Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device

被引:16
作者
Dimitriadis, Zisis [1 ]
Scholtz, Werner [1 ]
Ensminger, Stephan M. [2 ]
Piper, Cornelia [1 ]
Bitter, Thomas [1 ]
Wiemer, Marcus [3 ]
Vlachojannis, Marios [1 ]
Boergermann, Jochen [2 ]
Faber, Lothar [1 ]
Horstkotte, Dieter [1 ]
Gummert, Jan [2 ]
Scholtz, Smita [1 ]
机构
[1] Ruhr Univ Bochum, Clin Cardiol, Herz & Diabet Zentrum NRW, Bad Oeynhausen, Germany
[2] Ruhr Univ Bochum, Clin Thorac & Cardiovasc Surg, Herz & Diabet Zentrum NRW, Bad Oeynhausen, Germany
[3] Ruhr Univ Bochum, Johannes Wesling Klinikum Minden, Dept Cardiol & Crit Care Med, Minden, Germany
来源
PLOS ONE | 2017年 / 12卷 / 08期
关键词
AORTIC-VALVE IMPLANTATION; END-POINT DEFINITIONS; ACCESS SITE CLOSURE; ANEURYSM REPAIR; TRANSCATHETER; REPLACEMENT; MULTICENTER; STENOSIS; REGISTRY; OUTCOMES;
D O I
10.1371/journal.pone.0183658
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective Evaluation of the impact of the sheath diameter on vascular complications and mortality in transfemoral aortic valve implantation. Method Between 2012 and 2014, 183 patients underwent the procedure using a sheath diameter of 18-24 F. This collective was divided into two groups: group 1, with a sheath diameter of 18F (G1, n = 94), consisted of patients with 18F Medtronic Sentrant and 18 F Direct Flow sheaths, and group 2 with a sheath diameter of 19-24 F (G2, n = 89) consisted of patients with Edwards expandable e-sheath and Solopath sheaths. Perclose-Proglide (R) was used as a closure device in all patients. Results G1 had significantly more female patients (64.9% vs. 46.1% in G2, p = 0.01) and the average BMI was lower (26 +/- 4.5% vs. 27.4 +/- 4.7%, p = 0.03). There was no significant difference in the incidence of major and minor vascular complications (G1: 12.8% vs. G2: 12.4%, p = 0.9). 30-day mortality was similar in both groups (G1: 6.4 +/- 2.5% [95% CI: 0.88-0.98], G2: 3.7 +/- 1.9% [95% CI: 0.92-0.99]. The Kaplan Meier analysis of survival revealed no significant differences either. Conclusion The difference in sheath diameter had no effect on either incidence or severity of vascular complications. There was no impact on mortality either.
引用
收藏
页数:12
相关论文
共 38 条
[1]   Update on transcatheter aortic valve replacement [J].
Abdel-Wahab, Mohamed ;
El-Mawardy, Mohamed ;
Richardt, Gert .
TRENDS IN CARDIOVASCULAR MEDICINE, 2015, 25 (02) :154-161
[2]   Transcatheter aortic valve replacement: current perspectives and future implications [J].
Agarwal, Shikhar ;
Tuzcu, E. Murat ;
Krishnaswamy, Amar ;
Schoenhagen, Paul ;
Stewart, William J. ;
Svensson, Lars G. ;
Kapadia, Samir R. .
HEART, 2015, 101 (03) :169-177
[3]  
[Anonymous], EUR HEART J
[4]   Impact of low-profile sheaths on vascular complications during transfemoral transcatheter aortic valve replacement [J].
Barbanti, Marco ;
Binder, Ronald K. ;
Freeman, Melanie ;
Wood, David A. ;
Leipsic, Jonathon ;
Cheung, Anson ;
Ye, Jian ;
Tan, John ;
Toggweiler, Stefan ;
Yang, Tae-Hyun ;
Dvir, Danny ;
Maryniak, Kasia ;
Lauck, Sandra ;
Webb, John G. .
EUROINTERVENTION, 2013, 9 (08) :929-935
[5]   Comparison of vascular closure devices for access site closure after transfemoral aortic valve implantation [J].
Barbash, Israel M. ;
Barbanti, Marco ;
Webb, John ;
De Nicolas, Javier Molina-Martin ;
Abramowitz, Yigal ;
Latib, Azeem ;
Nguyen, Caroline ;
Deuschl, Florian ;
Segev, Amit ;
Sideris, Konstantinos ;
Buccheri, Sergio ;
Simonato, Matheus ;
Della Rosa, Francesco ;
Tamburino, Corrado ;
Jilaihawi, Hasan ;
Miyazaki, Tadashi ;
Himbert, Dominique ;
Schofer, Niklas ;
Guetta, Victor ;
Bleiziffer, Sabine ;
Tchetche, Didier ;
Imme, Sebastiano ;
Makkar, Raj R. ;
Vahanian, Alec ;
Treede, Hendrik ;
Lange, Ruediger ;
Colombo, Antonio ;
Dvir, Danny .
EUROPEAN HEART JOURNAL, 2015, 36 (47) :3370-3379
[6]   Expandable sheath for transfemoral transcatheter aortic valve replacement: Procedural outcomes and complications [J].
Borz, Bogdan ;
Durand, Eric ;
Tron, Christophe ;
Godin, Matthieu ;
Canville, Alexandre ;
Hauville, Camille ;
Cribier, Alain ;
Eltchaninoff, Helene .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (06) :E227-E232
[7]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[8]   Percutaneous Endovascular Aortic Aneurysm Repair: A Prospective Evaluation of Safety, Efficiency, and Risk Factors [J].
Eisenack, Markus ;
Umscheid, Thomas ;
Tessarek, Joerg ;
Torsello, Giovanni F. ;
Torsello, Giovanni B. .
JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (06) :708-713
[9]   Prospective analysis of 30-day safety and performance of transfemoral transcatheter aortic valve implantation with Edwards SAPIEN XT versus SAPIEN prostheses [J].
Eltchaninoff, Helene ;
Durand, Eric ;
Borz, Bogdan ;
Godin, Matthieu ;
Tron, Christophe ;
Litzler, Pierre-Yves ;
Bessou, Jean-Paul ;
Bejar, Karim ;
Fraccaro, Chiara ;
Sanchez-Giron, Carlos ;
Dacher, Jean-Nicolas ;
Bauer, Fabrice ;
Cribier, Alain .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (03) :132-140
[10]   Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry [J].
Eltchaninoff, Helene ;
Prat, Alain ;
Gilard, Martine ;
Leguerrier, Alain ;
Blanchard, Didier ;
Fournial, Gerard ;
Iung, Bernard ;
Donzeau-Gouge, Patrick ;
Tribouilloy, Christophe ;
Debrux, Jean-Louis ;
Pavie, Alain ;
Gueret, Pascal .
EUROPEAN HEART JOURNAL, 2011, 32 (02) :191-197