Macular and Retinal Nerve Fiber Layer Thickness Measurements in Normal Eyes With the Stratus OCT, the Cirrus HD-OCT, and the Topcon 3D OCT-1000

被引:45
作者
Huang, Jingjing [1 ]
Liu, Xing [1 ]
Wu, Ziqiang [2 ]
Guo, Xinxing [1 ]
Xu, Hongzhi [3 ]
Dustin, Laurie [4 ]
Sadda, Srinivas [5 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Guangdong, Peoples R China
[2] Ctr Adv Eye Care, Carson City, NV USA
[3] Yale Univ, Sch Publ Hlth, Div Biostat, New Haven, CT USA
[4] Univ So Calif, Keck Sch Med, Dept Prevent Med, Los Angeles, CA 90033 USA
[5] Doheny Eye Inst, Doheny Image Reading Ctr, Los Angeles, CA 90033 USA
基金
中国国家自然科学基金;
关键词
macular thickness; retinal nerve fiber layer thickness; optical coherence tomography; time-domain; fourier-domain; OPTICAL COHERENCE TOMOGRAPHY; TIME-DOMAIN; FOURIER-DOMAIN; REPRODUCIBILITY;
D O I
10.1097/IJG.0b013e3181d786f8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare retinal nerve fiber layer (RNFL) and macular thickness measurements using time-domain optical coherence tomography (TD OCT) and 2 Fourier-domain OCTs (FD OCT). Methods: Sixty eyes of 60 normal participants underwent eye examination followed by OCT evaluation with the time-domain Stratus OCT (Carl Zeiss Meditec, Inc. Dublin, CA) and 2 FD OCTs-the Cirrus HD-OCT (Carl Zeiss Meditec, Inc. Dublin, CA) and the 3D OCT-1000 (Topcon Corporation, Tokyo, Japan). Each patient was scanned 3 times on each machine by the same physician examiner. RNFL and macular thickness measurements were compared across the 3 devices using repeated measures analysis of variance (ANOVA) and multiple comparison t tests with Bonferroni adjustments. The coefficients of variation (CV) and the intraclass correlation coefficients were calculated to assess reproducibility. Bland-Altman plots were constructed to assess the level of agreement between every 2 OCTs. Results: All 3 machines revealed similar patterns of regional differences in RNFL and macular thicknesses. Macular thickness was consistently greatest on the Cirrus and lowest on the Stratus device. However, RNFL measurements were less consistent. The overall average RNFL thickness was 4 mu m greater on the Stratus than on the 3D OCT-1000, which was in turn 5 mu m greater than on the Cirrus device. Bland-Altman plots showed poor-to-moderate agreement in terms of macular and RNFL thickness measurements between each 2 of the OCT devices. Both FD OCTs provided more reproducible readings on macular measurements than the Stratus, as evidenced by the lower CV and higher intraclass correlation coefficients. However, RNFL measurements on the 2 FD OCTs were not necessarily more reproducible than those from the Stratus OCT. Conclusion: Thickness measurements are not interchangeable among different OCT devices because of the poor-to-moderate interdevice measurement agreement. FD instruments yield more reproducible macular but not RNFL thickness measurements.
引用
收藏
页码:118 / 125
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 1991, Ophthalmology, V98, P786
[2]   Inter-device Variability of the Stratus Optical Coherence Tomography [J].
Barkana, Yaniv ;
Burgansky-Eliash, Zvia ;
Gerber, Yariv ;
Melamed, Shlomo ;
Neudorfer, Meira ;
Avni, Isaac ;
Bartov, Elisha ;
Morad, Yair .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (02) :260-266
[3]   Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments [J].
Bourne, RRA ;
Medeiros, FA ;
Bowd, C ;
Jahanbakhsh, K ;
Zangwill, LM ;
Weinreb, RN .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) :1280-1285
[4]   Normal macular thickness measurements in healthy eyes using stratus optical coherence tomography [J].
Chan, A ;
Duker, JS ;
Ko, TH ;
Fujimoto, JG ;
Schuman, JS .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (02) :193-198
[5]   Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography in the Detection of Band Atrophy of the Optic Nerve [J].
Costa-Cunha, Luciana V. F. ;
Cunha, Leonardo P. ;
Malta, Roberto F. S. ;
Monteiro, Mario L. R. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (01) :56-63
[6]  
DURBIN M, 2007, RETINAL MEASUREMENTS
[7]   Variance between program versions in measuring optic nerve fiber layer thickness using optical coherence tomography [J].
Furuichi, M ;
Kashiwagi, K ;
Tsukahara, S .
OPHTHALMOLOGICA, 2002, 216 (06) :409-414
[8]   Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements [J].
Gonzalez-Garcia, Alberto O. ;
Vizzeri, Gianmarco ;
Bowd, Christopher ;
Medeiros, Felipe A. ;
Zangwill, Linda M. ;
Weinreb, Robert N. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :1067-1074
[9]   A comparison of retinal nerve fiber layer (RNFL) thickness obtained with frequency and time domain optical coherence tomography (OCT) [J].
Hood, Donald C. ;
Raza, Ali S. ;
Kay, Kristine Y. ;
Sandler, Shlomit F. ;
Xin, Daiyan ;
Ritch, Robert ;
Liebmann, Jeffrey M. .
OPTICS EXPRESS, 2009, 17 (05) :3997-4003
[10]   MACULAR THICKNESS MEASUREMENTS IN NORMAL EYES WITH TIME-DOMAIN AND FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY [J].
Huang, Jingjing ;
Liu, Xing ;
Wu, Ziqiang ;
Xiao, Hui ;
Dustin, Laurie ;
Sadda, Srinivas .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (07) :980-987