anonymous], 2010, ANN REPORT
[4]   Friction of total hip replacements with different bearings and loading conditions [J].
Brockett, Claire ;
Williams, Sophie ;
Jin, Zhongmin ;
Isaac, Graham ;
Fisher, John .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 81B (02) :508-515
[5]  
Dalury DF, 2009, ORTHOPEDICS, V32, P470
[6]   In vitro study of inter-individual variation in posterior slope in the knee joint [J].
de Boer, Johannes J. ;
Blankevoort, Leendert ;
Kingma, Idsart ;
Vorster, Willie .
CLINICAL BIOMECHANICS, 2009, 24 (06) :488-492
[7]   Biotribology of alternative bearing materials for unicompartmental knee arthroplasty [J].
Grupp, Thomas M. ;
Utzschneider, Sandra ;
Schroeder, Christian ;
Schwiesau, Jens ;
Fritz, Bernhard ;
Maas, Allan ;
Bloemer, Wilhelm ;
Jansson, Volkmar .
ACTA BIOMATERIALIA, 2010, 6 (09) :3601-3610
[8]   The Effect of Oxidative Aging on the Wear Performance of Highly Crosslinked Polyethylene Knee Inserts under Conditions of Severe Malalignment [J].
Hermida, Juan C. ;
Fischler, Andrew ;
Colwell, Clifford W., Jr. ;
D'Lima, Darryl D. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (12) :1585-1590
[9]   Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty [J].
Hernigou, P ;
Deschamps, G .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (03) :506-511
[10]   UKA closely preserves natural knee kinematics in vitro [J].
Heyse, Thomas J. ;
El-Zayat, Bilal F. ;
De Corte, Ronny ;
Chevalier, Yan ;
Scheys, Lennart ;
Innocenti, Bernardo ;
Fuchs-Winkelmann, Susanne ;
Labey, Luc .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) :1902-1910