Radiation exposure benefit of a lead cap in invasive cardiology

被引:70
作者
Kuon, E
Birkel, J
Schmitt, M
Dahm, JB
机构
[1] Klin Fraenk Schweiz, Dept Cardiol, D-91320 Ebermannstadt, Germany
[2] Ernst Moritz Arndt Univ Greifswald, Dept Internal Med, Greifswald, Germany
关键词
D O I
10.1136/heart.89.10.1205
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Occupational head exposure to radiation in cardiologists may cause radiation induced cataracts and an increased risk of brain cancer. Objective: To determine the effectiveness of 0.5 mm lead equivalent caps, not previously used in invasive cardiology, in comparison with a 1.0 mm lead equivalent ceiling mounted lead glass screen. Design: An anthropomorphic Alderson-Rando phantom was used to represent the patient. Scatter entrance skin air kerma to the operator position (S-ESAK-O) was measured during fluoroscopy for all standard angulations and the S-ESAK-O per dose-area product (DAP) calculated, as applied to the phantom. Results: Measured mean (SD) left/right anterior oblique angulation ratios of S-ESAK-O without lead devices were 23.1 (10.1), and varied as a function of tube angulation, body height, and angle of incidence. S-ESAK-O/DAP decreased with incremental operator body height by 10 (3)% per 10 cm. A 1.0 mm lead glass shield reduced mean S-ESAK-O/DAP originating from coronary angiography from 1089 (764) to 54 (29) nSv/Gy x cm(2). A 0.5 mm lead cap was effective in lowering measured levels to 1.8 (1.1) nSv/Gy x cm(2). Both devices together enabled attenuation to 0.5 (0.1) nSv/Gy x cm(2). The most advantageous line of vision for protection of the operator's eyes was >60degrees rightward. Conclusions: Use of 0.5 mm lead caps proved highly effective, attenuating S-ESAK-O to 2.7 (2.0)x10(-3) of baseline, and to 1.2 (1.4)x10(-3) of baseline where there was an additional 1.0 mm lead glass shield. These results could vary according to the x ray systems used, catheterisation protocols, and correct use of radiation protection devices.
引用
收藏
页码:1205 / 1210
页数:6
相关论文
共 27 条
[1]   RADIATION EXPOSURE TO OPERATOR PERFORMING CARDIAC ANGIOGRAPHY WITH U-ARM SYSTEMS [J].
BALTER, S ;
SONES, FM ;
BRANCATO, R .
CIRCULATION, 1978, 58 (05) :925-932
[2]  
Bernardi G, 2000, CATHETER CARDIO INTE, V51, P1
[3]  
*CEC COUNC DIR, 1997, EURATOM AMTSBLATT L, V180, P22
[4]   Factors affecting patient radiation exposure during routine coronary angiography in a tertiary referral centre [J].
Clark, AL ;
Brennan, AG ;
Robertson, LJ ;
McArthur, JD .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (866) :184-189
[5]   Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures [J].
Cusma, JT ;
Bell, MR ;
Wondrow, MA ;
Taubel, JP ;
Holmes, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) :427-435
[6]   OPERATOR RADIATION EXPOSURE DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
DASH, H ;
LEAMAN, DM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (04) :725-728
[7]   Real-time quantification and display of skin radiation during coronary angiography and intervention [J].
den Boer, A ;
de Feijter, PJ ;
Serruys, PW ;
Roelandt, JRTC .
CIRCULATION, 2001, 104 (15) :1779-1784
[8]  
Finkelstein MM, 1998, CAN J CARDIOL, V14, P1385
[9]  
Folkerts KH, 1997, Z KARDIOL, V86, P258, DOI 10.1007/s003920050057
[10]   Patient radiation exposure during coronary angiography and intervention [J].
Fransson, SG ;
Persliden, J .
ACTA RADIOLOGICA, 2000, 41 (02) :142-144