Objective. The evaluation of the long-term stability of ElectroCorticoGram (ECoG) signals is an important scientific question as new implantable recording devices can be used for medical purposes such as Brain-Computer Interface (BCI) or brain monitoring. Approach. The long-term clinical validation of wireless implantable multi-channel acquisition system for generic interface with neurons (WIMAGINE), a wireless 64-channel epidural ECoG recorder was investigated. The WIMAGINE device was implanted in two quadriplegic patients within the context of a BCI protocol. This study focused on the ECoG signal stability in two patients bilaterally implanted in June 2017 (P1) and in November 2019 (P2). Methods. The ECoG signal was recorded at rest prior to each BCI session resulting in a 32 month and in a 14 month follow-up for P1 and P2 respectively. State-of-the-art signal evaluation metrics such as root mean square (RMS), the band power (BP), the signal to noise ratio (SNR), the effective bandwidth (EBW) and the spectral edge frequency (SEF) were used to evaluate stability of signal over the implantation time course. The time-frequency maps obtained from task-related motor activations were also studied to investigate the long-term selectivity of the electrodes. Main results. Based on temporal linear regressions, we report a limited decrease of the signal average level (RMS), spectral distribution (BP) and SNR, and a remarkable steadiness of the EBW and SEF. Time-frequency maps obtained during motor imagery, showed a high level of discrimination 1 month after surgery and also after 2 years. Conclusions. The WIMAGINE epidural device showed high stability over time. The signal evaluation metrics of two quadriplegic patients during 32 months and 14 months respectively provide strong evidence that this wireless implant is well-suited for long-term ECoG recording. Significance. These findings are relevant for the future of implantable BCIs, and could benefit other patients with spinal cord injury, amyotrophic lateral sclerosis, neuromuscular diseases or drug-resistant epilepsy.
引用
收藏
页数:12
相关论文
共 50 条
[1]   Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration [J].
Ajiboye, A. Bolu ;
Willett, Francis R. ;
Young, Daniel R. ;
Memberg, William D. ;
Murphy, Brian A. ;
Miller, Jonathan P. ;
Walter, Benjamin L. ;
Sweet, Jennifer A. ;
Hoyen, Harry A. ;
Keith, Michael W. ;
Peckham, P. Hunter ;
Simeral, John D. ;
Donoghue, John P. ;
Hochberg, Leigh R. ;
Kirsch, Robert F. .
LANCET, 2017, 389 (10081) :1821-1830
[2]   Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates [J].
Barrese, James C. ;
Rao, Naveen ;
Paroo, Kaivon ;
Triebwasser, Corey ;
Vargas-Irwin, Carlos ;
Franquemont, Lachlan ;
Donoghue, John P. .
JOURNAL OF NEURAL ENGINEERING, 2013, 10 (06)
[3]   An exoskeleton controlled by an epidural wireless brain-machine interface in a tetraplegic patient: a proof-of-concept demonstration [J].
Benabid, Alim Louis ;
Costecalde, Thomas ;
Eliseyev, Andrey ;
Charvet, Guillaume ;
Verney, Alexandre ;
Karakas, Serpil ;
Foerster, Michael ;
Lambert, Aurelien ;
Moriniere, Boris ;
Abroug, Neil ;
Schaeffer, Marie-Caroline ;
Moly, Alexandre ;
Sauter-Starace, Fabien ;
Ratel, David ;
Moro, Cecile ;
Torres-Martinez, Napoleon ;
Langar, Lilia ;
Oddoux, Manuela ;
Polosan, Mircea ;
Pezzani, Stephane ;
Auboiroux, Vincent ;
Aksenova, Tetiana ;
Mestais, Corinne ;
Chabardes, Stephan .
LANCET NEUROLOGY, 2019, 18 (12) :1112-1122
[4]   Restoring cortical control of functional movement in a human with quadriplegia [J].
Bouton, Chad E. ;
Shaikhouni, Ammar ;
Annetta, Nicholas V. ;
Bockbrader, Marcia A. ;
Friedenberg, David A. ;
Nielson, Dylan M. ;
Sharma, Gaurav ;
Sederberg, Per B. ;
Glenn, Bradley C. ;
Mysiw, W. Jerry ;
Morgan, Austin G. ;
Deogaonkar, Milind ;
Rezai, Ali R. .
NATURE, 2016, 533 (7602) :247-+
[5]   EEG contribution to the diagnosis of baclofen overdose [J].
Boutte, C. ;
Vercueil, L. ;
Durand, M. ;
Vincent, F. ;
Alvarez, J. -C. .
NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2006, 36 (02) :85-89
[6]   Characterization of the effects of the human dura on macro- and micro-electrocorticographic recordings [J].
Bundy, David T. ;
Zellmer, Erik ;
Gaona, Charles M. ;
Sharma, Mohit ;
Szrama, Nicholas ;
Hacker, Carl ;
Freudenburg, Zachary V. ;
Daitch, Amy ;
Moran, Daniel W. ;
Leuthardt, Eric C. .
JOURNAL OF NEURAL ENGINEERING, 2014, 11 (01)
[7]   A SILICON-BASED, 3-DIMENSIONAL NEURAL INTERFACE - MANUFACTURING PROCESSES FOR AN INTRACORTICAL ELECTRODE ARRAY [J].
CAMPBELL, PK ;
JONES, KE ;
HUBER, RJ ;
HORCH, KW ;
NORMANN, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) :758-768
[8]   High-performance neuroprosthetic control by an individual with tetraplegia [J].
Collinger, Jennifer L. ;
Wodlinger, Brian ;
Downey, John E. ;
Wang, Wei ;
Tyler-Kabara, Elizabeth C. ;
Weber, Douglas J. ;
McMorland, Angus J. C. ;
Velliste, Meel ;
Boninger, Michael L. ;
Schwartz, Andrew B. .
LANCET, 2013, 381 (9866) :557-564
[9]   Prediction of seizure likelihood with a long-term, implanted seizure advisory system in patients with drug-resistant epilepsy: a first-in-man study [J].
Cook, Mark J. ;
O'Brien, Terence J. ;
Berkovic, Samuel F. ;
Murphy, Michael ;
Morokoff, Andrew ;
Fabinyi, Gavin ;
D'Souza, Wendyl ;
Yerra, Raju ;
Archer, John ;
Litewka, Lucas ;
Hosking, Sean ;
Lightfoot, Paul ;
Ruedebusch, Vanessa ;
Sheffield, W. Douglas ;
Snyder, David ;
Leyde, Kent ;
Himes, David .
LANCET NEUROLOGY, 2013, 12 (06) :563-571
[10]   Functional mapping of human sensorimotor cortex with electrocorticographic spectral analysis - II. Event-related synchronization in the gamma band [J].
Crone, NE ;
Miglioretti, DL ;
Gordon, B ;
Lesser, RP .
BRAIN, 1998, 121 :2301-2315