Radiation dose assessement on dual and 16 slices MDCT using Monte Carlo simulation

被引:0
|
作者
Mkimel, M. [1 ,2 ]
Mesradi, M. R. [1 ]
El Baydaoui, R. [1 ]
Toufique, Y. [1 ]
Halimi, A. [1 ]
Hilal, M. [1 ]
Saad, E. [1 ]
Hilali, A. [1 ]
机构
[1] Hassan 1st Univ, High Inst Hlth Sci, Lab Technol & Med Sci, Settat, Morocco
[2] Publ Hosp, Dept Radiol, Settat, Morocco
来源
2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) | 2018年
关键词
CTDI; GATE; MDCT; PMMA; effective dose; CONVERSION FACTORS; GATE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed Tomography Dose Index (CTDI) is an important factor to estimate effective dose using the conversion factors. In this work, we estimated CTDI with Monte Carlo simulation using the (GATE/GEANT4) code. Two PMMA phantom diameters, 16 cm and 32 cm, have been used to simulate, respectively, the patient's head and body. The simulation was made at various kVp and mAs levels for dual and 16 slices Multi Detector Computed Tomography MDCT. Experimental CTDI measurements were performed with a calibrated pencil ion chamber and the two PMMAs. the comparison results between the simulated, measured and displayed values show slight differences. Indeed, a difference of less than 4% is noticed for the 2 slices and less than 2% for the 16 slices. The effectiveness of our method shows that GATE can be used to optimize the effective dose to reduce radiological risks in CT clinical applications.
引用
收藏
页码:885 / 889
页数:5
相关论文
共 50 条
  • [21] New technique for effective dose estimation using Monte Carlo simulation for the patients undergoing radioiodine therapy
    Jokic, Vesna Spasic
    Kocovska, Marina Zdraveska
    MEASUREMENT, 2013, 46 (01) : 795 - 802
  • [22] Fetal Organ Dose Assessment during Chest CT Examination Using Monte Carlo/Gate Simulation
    Benameur, Y.
    Tahiri, M.
    Mkimel, M.
    El Baydaoui, R.
    El Hariri, B.
    Mesradi, M. R.
    Hilali, A.
    Saad, E.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2023, 20 (04) : 690 - 698
  • [23] Experimental characterization and Monte Carlo simulation of radiation dose in mammography by AGMS-DM plus and OSL nanoDot™ detectors
    Fathi, I.
    Mkimel, M.
    Halimi, A.
    El Baydaoui, R.
    Mesradi, M. R.
    Krim, M.
    El Rhazouani, O.
    Saad, E.
    Hilali, A.
    2019 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2019,
  • [24] Fetal Organ Dose Assessment during Chest CT Examination Using Monte Carlo/Gate Simulation
    Y. Benameur
    M. Tahiri
    M. Mkimel
    R. El Baydaoui
    B. El Hariri
    M.R. Mesradi
    A. Hilali
    E. Saad
    Physics of Particles and Nuclei Letters, 2023, 20 : 690 - 698
  • [25] The Effect of Magnification on the Image Quality and the Radiation Dose in X-ray Digital Mammography: a Monte Carlo Simulation Study
    Choi, Yu-Na
    Kim, Hee-Joung
    Park, Hye-Suk
    Lee, Chang-Lae
    Cho, Hyo-Min
    Lee, Seung-Wan
    Ryu, Hyun-Ju
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 57 (03) : 494 - 500
  • [26] Development of GATE Monte Carlo simulation for a dual-head gamma camera
    Mehdi Momennezhad
    Ramin Sadeghi
    Shahrokh Nasseri
    Radiological Physics and Technology, 2012, 5 (2) : 222 - 228
  • [27] Development of GATE Monte Carlo simulation for a dual-head gamma camera
    Momennezhad, Mehdi
    Sadeghi, Ramin
    Nasseri, Shahrokh
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2012, 5 (02) : 222 - 228
  • [28] Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
    Mohammadi, Gh. R. Fallah
    Alam, N. Riyahi
    Geraily, Gh.
    Paydar, R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (04): : 313 - 321
  • [29] Estimating a size-specific dose for helical head CT examinations using Monte Carlo simulation methods
    Hardy, Anthony J.
    Bostani, Maryam
    Hernandez, Andrew M.
    Zankl, Maria
    McCollough, Cynthia
    Cagnon, Chris
    Boone, John M.
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2019, 46 (02) : 902 - 912
  • [30] Dosimetry in contact and magnification mammography, using Monte Carlo simulation
    Koutalonis, M.
    Delis, H.
    Spyrou, G.
    Costaridou, L.
    Tzanakos, G.
    Panayiotakis, G.
    PROCEEDINGS OF THE 15TH IASTED INTERNATIONAL CONFERENCE ON APPLIED SIMULATION AND MODELLING, 2006, : 389 - +