Conduction disturbances following surgical aortic valve replacement with a rapid-deployment bioprosthesis

被引:26
作者
Coti, Iuliana [1 ]
Schukro, Christoph [2 ]
Drevinja, Fitim [1 ]
Haberl, Thomas [1 ]
Kaider, Alexandra [3 ]
Kocher, Alfred [1 ]
Laufer, Guenther [1 ]
Andreas, Martin [1 ]
机构
[1] Med Univ Vienna, Div Cardiac Surg, Dept Surg, Vienna, Austria
[2] Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Vienna, Austria
[3] Med Univ Vienna, Ctr Med Stat Informat & Intelligent Syst, Vienna, Austria
关键词
PERMANENT PACEMAKER IMPLANTATION; PROSPECTIVE MULTICENTER; RISK-FACTORS; STENOSIS;
D O I
10.1016/j.jtcvs.2020.01.083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The implantation of rapid-deployment aortic valves may interfere with the conduction system of the heart. This study evaluates the occurrence and predictive factors of conduction anomalies in patients undergoing surgical aortic valve replacement (SAVR) with a rapid-deployment balloon-expandable bio-prosthesis in a single-center, real-world experience. Methods: Between May 2010 and April 2019, 700 consecutive patients were included in a prospective, ongoing database with a longitudinal follow-up preoperatively, at discharge, and at 3 months, 1 year, 3 years, and 5 years postoperatively. Thirty-seven patients (5.3%) had a permanent pacemaker at baseline and were excluded from further analysis, leaving 663 patients for analysis. Assessment of conduction anomalies was performed by electrocardiography (ECG) monitoring and repeated 12-lead ECG during the hospital stay and at postoperative follow-ups. Results: Preoperatively, 126 patients (19.0%) presented with different conduction disturbances. New permanent pacemaker implantation (PPI) occurred in 61 patients during the first 14 days (cumulative incidence, 9.4%). The indication for PPI was complete atrioventricular block in 47 cases (77%). Preoperative conduction anomalies, such as right bundle branch block, as well as operative characteristics (concomitant procedures) were found to be independent predictors for new PPI. One-year survival was 98% in patients with new early PPI and 96% in those without new early PPI (P = .60). Conclusions: The PPI rate was in the range of previous reports for rapid-deployment prostheses. PPI did not have a significant influence on short- to intermediate-term survival. Case selection with exclusion of patients presenting with baseline conduction disturbances may decrease the rate of new PPIs after SAVR with rapid-deployment balloon-expandable bioprostheses.
引用
收藏
页码:803 / 811
页数:9
相关论文
共 24 条
[1]   Guidelines for reporting mortality and morbidity after cardiac valve interventions [J].
Akins, Cary W. ;
Miller, D. Craig ;
Turina, Marko I. ;
Kouchoukos, Nicholas T. ;
Blackstone, Eugene H. ;
Grunkemeier, Gary L. ;
Takkenberg, Johanna J. M. ;
David, Tirone E. ;
Butchart, Eric G. ;
Adams, David H. ;
Shahian, David M. ;
Hagl, Siegfried ;
Mayer, John E. ;
Lytle, Bruce W. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (04) :732-738
[2]   Intermediate-term outcome of 500 consecutive rapid-deployment surgical aortic valve procedures [J].
Andreas, Martin ;
Coti, Iuliana ;
Rosenhek, Raphael ;
Shabanian, Shiva ;
Mahr, Stephane ;
Uyanik-Uenal, Keziban ;
Wiedemann, Dominik ;
Binder, Thomas ;
Kocher, Alfred ;
Laufer, Guenther .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (03) :527-533
[3]   Conventional versus rapid-deployment aortic valve replacement: a single-centre comparison between the Edwards Magna valve and its rapid-deployment successor [J].
Andreas, Martin ;
Wallner, Stephanie ;
Habertheuer, Andreas ;
Rath, Claus ;
Schauperl, Martin ;
Binder, Thomas ;
Beitzke, Dietrich ;
Rosenhek, Raphael ;
Loewe, Christian ;
Wiedemann, Dominik ;
Kocher, Alfred ;
Laufer, Guenther .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (06) :799-805
[4]   Permanent pacemaker implantation following isolated aortic valve replacement in a large cohort of elderly patients with severe aortic stenosis [J].
Bagur, Rodrigo ;
Manazzoni, Juan Maria ;
Dumont, Eric ;
Doyle, Daniel ;
Perron, Jean ;
Dagenais, Francois ;
Mathieu, Patrick ;
Baillot, Richard ;
Charbonneau, Eric ;
Metras, Jacques ;
Mohammadi, Siamak ;
Cote, Melanie ;
Philippon, Francois ;
Voisine, Pierre ;
Rodes-Cabau, Josep .
HEART, 2011, 97 (20) :1687-1694
[5]   Minimally invasive aortic valve replacement with sutureless and rapid deployment valves: a report from an international registry (Sutureless and Rapid Deployment International Registry) [J].
Berretta, Paolo ;
Andreas, Martin ;
Carrel, Thierry P. ;
Solinas, Marco ;
Teoh, Kevin ;
Fischlein, Theodor ;
Santarpino, Giuseppe ;
Folliguet, Thierry ;
Villa, Emmanuel ;
Meuris, Bart ;
Mignosa, Carmelo ;
Martinelli, Gianluca ;
Misfeld, Martin ;
Glauber, Mattia ;
Kappert, Utz ;
Savini, Carlo ;
Shrestha, Malak ;
Phan, Kevin ;
Albertini, Alberto ;
Yan, Tristan ;
Di Eusanio, Marco .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (04) :793-799
[6]   Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trialaEuro [J].
Borger, Michael A. ;
Dohmen, Pascal M. ;
Knosalla, Christoph ;
Hammerschmidt, Robert ;
Merk, Denis R. ;
Richter, Markus ;
Doenst, Torsten ;
Conradi, Lenard ;
Treede, Hendrik ;
Moustafine, Vadim ;
Holzhey, David M. ;
Duhay, Francis ;
Strauch, Justus .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 50 (04) :713-720
[7]   Pledget-Armed Sutures Affect the Haemodynamic Performance of Biologic Aortic Valve Substitutes: A Preliminary Experimental and Computational Study [J].
Capelli, Claudio ;
Corsini, Chiara ;
Biscarini, Dario ;
Ruffini, Francesco ;
Migliavacca, Francesco ;
Kocher, Alfred ;
Laufer, Guenther ;
Taylor, Andrew M. ;
Schievano, Silvia ;
Andreas, Martin ;
Burriesci, Gaetano ;
Rath, Claus .
CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2017, 8 (01) :17-29
[8]   Long-Term Outcomes in Patients With New-Onset Persistent Left Bundle Branch Block Following TAVR [J].
Chamandi, Chekrallah ;
Barbanti, Marco ;
Munoz-Garcia, Antonio ;
Latib, Azeem ;
Nombela-Franco, Luis ;
Gutierrez-Ibanez, Enrique ;
Veiga-Fernandez, Gabriela ;
Cheema, Asim N. ;
Cruz-Gonzalez, Ignacio ;
Serra, Vicenc ;
Tamburino, Corrado ;
Mangieri, Antonio ;
Colombo, Antonio ;
Jimenez-Quevedo, Pilar ;
Elizaga, Jaime ;
Lee, Dae-Hyun ;
del Blanco, Bruno Garcia ;
Puri, Rishi ;
Cote, Melanie ;
Philippon, Francois ;
Rodes-Cabau, Josep .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (12) :1175-1184
[9]   Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR): early results from 3343 patients [J].
Di Eusanio, Marco ;
Phan, Kevin ;
Berretta, Paolo ;
Carrel, Thierry P. ;
Andreas, Martin ;
Santarpino, Giuseppe ;
Di Bartolomeo, Roberto ;
Folliguet, Thierry ;
Meuris, Bart ;
Mignosa, Carmelo ;
Martinelli, Gianluca ;
Misfeld, Martin ;
Glauber, Mattia ;
Kappert, Utz ;
Shrestha, Malak ;
Albertini, Alberto ;
Teoh, Kevin ;
Villa, Emmanuel ;
Yan, Tristan ;
Solinas, Marco .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (04) :768-773
[10]   Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement [J].
Erdogan, HB ;
Kayalar, N ;
Ardal, H ;
Omeroglu, SN ;
Kirali, K ;
Guler, M ;
Akinci, E ;
Yakut, C .
JOURNAL OF CARDIAC SURGERY, 2006, 21 (03) :211-215