Analysis and Design of Cable-Stayed Steel Columns Using the Stiffness Probe Method

被引:0
|
作者
Gurfinkel, German [1 ]
Krishnan, Sudarshan [2 ]
机构
[1] Univ Illinois, Struct Engn, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Illinois Sch Architecture, Struct, Urbana, IL USA
来源
ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION | 2017年 / 54卷 / 03期
关键词
analysis; behavior; buckling modes; eigenvectors; cable; (slackening; stays; optimum prestraining); columns; design; (ASD; LRFD); elastic stability; failure mode; numerical methods; residual tension; cross-arms; load; (applied; external); spring; (augmented; parallel; series); steel; stiffness probe; strength; (enhancement; nominal);
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The stiffness probe method (SPM) is a new numerical procedure that calculates buckling loads. SPM probes the local stiffness of a given structure at the point of application of a small transverse perturbation force as the applied load is increased. The local stiffness degrades from a maximum for an unloaded structure to zero at the buckling load. An artifice spring is added to the original structure that eventually absorbs the full perturbation force at a prescribed small deflection, thereby keeping structural deformations small as the buckling load is approached. As a result, using an indicator that approaches zero at buckling rather than having to rely on increasingly larger deflections at buckling as in conventional P-Delta methods, SPM ensures an accurate numerical result for the critical load. We use SPM herein to study the behavior of one and two cross-arm cable-stayed columns under applied load. A formula is given to calculate the minimum slenderness that justifies converting a tube into a cable-stayed column. Various factors such as cable prestrain, cable cross-sectional areas, and tiers of cross-arms affecting column strength are examined for a series of cable-stayed columns. We find that cable-stayed columns may buckle either in a one-lobe symmetrical mode or two-lobe anti-symmetrical mode, the latter case being contrary to conventional thinking. A design example for a given cable-stayed column using the AISC Specification is presented. The effect of optimum cable prestrain to enhance column buckling strengths is discussed. A strength enhancement ratio (SER) is defined that evaluates the additional column strength gained after transforming a given steel tube into a cable-stayed column.
引用
收藏
页码:195 / 209
页数:15
相关论文
共 50 条
  • [41] Ultimate behavior of steel cable-stayed bridges - II. Parametric study -
    Kim, Seungjun
    Won, Deok Hee
    Kang, Young Jong
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2016, 16 (02) : 625 - 636
  • [42] Multiscale fatigue damage evolution in orthotropic steel deck of cable-stayed bridges
    Cui, Chuang
    Xu, You-Lin
    Zhang, Qing-Hua
    ENGINEERING STRUCTURES, 2021, 237
  • [43] Feasibility of a 1,400 m Span Steel Cable-Stayed Bridge
    Nagai, Masatsugu
    Fujino, Yozo
    Yamaguchi, Hiroki
    Iwasaki, Eiji
    JOURNAL OF BRIDGE ENGINEERING, 2004, 9 (05) : 444 - 452
  • [44] Probabilistic optimal safety valuation based on stochastic finite element analysis of steel cable-stayed bridges
    Han, Sung-Ho
    Bang, Myung-Seok
    SMART STRUCTURES AND SYSTEMS, 2012, 10 (02) : 89 - 110
  • [45] Improved system buckling analysis of effective lengths of girder and tower members in steel cable-stayed bridges
    Yoo, Hoon
    Choi, Dong-Ho
    COMPUTERS & STRUCTURES, 2009, 87 (13-14) : 847 - 860
  • [46] A novel method for vehicle load detection in cable-stayed bridge using graph neural network
    Pham, Van-Thanh
    Son, Hye-Sook
    Kim, Cheol-Ho
    Jang, Yun
    Kim, Seung-Eock
    STEEL AND COMPOSITE STRUCTURES, 2023, 46 (06): : 731 - 744
  • [47] Seismic performance analysis of long-span cable-stayed bridges using stainless steel buckling-restrained braces
    Li, Xiaoli
    Guo, Yu
    Su, Shengkang
    Zou, Jina
    Wang, Dongsheng
    STRUCTURES, 2025, 75
  • [48] ANALYSIS OF TIME-DEPENDENT CHARACTERISTICS FOR CABLE STATE OF EXISTING CABLE-STAYED BRIDGE
    Huang, Juan
    Tang, Li-Qun
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 1122 - 1127
  • [49] System Reliability Analysis on the Cable-stayed Bridge Considering Cable Breakage and Resistance Degradation
    Yan B.
    Sun Y.
    Zou Q.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2017, 44 (09): : 10 - 16and40
  • [50] Coupled nonlinear and time-dependent analysis for long span cable-stayed bridges
    Chen, Changsong
    Ma, Yafei
    Yan, Donghuang
    Li, Zhilun
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2020, 16 (10) : 1416 - 1429