Doppler Vital Signs Detection in the Presence of Large-Scale Random Body Movements

被引:100
作者
Lv, Qinyi [1 ]
Chen, Lei [2 ]
An, Kang [2 ]
Wang, Jun [2 ]
Li, Huan [1 ]
Ye, Dexin [1 ]
Huangfu, Jiangtao [1 ]
Li, Changzhi [3 ]
Ran, Lixin [1 ]
机构
[1] Zhejiang Univ, Lab Appl Res Electromagnet, Hangzhou 310027, Peoples R China
[2] Beijing Electromech Engn Inst, Beijing 100074, Peoples R China
[3] Texas Tech Univ, Dept Elect & Comp Engn, Lubbock, TX 79409 USA
关键词
Doppler radar; matched filter; polynomial fitting; random body movement (RBM); vital signs detection; MATCHED-FILTER; RADAR SYSTEM; CANCELLATION; COMPENSATION; MOTION; SENSOR;
D O I
10.1109/TMTT.2018.2852625
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Noncontact detection of human vital signs based on miniaturized Doppler radar systems (DRSs) can be widely used in healthcare and biomedical applications. Although significant progresses have been achieved, a reliable wireless vital signs detection in the presence of large-scale random human body movements remains a technical challenge. In this paper, based on a comprehensive use of the high-dynamic-range radar architecture and linearized Doppler phase demodulation algorithms, we further introduce matched filters to retrieve the respiration and heartbeat spectra completely concealed under the wideband noise floor caused by large-scale body movements. Along with an existing 5.8-GHz system, a single-board integrated DRS operating at 24 GHz was designed to verify the effectiveness of the used architecture and algorithms. Experimental results comply with the theoretical expectation. The obtained results imply the potential to implement practical bioradar systems for human noncontact vital signs detections.
引用
收藏
页码:4261 / 4270
页数:10
相关论文
共 28 条
[1]   Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier [J].
Chen, KM ;
Huang, Y ;
Zhang, JP ;
Norman, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (01) :105-114
[2]   Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring [J].
Droitcour, AD ;
Boric-Lubecke, O ;
Lubecke, VM ;
Lin, JS ;
Kovacs, GTA .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2004, 52 (03) :838-848
[3]   Wireless Hand Gesture Recognition Based on Continuous-Wave Doppler Radar Sensors [J].
Fan, Tenglong ;
Ma, Chao ;
Gu, Zhitao ;
Lv, Qinyi ;
Chen, Jialong ;
Ye, Dexin ;
Huangfu, Jiangtao ;
Sun, Yongzhi ;
Li, Changzhi ;
Ran, Lixin .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2016, 64 (11) :4012-4020
[4]   Event Recognition for Contactless Activity Monitoring Using Phase-Modulated Continuous Wave Radar [J].
Forouzanfar, Mohamad ;
Mabrouk, Mohamed ;
Rajan, Sreeraman ;
Bolic, Miodrag ;
Dajani, Hilmi R. ;
Groza, Voicu Z. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (02) :479-491
[5]   A Hybrid Radar-Camera Sensing System With Phase Compensation for Random Body Movement Cancellation in Doppler Vital Sign Detection [J].
Gu, Changzhan ;
Wang, Guochao ;
Li, Yiran ;
Inoue, Takao ;
Li, Changzhi .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (12) :4678-4688
[6]   Noncontact Accurate Measurement of Cardiopulmonary Activity Using a Compact Quadrature Doppler Radar Sensor [J].
Hu, Wei ;
Zhao, Zhangyan ;
Wang, Yunfeng ;
Zhang, Haiying ;
Lin, Fujiang .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (03) :725-735
[7]   A Review on Recent Progress of Portable Short-Range Noncontact Microwave Radar Systems [J].
Li, Changzhi ;
Peng, Zhengyu ;
Huang, Tien-Yu ;
Fan, Tenglong ;
Wang, Fu-Kang ;
Horng, Tzyy-Sheng ;
Munoz-Ferreras, Jose-Maria ;
Gomez-Garcia, Roberto ;
Ran, Lixin ;
Lin, Jenshan .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (05) :1692-1706
[8]   A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring [J].
Li, Changzhi ;
Lubecke, Victor M. ;
Boric-Lubecke, Olga ;
Lin, Jenshan .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (05) :2046-2060
[9]   Random Body Movement Cancellation in Doppler Radar Vital Sign Detection [J].
Li, Changzhi ;
Lin, Jenshan .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (12) :3143-3152
[10]   MICROWAVE SENSING OF PHYSIOLOGICAL MOVEMENT AND VOLUME CHANGE - A REVIEW [J].
LIN, JC .
BIOELECTROMAGNETICS, 1992, 13 (06) :557-565